XR26336N HOLLINGSWORTH | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 26
Technical content
26/24 Rings CMA Range 202-320 Barrel Inside Diameter .027"/.686 mm Material: COPPER Thickness: .023"/.584 mm Insulated (Yellow Nylon) Basic Dimensions Non-Insulated Insul. Dia. .092" / 2.33 mm Stud W W C C Funnel E E L L Size In. mm In. mm NIT FIIG In. mm In. mm Hand Tool H74 H7B & H53 22/16* Rings CMA Range 509-3260 Barrel Inside Diameter .059"/ 1.5 mm Material: COPPER Thickness: .030"/.762 mm Stud W W C C NIT E E L L Funnel E E L L Funnel E E L L Hand Tool H4A H4A H7B & H53** H7B & H53 zy zy * 22-16 Rings are marked 22-18 in accordance with AS7928 zy zy ** H53 for short barrel, H53L for long barrel www.hollingsworth.com 800.638.8376 Most terminals available tape mounted. Consult Electro-Term/Hollingsworth with your specifications.
22/16 Spades CMA Range 509-3260 Barrel Inside Diameter .059"/ 1.5 mm Material: COPPER Thickness: .030"/.762 mm Stud W W C C NIT E E L L Funnel E E L L Funnel E E L L Hand Tool H4A H4A H7B & H53 H7B & H53 zy zy zy zy * H53 for short barrel, H53L for long barrel 22/16 Block Spades CMA Range 509-3260 Barrel Inside Diameter .059"/ 1.5 mm Material: COPPER Thickness: .030"/.762 mm Stud W W C C NIT E E L L Funnel E E L L Funnel E E L L Hand Tool H4A H4A H7B & H53 H7B & H53 zy zy zy zy * H53 for short barrel, H53L for long barrel 22/16 Spring Spades CMA Range 509-3260 Barrel Inside Diameter .059"/ 1.5 mm Material: COPPER ALLOY Thickness: .030"/.762 mm Stud W W C C NIT E E L L Funnel E E L L Funnel E E L L Hand Tool H4A H4A H7B & H53 H7B & H53 zy zy zy zy 22/16 Mini Spring Spades CMA Range 509-3260 Barrel Inside Diameter .059"/ 1.5 mm Material: COPPER ALLOY Thickness: .030"/.762 mm Stud W W C C NIT E E L L Funnel E E L L Funnel E E L L Hand Tool H4A H4A H7B & H53 H7B & H53 zy zy zy zy Most terminals available tape mounted. Consult Electro-Term/Hollingsworth with your specifications. 800.638.8376 www.hollingsworth.com
www.hollingsworth.com 800.638.8376 Most terminals available tape mounted. Consult Electro-Term/Hollingsworth with your specifications. 22/16 Flanged Spades CMA Range 509-3260 Barrel Inside Diameter .059"/ 1.5 mm Material: COPPER Thickness: .030"/.762 mm Stud W W C C NIT E E L L Funnel E E L L Funnel E E L L Hand Tool H4A H4A H7B & H53* H7B & H53 zy zy zy zy * H53 for short barrel, H53L for long barrel 20/16 Rings, Heavy Duty CMA Range 1290-3260 Barrel Inside Diameter .065"/ 1.65 mm Material: COPPER Thickness: .040"/1.02 mm Basic Dimensions Non-Insulated Stud W W C C NIT E E L L Size In. mm In. mm Brazed In. mm In. mm Hand Tool H4A zy 16/14 Rings CMA Range 2050-5180 Barrel Inside Diameter .085"/ 2.16 mm Material: COPPER Thickness: .032"/.813 mm Stud W W C C NIT E E L L Funnel E E L L Funnel E E L L Hand Tool H4A H4A H7B & H53* H7B & H53 zy zy zy zy * H53 for short barrel, H53L for long barrel
16/14 Spades CMA Range 2050-5180 Barrel Inside Diameter .085"/ 2.16 mm Material: COPPER Thickness: .032"/.813 mm Stud W W C C NIT E E L L Funnel E E L L Funnel E E L L Hand Tool H4A H4A H7B & H53* H7B & H53 zy zy zy zy * H53 for short barrel, H53L for long barrel 16/14 Block Spades CMA Range 2050-5180 Barrel Inside Diameter .085"/ 2.16 mm Material: COPPER Thickness: .030"/.762 mm Stud W W C C NIT E E L L Funnel E E L L Funnel E E L L Hand Tool H4A H4A H7B & H53* H7B & H53 zy zy zy zy * H53 for short barrel, H53L for long barrel 16/14 Spring Spades CMA Range 2050-5180 Barrel Inside Diameter .085"/ 2.16 mm Material: COPPER ALLOY Thickness: .030"/.762 mm Stud W W C C NIT E E L L Funnel E E L L Funnel E E L L Hand Tool H4A H4A H7B & H53 H7B & H53 zy zy zy zy 16/14 Mini Spring Spades CMA Range 2050-5180 Barrel Inside Diameter .085"/ 2.16 mm Material: COPPER ALLOY Thickness: .030"/.762 mm Stud W W C C NIT E E L L Funnel E E L L Funnel E E L L Hand Tool H4A H4A H7B & H53 H7B & H53 zy zy zy zy Most terminals available tape mounted. Consult Electro
16/14 Flanged Spades CMA Range 2050-5180 Barrel Inside Diameter .085"/ 2.16 mm Material: COPPER Thickness: .032"/.813 mm Stud W W C C NIT E E L L Funnel E E L L Funnel E E L L Hand Tool H4A H4A H7B & H53 H7B & H53 zy zy zy zy 16/14 Rings - Heavy Duty CMA Range 2050-5180 Barrel Inside Diameter .110"/ 2.79 mm Material: COPPER Thickness: .049"/1.24 mm Stud W W C C NIT E E L L Funnel E E L L Funnel E E L L Hand Tool H4A H4A H6E & H53 H6E & H53 zy zy zy ▲ For Brazed Barrel, zy change suffix to BF 16/14 Rings - Heavy Duty (Railroad Terminals) CMA Range 2050-5180 Barrel Inside Diameter .110"/ 2.79 mm Material: COPPER Thickness: .049" / 1.24 mm Stud W W C C NIT E E L L Funnel E E L L Funnel E E L L Hand Tool H4A H4A H6E & H53 H6E & H53 zy zy zy zy 14/12 Rings CMA Range 3260-8230 Barrel Inside Diameter .094"/ 2.39 mm Material: COPPER Thickness: .040" / 1.02 mm Basic Dimensions Non-Insulated Stud W W C C NIT E E L L Size In. mm In. mm Brazed In. mm In. mm Hand Tool H4A zy www.hollingsworth.com 800.638.8376 Most terminals available tape mounted. Consult Electro-Term/Hollingsworth with your specifications.
