MODEL: R5T-YS R5T-YS SPECIFICATIONS ES-6121 Rev.8 Page 1/3 http://www.m-system.co.jp/ Remote I/O R5 Series 4 - 20 mA OUTPUT MODULE (screw terminal block) 137 (5.39) 18 (.71) (3.54) mm (inch) MODEL: R5T-YS[1][2]/A[3]
ORDERING INFORMATION
- Code number: R5T-YS[1][2]/A[3] Specify a code from below for each [1] through [3]. (e.g. R5T-YS1W/A/H/Q)
- Specify the specification for option code /Q (e.g. /C01/S01) [1] NO. OF CHANNELS 1: 1 2: 2 [2] COMMUNICATION MODE S: Single W: Dual OUTPUT HOLD /A: With output hold setting switch [3] OPTIONS (multiple selections) Load Resistance blank: ≤ 300 Ω /H: ≤ 600Ω (available only for 1-channel output type) Other Options blank: none /Q: Option other than the above (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating TERMINAL SCREW MATERIAL /S01: Stainless steel GENERAL SPECIFICATIONS Connection Internal bus: Via the Installation Base (model: R5-BS) Output: M3.5 screw terminal block (torque 0.8 N·m) Internal power: Via the base (model: R5-BS) Screw terminal: Nickel-plated steel (standard) or stainless steel Isolation: Output 1 to output 2 to internal bus or internal power Output hold: Setting of output hold or off for communication error with side DIP SW RUN indicator: Bi-color (red/green) LED; Red when the bus A operates normally; Green when the bus B operates normally; Amber when both buses operate normally. OUTPUT SPECIFICATIONS Output range: 4 – 20 mA DC Load resistance: 300 Ω max. (600 Ω max. with Option /H) INSTALLATION Operating temperature: -10 to +55°C (14 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: Installation Base (model: R5-BS) Weight: 110 g (0.24 lb) PERFORMANCE Conversion accuracy: ±0.1 % Data range: 0 – 10000 of the output range Data allocation: 1 (2 for 2-channel type) Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) With Option /H, ±0.02 %/°C (±0.01 %/°F) Response time: ≤ 0.2 sec. (0 – 90 %) Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 1500 V AC @ 1 minute (output 1 to output 2 to internal bus or internal power)
2000 V AC @ 1 minute (power input to FG; isolated on the
power supply module) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 RoHS Directive EN 50581
MODEL: R5T-YS R5T-YS SPECIFICATIONS ES-6121 Rev.8 Page 2/3 http://www.m-system.co.jp/ FUNCTIONS Output hold function: In normal conditions, the module outputs the signal from the preferred internal bus A. When an error is detected, the output is switched to the data from the internal bus B. If both are in error, when the DIP switch on the side panel is OFF, the module holds and output the last received data. When the DIP switch 1 is ON, the module holds and output -15 % of the selected range (approx. 1.6 mA). Either internal bus A or bus B becomes normal, output recovers. EXTERNAL VIEW RUN ON 1 2 3 4 5 6 7 8 ■ SIDE VIEW ■ FRONT VIEW Output Hold or Output OFF RUN LED Function EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) TERMINAL COVER 6–M3.5 TERMINAL SCREWS 8.2 (.32) 7.2 (.28) LOCKING CLAMP 90 (3.54) 5.6 (.22) 18 (.71) POSITIONING GUIDE
MODEL: R5T-YS R5T-YS SPECIFICATIONS ES-6121 Rev.8 Page 3/3 http://www.m-system.co.jp/ SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM INTERNAL POWER INTERNAL BUS A *INTERNAL BUS B Control Circuit Isolation Isolation Communication Circuit BUS CONNECTOR * For dual redundant communication. Note: The section enclosed by broken line is with 2-ch. option. OUTPUT 1 OUTPUT 2 RUN LED DIP SW Specifications are subject to change without notice.