Technical content

MODEL: R3-YV4 R3-YV4 SPECIFICATIONS ES-8372 Rev.13 Page 1/3 https://www.m-system.co.jp/ Remote I/O R3 Series DC VOLTAGE OUTPUT MODULE (4 points, isolated) 109 [4.29] 27 .5 [1 .08] 130 [5.12] mm [inch] MODEL: R3-YV4[1][2]

ORDERING INFORMATION

  • Code number: R3-YV4[1][2] Specify a code from below for each of [1] and [2]. (e.g. R3-YV4W/CE/Q)
  • Specify the specification for option code /Q (e.g. /C01/SET) NO. OF CHANNELS 4: 4 [1] COMMUNICATION MODE S: Single W: Dual [2] OPTIONS (multiple selections) Standards & Approvals blank: Without CE /CE: CE marking Other Options blank: none /Q: Option other than the above (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-8372) GENERAL SPECIFICATIONS Connection Internal bus: Via the Installation Base (model: R3-BSx) Output: M3 separable screw terminal (torque 0.5 N·m) Internal power: Via the Installation Base (model: R3-BSx) Screw terminal: Nickel-plated steel Isolation: Output 1 to output 2 to output 3 to output 4 to internal bus or internal power Output range: Selectable with the side DIP SW Output hold function: Setting for communication error with side DIP SW RUN indicator: Bi-color (red/green) LED; Red when the bus A operates normally; Green when the bus B operates normally; Amber when both buses operate normally. ERR indicator: Green LED turns on in normal operating conditions. OUTPUT SPECIFICATIONS ■ Narrow Span: -1 – +1 V, 0 – 1 V DC Load resistance: 10 kΩ min. ■ Wide Span: -10 – +10 V, -5 – +5 V, 0 – 10 V, 0 – 5 V, 1 – 5 V DC Load resistance: 10 kΩ min. ■ Output Range Except -10 to +10 V DC: -15 to +115 % of output range -10 to +10 V DC: Approx. -11.5 to +11.5 V DC INSTALLATION Operating temperature: -10 to +55°C (14 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: Installation Base (model: R3-BSx) Weight: 200 g (0.44 lb) PERFORMANCE Conversion accuracy (Range): 0 – 10 V : ±0.05 % 0 – 5 V : ±0.1 % 1 – 5 V : ±0.1 % 0 – 1 V : ±0.1 % Data range: 0 – 10000 of the output range Data allocation: 4 Current consumption: 150 mA Temp. coefficient: ±0.015 % /°C (±0.008 %/°F) (±0.03 % /°C [±0.02 %/°F] with 0 – 5 V or 1 – 5 V range) Response time: ≤ 0.2 sec. (0 – 90 %)

MODEL: R3-YV4 R3-YV4 SPECIFICATIONS ES-8372 Rev.13 Page 2/3 https://www.m-system.co.jp/ Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 1500 V AC @ 1 minute (output 1 to output 2 to output 3 to output 4 to internal bus or internal power)

2000 V AC @ 1 minute (power input to FG; isolated on the

power supply module) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 RoHS Directive FUNCTIONS ■OUTPUT HOLD or OUTPUT OFF In normal conditions, the module outputs the signal from the preferred bus A. When an error is detected, the output is switched to the data from the bus B.

  • Output Hold If both are in error, the module holds the signal and stands by until one of the communications recovers.
  • Output OFF If both are in error, the module outputs -15 % (or approx. -11.5 V) and stands by until one of the communications recovers. At the startup, it outputs -15 % (or approx. -11.5 V) until the communication is established and normal data is received. EXTERNAL VIEW 111 ON SW1SW2 ON SW3 ON ■ FRONT VIEW ■ SIDE VIEW ERR LED RUN LED Output Hold Output 2 (SW1) or Output 4 (SW2) Range Output 1 (SW1) or Output 3 (SW2) Functions

MODEL: R3-YV4 R3-YV4 SPECIFICATIONS ES-8372 Rev.13 Page 3/3 https://www.m-system.co.jp/ EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch] 111 130 [5.12] POSITIONING GUIDE TERMINAL COVER 20–M3 SCREW 6.2 [.24] SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Communication Circuit INTERNAL POWER INTERNAL BUS A INTERNAL BUS B 11 + Output Circuit Control Circuit BUS CONNECTOR DIP SWRUN LED ERR LED OUTPUT 1 NARROW SPAN WIDE SPAN 13 + Output Circuit OUTPUT 2 NARROW SPAN WIDE SPAN 16 + Output Circuit OUTPUT 3 NARROW SPAN WIDE SPAN 18 + Output Circuit OUTPUT 4 NARROW SPAN WIDE SPAN Note: Connect either wide or narrow span terminals for each channel. * For dual redundant communication. Specifications are subject to change without notice.