Most terminals available tape mounted. Consult Electro 12/10 Rings CMA Range 5180-13,100 Barrel Inside Diameter .129"/ 3.27 mm Material: COPPER Thickness: .040"/1.02 mm Stud W W C C NIT E E L L Funnel E E L L Funnel E E L L Hand Tool H4A H4A H6E & H53 H6E & H53 zy zy zy zy 12/10 Spades CMA Range 5180-13,100 Barrel Inside Diameter .129"/ 3.27 mm Material: COPPER Thickness: .040"/1.02 mm Stud W W C C NIT E E L L Funnel E E L L Funnel E E L L Hand Tool H4A H4A H6E & H53 H6E & H53 zy zy zy zy 12/10 Spring Spades CMA Range 5180-13,100 Barrel Inside Diameter .129"/ 3.27 mm Material: COPPER ALLOY Thickness: .040" / 1.02 mm Stud W W C C NIT E E L L Funnel E E L L Funnel E E L L Hand Tool H4A H4A H6E & H53 H6E & H53 zy zy zy zy 12/10 Mini Spring Spades CMA Range 5180-13,100 Barrel Inside Diameter .129"/ 3.27 mm Material: COPPER ALLOY Thickness: .040" / 1.02 mm Stud W W C C NIT E E L L Funnel E E L L Funnel E E L L Hand Tool H4A H4A H6E & H53 H6E & H53 zy zy zy zy
12/10 Block Spades CMA Range 5180-13,1000 Barrel Inside Diameter .129"/ 3.27 mm Material: COPPER Thickness: .040"/1.02 mm Stud W W C C NIT E E L L Funnel E E L L Funnel E E L L Hand Tool H4A H4A H6E & H53 H6E & H53 zy zy zy zy 12/10 Flanged Spades CMA Range 5180-13,1000 Barrel Inside Diameter .129"/ 3.27 mm Material: COPPER Thickness: .040"/1.02 mm Stud W W C C NIT E E L L Funnel E E L L Funnel E E L L Hand Tool H4A H4A H6E & H53 H6E & H53 zy zy zy zy 12/10 Hooks CMA Range 5180-13,1000 Barrel Inside Diameter .129"/ 3.27 mm Material: COPPER Thickness: .040"/1.02 mm Stud W W C C NIT E E L L Funnel E E L L Funnel E E L L Hand Tool H4A H4A H6E & H53 H6E & H53 zy zy zy zy 12/10 Rings - Railroad Terminals CMA Range 5180-13,1000 Barrel Inside Diameter .129"/ 3.27 mm Material: COPPER Thickness: .040"/1.02 mm Stud W W C C NIT E E L L Funnel E E L L Funnel E E L L Hand Tool H4A H4A H6E & H53 H76E & H53 zy zy zy zy www.hollingsworth.com 800.638.8376 Most terminals available tape mounted. Consult Electro-Term/Hollingsworth with your specifications.
