RABS20M TSC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

1 Version: B2103

2A, 1000V Fast Recovery Bridge Rectifier

FEATURES

  • Glass passivated chip junction
  • Ideal for automated placement
  • High surge current capability
  • UL Recognized file # E-326854
  • Moisture sensitivity level: level 1, per J-STD-020
  • RoHS Compliant
  • Halogen-free according to IEC 61249-2-21

APPLICATIONS

  • Switching mode power supply (SMPS)
  • Adapters
  • Lighting application MECHANICAL DATA
  • Case: ABS
  • Molding compound meets UL 94V-0 flammability rating
  • Terminal: Matte tin plated leads, solderable per J-STD-002
  • Meet JESD 201 class 1 whisker test
  • Polarity: As marked
  • Weight: 0.096g (approximately) KEY PARAMETERS PARAMETER VALUE UNIT IF 2 A VRRM 1000 V IFSM 50 A TJ MAX 150 °C Package ABS Configuration Quad ABS ABSOLUTE MAXIMUM RATINGS (TA = 25°C unless otherwise noted) PARAMETER SYMBOL RABS20M UNIT Marking code on the device RA20M Repetitive peak reverse voltage VRRM 1000 V Reverse voltage, total rms value VR(RMS) 700 V Forward current IF 2 A Surge peak forward current, single half sine- wave superimposed on rated load per diode t = 8.3ms IFSM 50 A t = 1.0ms 120 A Rating for fusing (t<8.3ms) I2t 10 A2s Junction temperature TJ -55 to +150 °C Storage temperature TSTG -55 to +150 °C

2 Version: B2103

Junction-to-lead thermal resistance RӨJL 39 °C/W Junction-to-ambient thermal resistance RӨJA 82 °C/W Junction-to-case thermal resistance RӨJC 24 °C/W Thermal Performance Note: Units mounted on PCB (5mm x 5mm Cu pad test board) ELECTRICAL SPECIFICATIONS (TA = 25°C unless otherwise noted) PARAMETER CONDITIONS SYMBOL TYP MAX UNIT Forward voltage per diode(1) IF = 1A, TJ = 25°C VF 1.06 - V IF = 2A, TJ = 25°C 1.16 1.30 V IF = 1A, TJ = 125°C 0.89 - V IF = 2A, TJ = 125°C 1.00 1.16 V Reverse current @ rated VR per diode(2) TJ = 25°C IR - 5 µA TJ = 125°C - 90 µA Junction capacitance per diode 1MHz, VR = 4.0V CJ 15 - pF Maximum reverse recovery time IF = 0.5A , IR = 1.0A Irr = 0.25A trr - 300 ns Notes: 1. Pulse test with PW = 0.3ms 2. Pulse test with PW = 30ms

ORDERING INFORMATION

ORDERING CODE PACKAGE PACKING RABS20M ABS 5,000 / Tape & Reel

3 Version: B2103

(TA = 25°C unless otherwise noted) Fig.1 Forward Current Derating Curve Fig.2 Typical Junction Capacitance Fig.3 Typical Reverse Characteristics Fig.4 Typical Forward Characteristics 0 25 50 75 100 125 150 100 1 10 100 f=1.0MHz Vsig=50mVp-p 0.01 0.1 100 1000 10 20 30 40 50 60 70 80 90 100 TJ=25°C TJ=125°C TJ=150°C 0.1 Pulse width 300μs 1% duty cycle TJ=25°C TJ=125°C TJ=-55°C TJ=150°C CAPACITANCE (pF) AMBIENT TEMPERATURE (°C) INSTANTANEOUS REVERSE CURRENT (μA ) PERCENT OF RATED PEAK REVERSE VOLTAGE (%) INSTANTANEOUS FORWARD CURRENT (A) (A) 0.001 0.01 0.1 Pulse width TJ=25°C TJ=125°C UF1DLW FORWARD VOLTAGE (V) AVERAGE FORWARD CURRENT (A) REVERSE VOLTAGE (V)

4 Version: B2103

PACKAGE OUTLINE DIMENSIONS ABS SUGGESTED PAD LAYOUT MARKING DIAGRAM P/N = Marking Code YW = Date Code F = Factory Code

5 Version: B2103

Specifications of the products displayed herein are subject to change without notice. TSC or anyone on its behalf, assumes no responsibility or liability for any errors or inaccuracies. Purchasers are solely responsible for the choice, selection, and use of TSC products and TSC assumes no liability for application assistance or the design of Purchasers’ products. Information contained herein is intended to provide a product description only. No license, express or implied, to any intellectual property rights is granted by this document. Except as provided in TSC’s terms and conditions of sale for such products, TSC assumes no liability whatsoever, and disclaims any express or implied warranty, relating to sale and/or use of TSC products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright, or other intellectual property right. The products shown herein are not designed for use in medical, life -saving, or life -sustaining applications. Customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify TSC for any damages resulting from such improper use or sale.