Material: COPPER Non-Insulated Wire CMA NIT ID ID OD OD L L NIT ID ID OD OD L L Hand Tool H4A H4A H4A y y ** with sight hole * Extended Flare Model also available – B1819S-EF Insulated (Nylon) Wire CMA FIT ID ID L L FIT ID ID L L Insul. Dia. Insul. Hand Tool Hand Tool See Above y y
- UL listed Insulated Flared (Vinyl) Wire CMA FIT FIT Flared ID ID L L Insul. Dia. Insul. Hand Tool Range Range Flared Brazed In. mm In. mm In. mm Color H270 Die Hand Tool See Above y y
- UL listed Most terminals available tape mounted. Consult Electro
26/10 Window Butt Connectors Material: COPPER Insulated (Nylon) Wire CMA Inside Barrel Dia. Insul. Insul. Dia. L L Hand Range Range In. mm FIIG Color In. mm In. mm Tool ▲ Not Brazed Step Down Butt Connectors Material: COPPER Non-Insulated Insulated (Nylon) Insulated (Vinyl) Range Range Brazed In. mm Tool Color FIT In. mm Flared In. mm In. mm Tool y y y l When ordering tape mounted Step Down Butt Connectors, indicate which end (wire size) is to be exposed for crimping. 26/10 Parallels Material: COPPER Non-Insulated Insulated (Nylon) Insulated (Vinyl) FIT Wire NIT ID ID OD OD L L Hand FIT Insul. Dia. FIT Flared L L Insul. Hand y y • P4019 Not UL or CSA listed y y y y Double Male Tab Single Female Slip-On Material: Brass Thickness: .32”/.813 mm Dimensions L L WW WW D D E E H H W W U U N N 41B 41B is unplated; for electro-tin plated part, specify 43B. www.hollingsworth.com 800.638.8376 Most terminals available tape mounted. Consult Electro-Term/Hollingsworth with your specifications.
22/18 • 16/14 • 12/10 Fully Insulated Nylon Couplers Material: BRASS Wire NEMA W W L L H H Insul. Dia. Hand Mat. Thickness CMA yz 22/18 Fully Insulated Slip-Ons (FISO) Barrel Inside Diameter CMA Range 509-2050 .064"/ 1.63 mm – .110 Series .057”/1.45 mm – All Others Insulated (Vinyl) NEMA W W L L H H FITS FIT Hand Funnel Hand TAB In. mm In. mm In. mm TAB Flared Tool FIIG Tool zy zy * Locator Blade 13-023 to be ordered in addition to Hand Tool 16/14 Fully Insulated Slip-Ons (FISO) Barrel Inside Diameter CMA Range 2050-5180 .064"/ 1.63 mm – .110 Series FISO FIT .081”/2.06 mm – All Others Series FISO FIT .079”/2.01 mm -- All FISO FIIG NEMA W W L L H H FITS FIT Hand Funnel Hand TAB In. mm In. mm In. mm TAB Flared Tool FIIG Tool zy * Special Order zy Locator Blade 13-023 to be ordered in addition to Hand Tool 12/10 Fully Insulated Slip-Ons (FISO) CMA Range 5180-13100 Barrel Inside Diameter .129"/ 3.27 mm Material: BRASS Thickness: .018" / .457 mm Basic Dimensions Insulated (Vinyl) Insul. Dia. .239" / 6.07mm NEMA W W L L H H FITS Funnel Hand TAB In. mm In. mm In. mm TAB FIIG Tool zy UL Listed for 12 AWG only Most terminals available tape mounted. Consult Electro-Term/Hollingsworth with your specifications. 800.638.8376 www.hollingsworth.com Mating .110 series tab Dimensions type A Dimensions type B
Basic Dimensions Non-Insulated NEMA W W T T E E B B FITS L L Hand L L Hand zy * Special Order zy NEMA W W T T E E B B FITS FIT L L Hand Funnel L L Hand zy * Special Order zy Locator Blade 13-023 to be ordered in addition to Hand Tool. 22/18 Male Slip-Ons Barrel Inside Diameter Basic Dimensions Non-Insulated NEMA C C E E B B FITS L L Hand L L Hand zy Not UL Listed zy * Special Order Basic Dimensions Insulated (Red Vinyl) Insulated (Red Nylon) NEMA C C E E B B FITS Funnel Insul. Dia. L L Hand Funnel Insul. Dia. L L Hand zy zy * Special Order Mating .110 series tab Dimensions type A Dimensions type B www.hollingsworth.com 800.638.8376 Most terminals available tape mounted. Consult Electro-Term/Hollingsworth with your specifications.
16/14 Female Slip-Ons Barrel Inside Diameter Basic Dimensions Non-Insulated NEMA W W T T E E B B FITS L L Hand L L Hand zy zy * Special Order NEMA W W T T E E B B FITS FIT L L Hand Funnel L L Hand zy * Special Order zy ** Locator Blade 13-023 to be ordered in addition to Hand Tool. 16/14 Male Slip-Ons Barrel Inside Diameter Material: BRASS Thickness: .020" / .508 mm .032” / .813 mm Basic Dimensions Non-Insulated NEMA C C E E B B FITS L L Hand L L Hand zy zy * Special Order Basic Dimensions Insulated (Blue Vinyl) Insulated (Blue Nylon) NEMA C C E E B B FITS Funnel Insul. Dia. L L Hand Funnel Insul. Dia. L L Hand zy zy * Special Order Most terminals available tape mounted. Consult Electro
12/10 Female Slip-Ons CMA Range 5180-13,100 Barrel Inside Diameter .129"/ 3.27 mm Material: BRASS Thickness: .018" / .457 mm Basic Dimensions Non-Insulated NEMA W W T T E E L L Hand Tool E E L L zy * UL Listed for 12 AWG only
- Not UL listed † True Barrel – 1 pc part SO9300 = SO9076 & 1049 sleeve y Insulated (Yellow Vinyl) Insulated (Yellow Nylon) Basic Dimensions NEMA W W T T Funnel E E L L Hand Funnel E E L L Hand Tool H6E zy UL Listed for 12 AWG Only zy UL Listed for 12 AWG Only † 4 pc part 22/18 • 16/14 • 12/10 Piggy Back Slip-Ons Material: BRASS Thickness: .016" / .406 mm Basic Dimensions Non-Insulated Insul. I.D. CMA Wire NEMA L Hand H270 L Hand H270 Color In./mm. Range Range Tab NIT In. Tool Die NIT-IG In. Tool Die zy * UL Listed for 12 AWG Only zy * UL Listed for 12 AWG Only Basic Dimensions Insulated (Vinyl) Insulated (Nylon) Color In./mm. Range Range Tab FIT Dia. L Tool NIT-IG Dia. L Tool zy * UL Listed for 12 AWG Only zy * UL Listed for 12 AWG Only www.hollingsworth.com 800.638.8376 Most terminals available tape mounted. Consult Electro-Term/Hollingsworth with your specifications.
22/18 • 16/14 • 12/10 Flag Slip-Ons Material: BRASS Thickness: .018" / .457mm Basic Dimensions Non-Insulated Wire CMA NEMA W W T T E E L L E E L L Hand Tool H4A3 H12 zy * UL Listed for 12 AWG Only zy Notched specially for Bending applications 22/18 • 16/14 • 12/10 Flag Slip-Ons Material: BRASS Thickness: .018" / .457mm Basic Dimensions Non-Insulated Wire CMA NEMA W W T T E E L L E E L L zy * UL Listed for 12 AWG Only zy * UL Listed for 12 AWG Only Basic Dimensions Fully-Insulated Wire CMA NEMA W W T T FISO Insul Dia. L L Ins. Bbl. Dia Insul. Hand zy 22/16 • 16/14 • 12/10 Knife Disconnects Material: COPPER Basic Dimensions Non-Insulated Wire CMA Mat. Thickness Ins. Bbl. Dia. H H W W B B L L L L H270 Hand Tool H4A See End Column Basic Dimensions Insulated (Nylon) Most terminals available tape mounted. Consult Electro
22/18 Male Plugs CMA Range 509-2050 Barrel Inside Diameter .057/ 1.49 mm Material: BRASS Thickness: .018" / .457 mm Insulated (Red Nylon) Basic Dimensions Insul. Dia. .118" / 3.00 mm W W E E Funnel L L In. mm In. mm FIIG In. mm Hand Tool H43 y 22/18 Receptacles CMA Range 509-2050 Barrel Inside Diameter .057/ 155 mm Material: BRASS Thickness: .016" / .406 mm Insulated (Red Vinyl) Basic Dimensions Insul. Dia. .125" / 3.18 mm W W E E Male Plug Male Plug Fully Insulated L L H270 Die 27123 Hand Tool H35 y 18/14 Male Plugs CMA Range 1600-5180 Barrel Inside Diameter .081/ 2.06 mm Material: BRASS Thickness: .018" / .457 mm Insulated (Blue Nylon) Basic Dimensions Insul. Dia. .146" / 3.71 mm W W E E Funnel L L In. mm In. mm FIIG In. mm Hand Tool H43 y 18/14 Receptacles CMA Range 1600-5180 Barrel Inside Diameter .081/ 2.06 mm Material: BRASS Thickness: .016" / .406 mm Insulated (Blue Vinyl) Basic Dimensions Insul. Dia. .160" / 4.06 mm W W E E Male Plug Male Plug Fully Insulated L L H270 Die 27121 Hand Tool H35 y 16/14 Male Plugs CMA Range2050-5180 Barrel Inside Diameter ..081/ 2.06 mm Material: COPPER Thickness: .032" / .813 mm Insulated (Blue Vinyl) Insulated (Blue Nylon) W W L L Funnel L L Funnel L L In. mm NIT In. mm FIT In. mm FIIG In. mm Hand Tool H4A H7B & H53 H7B & H53 www.hollingsworth.com 800.638.8376 Most terminals available tape mounted. Consult Electro-Term/Hollingsworth with your specifications.
High Temperature - 650°F / 900° F / 1200°F Terminals and Connectors, Wire Sizes 22 to 2 AWG For high temperature applications: maximum operating temperatures are 650°F, 900°F, or 1200°F. 650°F (343°C) 650°F terminals are made of Nickel-plated pure copper. NIT Brazed Insulation Grip Basic Dimensions Non-Insulated Insulation Grip Wire Size Stud Size Max. Width W (In.) Min. Clearance C (In.) NIT Brazed Max Length L (In.) Hand Tool NIT-IG Max Length L (In.) H270 Die 22-16 10* .31 .32 R4278SB .65 H4A R4278SBMG .84 27089 16-14 10* .31 .28 R4308SB .62 H4A R4308SBMG .83 27092 12-10 10* .37 .28 R3430B .74 H4A R3430BMG .95 27095 8 10* .38 .39 R3472B .90 H20 6 1/4 .47 .54 R64663B 1.18 H20 6 5/16 .63 .54 R64661B 1.26 H20 6 3/8 .63 .54 R64662B 1.26 H20 4 1/4 .56 .50 R5023B 1.25 H20 4 5/16 .66 .50 R5018B 1.30 H20 4 3/8 .66 .50 R5019B 1.30 H20 2 1/4 .70 .60 R8027B 1.50 H20 2 5/16 .70 .60 R8028B 1.50 H20 Operating conditions in this maximum temperature range calls for 650°F (343°C) terminals and splices. Both terminals and splices are constructed of nickel-plated copper. The terminals are available in two barrel styles: the Brazed Barrel seam and the Insulation Grip, which includes a wire insulation support sleeve made of copper with a bright nickel plating. 2 3/8 .70 .60 R8029B 1.50 H20 900°F (483°C) 900°F terminals are made of a Nickel-Plated Steel Alloy. NIT Basic Dimensions Non-Insulated Wire Size Stud Size Max. Width W (In.) Min. Clearance C (In.) NIT Max Length L (In.) Hand Tool 22-16 10* .31 .32 R4273S ● .65 H16HT 16-14 10* .31 .28 R4303S ● .62 H16HT 12-10 10* .37 .28 R3423 ● .74 H16HT 8 10* .38 .39 R3557 .90 H20 6 1/4 .47 .54 R64682 1.18 H20 6 1/4 .63 .54 R64681 1.26 H20 6 5/16 .63 .54 R64680 1.26 H20 6 3/8 .63 .54 R64683 1.26 H20 4 1/4 .56 .50 R5216 1.25 H20 4 5/16 .66 .50 R5217 1.30 H20 4 3/8 .66 .50 R5218 1.30 H20 2 1/4 .70 .60 R8039 1.50 H20 2 5/16 .70 .60 R8040 1.50 H20 Hollingsworth also offers a line of terminals designed to perform satisfactorily in ambient operating temperature ranges to 900°F (483°C). These nickel-plated, steel alloy products are available in the butted seam, barrel style. Ring tongue terminals cover the 22 through 2 AWG wire ranges to provide reliable performance time after time even in these hostile temperature environments. 2 3/8 .70 .60 R8041 1.50 H20 1200°F (649°C) 1200°F Terminals are pure Nickel. NIT NIT Brazed Basic Dimensions Non-Insulated Wire Size Stud Size Max. Width W (In.) Min. Clearance C (In.) NIT Max Length L (In.) Hand Tool NIT Brazed Max Length L (In.) Hand Tool 22-16 10* .31 .32 R4530S .65 H16HT R4530SB .65 H16HT 16-14 10* .31 .28 R4537S .62 H16HT R4537SB .62 H16HT 12-10 10* .37 .28 R3535 .74 H16HT R3535B .74 H16HT 8 10* .38 .39 R3563 .90 H20 R3563B .90 H20 6 1/4 .47 .54 R64684 1.18 H20 R64684B 1.18 H20 6 5/16 .63 .54 R64685 1.26 H20 R64685B 1.26 H20 6 3/8 .63 .54 R64686 1.26 H20 R64686B 1.26 H20 4 1/4 .56 .50 R5219 1.25 H20 R5219B 1.25 H20 4 5/16 .66 .50 R5220 1.30 H20 R5220B 1.30 H20 4 3/8 .66 .50 R5221 1.30 H20 R5221B 1.30 H20 2 1/4 .70 .60 R8042 1.50 H20 R8042B 1.50 H20 2 5/16 .70 .60 R8043 1.50 H20 R8043B 1.50 H20 The ultimate in thermal reliability is afforded by the 1200°F (649°C). The ring tongue terminals, which are fabricated from pure nickel, cover the 22 through 2 AWG wire range. The terminals have either the butted seam barrel or the brazed barrel style. 3/8 .70 .60 R8044 1.50 H20 R8044B 1.50 H20 Most terminals available tape mounted. Consult Electro-Term/Hollingsworth with your specifications. 800.638.8376 www.hollingsworth.com y
- CSA Listed
16/14 Male Slip-Ons 650°F CMA Range 2050-5180 Barrel Inside Diameter .085/ 2.16 mm Material: NICKEL PLATED BRASS Thickness: .032" / .813 mm Basic Dimensions Non-Insulated NEMA C C NIT E E L L TAB In. mm Brazed In. mm In. mm Hand Tool H4A zy 18/14 Male Slip-Ons 900°F Also available in 1200°F Nickel CMA Range 1600-5180 Barrel Inside Diameter .085/ 2.16 mm Material: NICKEL PLATED STEEL ALLOY Thickness: .032" / .813 mm Basic Dimensions Non-Insulated NEMA C C E E L L TAB In. mm NIT In. mm In. mm Hand Tool H16HT y 22/10 Butt connectors 650°F - 900°F Material: NICKEL PLATED COPPER Material: NICKEL PLATED STEEL ALLOY Basic Dimensions Non-Insulated 650°F 900 °F Size CMA Range Brazed In. mm In. mm In. mm Hand Tool H4A H16HT y Female Slip-Ons 900°F 18/14 CMA Range 1600-5180 Barrel Inside Diameter .081/ 2.06 mm CMA Range 5100-13,100 Barrel Inside Diameter .130/ 3.30 mm Material: NICKEL PLATED STEEL ALLOY Thickness: .018" / .457 mm Basic Dimensions Non-Insulated NEMA W W T T E E L L HAND TAB In. mm In. mm NIT In. mm In. mm TOOL * 12/10 AWG y www.hollingsworth.com 800.638.8376 Most terminals available tape mounted. Consult Electro-Term/Hollingsworth with your specifications.
Terminals / Splices for Wire Sizes 8 AWG to 250 MCM All terminals in this section are made from pure copper for highest conductivity. They are electro-tin plated to assure corrosion resistance. Serrated “V” grooves in the barrel of each terminal firmly grip the wire to assure maximum holding power. Insulation is colored to standard commercial specifications. NIT BRAZED Non-Insulated Terminal FIT Fixed Insulated Terminal Consists of a bare terminal with a smooth, silver-alloy brazed barrel
- Chamfered end of barrel affords fast and easy insertion of wire
- Brazed barrel can be crimped anywhere (even on seam) without splitting
- Some butt connectors and parallel splices are made from seamless tubular stock and offer the same advantages as brazed barrel parts. These parts are indicated by an An assembly of a bare terminal with tightly fitting insulating sleeve made of PVC or nylon
- Offers excellent insulating qualities.
- Resists minor vibrations
- Insulation color-coded to standard commercial specifications FIT FLARED Fixed Insulated Terminal Flared Insulation FUNNEL FIT Fixed Insulated Terminal Funnel Entry An assembly of a bare terminal with a tightly fitted flared insulating sleeve made of PVC
- Flared insulation will accept heavily insulated wire
- Offers excellent insulating qualities
- Resists minor vibrations
- Insulation color-coded to standard commercial specifications An assembly of a brazed terminal with a tightly fitted nylon insulating sleeve
- Funnel entry barrel facilitates wire entry
- Offers excellent insulating qualities
- Prevents insulation unraveling
- Resists minor vibrations
- Insulation color-coded to standard commercial specifications 8 – 3/0 AWG Parallels Material: SEAMLESS COPPER TUBULAR STOCK Basic Dimensions Non-Insulated Insulated (Vinyl) Hand Tool See Above H20 H20 8 – 1/0 AWG Butt Connectors Material: COPPER Basic Dimensions Non-Insulated Insulated (Vinyl) Insulated (Nylon) 8 13,100- 6 20,800- 4 33,100- 2 52,600- 1/0 83,700- Hand Tool See Above H20 H20 ‡ Made from seamless tubular stock N* Items on this page are also available in nylon. To order, add N suffix to catalog number. Example: BO110BN Most terminals available tape mounted. Consult Electro
8 Rings CMA Range 13,100-20,800 Barrel Inside Diameter .173"/ 4.39 mm Material: COPPER Thickness: .045" / 1.14 mm Insulated (Red Vinyl) Insulated (Red Nylon) Insulation Diameter Insulation Diameter Basic Dimensions Non-Insulated Stud W W C C NIT E E L L E E L L FIT Funnel E E L L Hand Tool H20 H20 H20 H20 zy zy N* zy zy N* Items on this page are also available in nylon. To order, add N suffix to catalog number. Example: BO110BN 6 Rings CMA Range 20,800-33,100 Barrel Inside Diameter .238"/ 6.05 mm Material: COPPER Thickness: .057" / 1.45 mm Insulated (Blue Vinyl) Insulated (Blue Nylon) Insulation Diameter Insulation Diameter Basic Dimensions Non-Insulated Stud W W C C NIT E E L L E E L L FIT Funnel E E L L Hand Tool H20 H20 H20 H20 zy zy N* zy zy N* Items on this page are also available in nylon. To order, add N suffix to catalog number. Example: R400BN www.hollingsworth.com 800.638.8376 Most terminals available tape mounted. Consult Electro-Term/Hollingsworth with your specifications.
4 Rings CMA Range 33,100-52,600 Barrel Inside Diameter .287"/ 7.29 mm Material: COPPER Thickness: .068" /1.73 mm Insulated (Yellow Vinyl) Insulated (Yellow Nylon) Insulation Diameter Insulation Diameter Basic Dimensions Non-Insulated Stud W W C C NIT E E L L E E L L FIT Funnel E E L L Hand Tool H20 H20 H20 H20 zy zy N* zy zy 2 Rings CMA Range 52,600-83,700 Barrel Inside Diameter .355"/9.02 mm Material: COPPER Thickness: .078" / 1.98 mm Insulated (Red Vinyl) Insulated (Red Nylon) Insulation Diameter Insulation Diameter Basic Dimensions Non-Insulated Stud W W C C NIT E E L L E E L L FIT Funnel E E L L Hand Tool H20 H20 H20 H20
1 Rings – Special Order
CMA Range 83,100-105,600 Material: COPPER Thickness: .060" / 1.52 mm Insulated (White Nylon) Basic Dimensions Non-Insulated Insul. Dia. .590" / 14.99 mm Stud W W R R NIT E E L L Funnel E E L L N* Items on this page are also available in nylon. To order, add N suffix to catalog number. Example: R7998BN Hand Tool H30/H40 H30/H40 Most terminals available tape mounted. Consult Electro
1/0 Rings CMA Range 83,700-119,500 Barrel Inside Diameter .443" / 11.25 mm Max Wire Diameter .435” / 11.05 mm Material: COPPER Thickness: .075" / 1.90 mm Insulated (Blue Nylon) Basic Dimensions Non-Insulated Insul. Dia. .695" / 17.65 mm Stud W W R R NIT E E L L Funnel E E L L Hand Tool H30/H40 H30/H40 2/0 Rings CMA Range 119,500-150,500 Barrel Inside Diameter .502" / 12.75 mm Max Wire Diameter .490” / 12.45 mm Material: COPPER Thickness: .083" / 2.10 mm Insulated (Yellow Nylon) Basic Dimensions Non-Insulated Insul. Dia. .785" / 19.93 mm Stud W W R R NIT E E L L Funnel E E L L Hand Tool H30/H40 H30/H40 3/0 Rings CMA Range 150,500-190,900 Barrel Inside Diameter .572" / 14.53 mm Max Wire Diameter .560” / 14.22 mm Material: COPPER Thickness: .093" / 2.36 mm Insulated (Red Nylon) Basic Dimensions Non-Insulated Insul. Dia. .810" / 20.57 mm Stud W W R R NIT E E L L Funnel E E L L Hand Tool H40 H40 4/0 Rings CMA Range 190,000-231,000 Barrel Inside Diameter .641" / 16.28 mm Max Wire Diameter .635” / 16.01 mm Material: COPPER Thickness: .105" / 24.39 mm Insulated (Blue Nylon) Basic Dimensions Non-Insulated Insul. Dia. .960" / 24.38 mm Stud W W R R NIT E E L L Funnel E E L L Hand Tool H40 H40 www.hollingsworth.com 800.638.8376 Most terminals available tape mounted. Consult Electro-Term/Hollingsworth with your specifications.
.032 x .250 Male Tabs Material: TIN PLATED BRASS Thickness: .032" / .813 mm Stud Angle Size "Z" Type Tab NIT 6 0 Straight H106 † 6 30 Bent H130 6 45 Bent H132 6 60 Bent H134 6 90 Right Angle H116 8 0 Straight H108 † 8 30 Bent H131 8 45 Bent H133 8 60 Bent H135 8 90 Right Angle H118 y Fuse Adaptors & Tap Male Fuse Clip Adaptor AGC Fuse Adapt or ATO Fuse Adaptor Mini Fuse Tap A47 A50-AGC A50-ATO A50-MIN .032 x .250 Male Tab pairs STYLE K STYLE L STYLE M Material Thickness: .032" / .813 mm “W” Dimension: 250" / .6.35mm Hole Dia. L L Hole Dia. L L NIT Pairs Style In. mm Material In. mm NIT Pairs Style In. mm Material In. mm H2634 4 L .130 3.30 Tin Plated Brass 1.440 36.58 y y Most terminals available tape mounted. Consult Electro † The H106 and H108 Straight tabs are used to create the bent tab parts immediately following, i.e., H106 bent 30° = H130.
22/10 Wire Pins CMA Range 509-3260 Barrel Inside Diameter .061/ 1.55 mm Insulated (Red Vinyl) Insulated (Red Nylon) W H X NIT L Funnel L Funnel L Hand Tool H4A H4A H7B & H53 H7B & H53 Insulated (Blue Vinyl) Insulated (Blue Nylon) W H X NIT L Funnel L Funnel L Hand Tool H4A H4A H7B & H53 H7B & H53 Insulated (Yellow Vinyl) Insulated (Yellow Nylon) W H X NIT L Funnel L Funnel L Hand Tool H4A H4A H6E & H53 H6E & H53 y y y y 12/2 Flag Rings Material: COPPER Basic Dimensions Non-Insulated Wire CMA Stud Barrel I.D. W W C C Mat'l. Thk. NIT E E L L www.hollingsworth.com 800.638.8376 Most terminals available tape mounted. Consult Electro-Term/Hollingsworth with your specifications.
AS7928 is the most commonly used government specification for Solderless terminals. This specification permits the use of Class 1 and Class 2 terminals.
- Type I Class 1 terminals are those uninsulated terminals which, when crimped with an MS approved crimping tool, meet all dimensional and performance requirements of the specification.
- Type II Class 1 terminals are those insulated terminals which, when crimped with an MS approved tool, meet the dimensional and performance requirements of the specification.
- Both Type I Class 2 and Type II Class 2 terminals are those which, when crimped with tooling recommended by the manufacturer, meet the performance requirements of the specifications. The Hollingsworth terminals which are on the QPL can be found below. MIL SPEC AS25036 (Insulated) Item W W C C E E L L Type II Class 1 Hand Type II Class 2 Hand Wire Stud MIL SPEC AS20659 (Non-Insulated) Item W W C C E E L L Type I Type I Wire Stud Number In. mm In. mm In. mm In. mm Class 1 Class 2 Size Size MIL SPEC AS7928/7 (Non-Insulated) Ring Tongue Item W W C C E E L L Type I Type I Wire Stud Number In. mm In. mm In. mm In. mm Class 1 Class 2 Size Size Most terminals available tape mounted. Consult Electro-Term/Hollingsworth with your specifications. 800.638.8376 www.hollingsworth.com
Miscellaneous Data and Information WIRE GAGE CONVERSION CHART AWG CMA MM2 26 - 24 202 - 320 0.10 - 0.16 26 - 22 202 - 810 0.10 - 0.41 24 - 20 320 - 1290 0.16 - 0.65 22 - 18 509 - 2050 0.30 - 1.04 22 - 16 509 - 3260 0.30 - 1.65 20 - 16 1290 - 3260 0.65 - 1.65 18 - 14 1600 - 5180 0.81 - 2.62 16 - 14 2050 - 5180 1.04 - 2.62 14 - 12 3260 - 8230 1.65 - 4.17 12 - 10 5180 - 13,100 2.62 - 6.64 8 13,100 - 20,800 6.64 - 10.54 6 20,800 - 33,100 10.54 - 16.77 4 33,100 - 52,600 16.77 - 26.65 2 52,600 - 83,700 26.65 - 42.41 1/0 83,700 - 119,500 42.41 - 60.55 2/0 119,500 - 150,500 60.55 - 76.26 3/0 150,500 - 190,000 76.26 - 96.27 4/0 190,000 - 231,000 96.27 - 117.05
250 MCM 250,000 127
300 MCM 300,000 152
350 MCM 350,000 177
400 MCM 400,000 203
500 MCM 500,000 253
1/64 0.015625 33/64 0.515625 1/32 0.03125 17/32 0.53125 3/64 0.046875 35/64 0.546875 1/16 0.0625 9/16 0.5625 5/64 0.078125 37/64 0.578125 3/32 0.09375 19/32 0.59375 7/64 0.109375 39/64 0.609375 1/8 0.125 5/8 0.625 9/64 0.140625 41/64 0.640625 5/32 0.15625 21/32 0.65625 11/64 0.171875 43/64 0.671875 3/16 0.1875 11/16 0.6875 13/64 0.203125 45/64 0.703125 7/32 0.21875 23/32 0.71875 15/64 0.234375 47/64 0.734375 1/4 0.25 3/4 0.75 17/64 0.265625 49/64 0.765625 9/32 0.28125 25/32 0.78125 19/64 0.296875 51/64 0.796875 5/16 0.3125 13/16 0.8125 21/64 0.328125 53/64 0.828125 11/32 0.34375 27/32 0.84375 23/64 0.359375 55/64 0.859375 3/8 0.375 7/8 0.875 25/64 0.390625 57/64 0.890625 13/32 0.40625 29/32 0.90625 27/64 0.421875 59/64 0.921875 7/16 0.4375 15/16 0.9375 29/64 0.453125 61/64 0.953125 15/32 0.46875 31/32 0.96875 31/64 0.484375 63/64 0.984375 1/2 0.5 1 1.0 STUD SIZE CHART Diameter Inches mm 0 cm 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 in 1 2 3 4 5 6 www.hollingsworth.com 800.638.8376
Performance Characteristics These tests were performed under strict laboratory controlled conditions and may vary depending on type of wire and terminal combinations, wire stripping methods, and maintenance or proper gauging and calibration of manufacturer’s recommended tooling. CHART 9072 Corrosion (Salt Spray) Test 48 hours, 5% NACL Fog Note: Specification Maximum: Voltage drop of equivalent wire length, plus specification allowance. Salt Spray (Corrosion Test)
- The purpose of this test, in which terminal samples are subjected to a file mist of 5% salt solution for a specific time (48 hours), is to provide an accelerated laboratory conducted corrosion test.
- The curves shown on chart 9072 plot the final voltage drops (i.e., after subjecting the samples to salt spray), as called for in specification AS7928. For a terminal to meet or exceed requirements, its voltage drop readings after test must fall below limits shown in the upper curve (final). All Hollingsworth Military approved terminals exceed AS7928 Salt Spray (Corrosion) Test requirements. CHART 9073 Vibration Test 10-55 C.P.S. 36 hours Note: Specification Maximum: Voltage drop of equivalent wire length, plus specification allowance. Vibration Test
- The purpose of this test is to determine the detrimental effect of vibration on the terminal. Terminals are attached to each end of a suitable length of wire. The test terminals are mounted in a specially built vibration machine, confirming to the requirements as set out in paragraph 4.7.7 of specifications AS7928.
- The test terminals are subjected to vibrations of 10 through 55 cps. for a period of 18 hours in one plane and a further 18 hours in a plane normal to the first; a total test period of 36 hours aand are subjected to voltage drop tests before and after vibration.
- The curves shown on chart 9073 plot voltage drops (i.e., after subjecting the samples to the vibration test). For a terminal to meet or exceed requirements, its voltage drop readings after test must fall below the limits shown in the upper curve 9final). All Hollingsworth Military approved terminals exceed AS7928 Vibrations Tests. Tensile Strength Test
- The purpose of this test is to ensure secureness of the crimped terminal. The test is carried out as indicated under paragraph 4.7.8 of specifications AS7928.
- After crimping the terminal to a suitable length of wire, it is placed in a standard tensile testing machine and sufficient force is applied to pull the wire out of the terminal or break the wire, or the terminal.
- The lower curve on charts 9074 and 9075 plots the minimum pull out force expected for the various wire sizes crimped. The upper curve plots average pull out forces measured in actual tests on numerous samples. All Hollingsworth Military approved terminals exceed AS7928 Tensile Strength requirements. CHART 9074 Tensile Strength Test 26-10 AWG CHART 9075 Tensile Strength Test 8-4/0 AWG AN WIRE SIZE SPECIFICATION AS7928F MAX HOLLINGSWORTH TERMINAL MAXIMUM – AFTER CORROSION MILL/VOLTS AN WIRE SIZE SPECIFICATION AS7928F MAX HOLLINGSWORTH TERMINAL MAXIMUM – AFTER VIBRATION MILL/VOLTS