www.relpol.com.pl 14.07.2014 Export Sales Department phone +48 68 47 90 832, 951 • e-mail: export@relpol.com.pl R3N miniature industrial relays 3 CO AgNi, AgNi/Au 0,2 µm
250 V / 440 V
10 A / 250 V AC
3 A / 120 V 1,5 A / 240 V (B300)
370 W (single-phase motor)
10 A / 24 V DC (see Fig. 3) 0,22 A / 120 V 0,1 A / 250 V (R300) 5 mA 20 A 10 A 2 500 VA 0,3 W 100 m 1 200 cycles/hour 18 000 cycles/hour 6 ... 240 V 5 ... 220 V AC: 0,2 Un DC: 0,1 Un see Tables 1, 2 1,6 VA 0,9 W
250 V AC
1,2 / 50 µs III 2 500 V AC type of insulation: basic 1 500 V AC type of clearance: micro-disconnection 2 500 V AC type of insulation: basic 2,5 mm 4 mm AC: 10 ms / 8 ms DC: 13 ms / 3 ms > 105 10 A, 250 V AC see Fig. 2 > 2 x 10 27,5 x 21,2 x 35,6 mm 35 g -40...+85 oC IP 40 PN-EN 60529 RTI PN-EN 116000-3 10 g / 5 g 5 g 10...150 Hz Contact data Number and type of contacts Contact material Rated / max. switching voltage AC Min. switching voltage Rated load (capacity) AC1 AC15 AC3 DC1 DC13 Min. switching current Max. inrush current Rated current Max. breaking capacity AC1 Min. breaking capacity Contact resistance Max. operating frequency
- at rated load AC1
- no load Coil data Rated voltage 50/60 Hz AC DC Must release voltage Operating range of supply voltage Rated power consumption AC DC Insulation according to PN-EN 60664-1 Insulation rated voltage Rated surge voltage Overvoltage category Insulation pollution degree Dielectric strength
- between coil and contacts
- contact clearance
- pole - pole Contact - coil distance
- clearance
- creepage General data Operating / release time (typical values) Electrical life
- resistive AC1
- cos Mechanical life (cycles) Dimensions (L x W x H) Weight Ambient temperature • storage
- operating Cover protection category Environmental protection Shock resistance (NO/NC) Vibration resistance The data in bold type pertain to the standard versions of the relays.
- Relays of general application • For plug-in sockets: 35 mm rail mount acc. to PN-EN 60715; on panel mounting • Miniature dimensions • Cadmium - free contacts • AC and DC coils
- WT (mechanical indicator + lockable front test button) - standard features of relays. Relays may be provided with the test buttons (no latching) and plugs - page 10
- Recognitions, certifi cations, directives: RoHS,
www.relpol.com.pl 14.07.2014 Export Sales Department phone +48 68 47 90 832, 951 • e-mail: export@relpol.com.pl R3N miniature industrial relays The data in bold type pertain to the standard versions of the relays. The data in bold type pertain to the standard versions of the relays. Coil data - DC voltage version Table 1 Coil operating range V DC min. (at 20 °C) max. (at 55 °C) Acceptable resistance Rated voltage V DC Coil resistance at 20 °C Coil code Coil data - AC 50/60 Hz voltage version Table 2 Coil operating range V AC min. (at 20 °C) max. (at 55 °C) Acceptable resistance Rated voltage V AC Coil resistance at 20 °C Coil code 4,8 9,6 19,2 33,6 38,4 48,0 64,0 88,0 92,0 96,0 101,6 176,0 184,0 192,0 6,6 13,2 26,4 46,2 52,8 66,0 88,0 121,0 127,0 132,0 139,0 242,0 253,0 264,0 ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% 4,0 4,8 9,6 19,2 38,4 48,0 64,0 88,0 100,0 176,0 5,5 6,6 13,2 26,4 52,8 66,0 88,0 121,0 137,5 242,0 ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% 5006 5012 5024 5042 5048 5060 5080 5110 5115 5120 5127 5220 5230 5240 110 115 120 127 220 230 240 9,8 39,5 158 470 640 930 1 720 3 450 3 610 3 770 4 000 15 400 16 100 16 800 1005 1006 1012 1024 1048 1060 1080 1110 1125 1220 110 125 220 160 640 2 600 4 000 7 100 13 600 16 000 54 000 NEW TECHNOLOGY The new R2N, R3N, R4N relays are modernized versions of the R2, R3, R4 relays. The modernization covered the design of the relays and the manufacturing process.
www.relpol.com.pl 14.07.2014 Export Sales Department phone +48 68 47 90 832, 951 • e-mail: export@relpol.com.pl R3N miniature industrial relays Design Improvement of the functio nality of the mechanical indicator (W): it is mounted on an insulation base of the unit of the movable contacts; the changes provide the appropriate position in the window in the upper side of the housing irrespectively of the number of operations performed by the relay. Improvement of the effi ciency of the electromagnet: an innovational technology of connecting elements has been introduced, which guarantees more reliable opera- tion of the relay. Strengthening of the insulation in the area of the contact plate: polyamide PA66 has been applied; it has very good mechanical and electrical parameters and best thermal properties. Application of electronics made in the SMD techno- logy: additional features L (LED diode) and D (diode) are located on the printed circuit board; the change of the position of the LED diode and optimization of the quality and intensity of its light provide certainty that the relay is in operation status when the LED is on. 3 CO Note: the indicated polarity of the supply refers to the relays with extra equipment D - surge suppression element (diode) - for DC coils only. Test buttons R4P-0001 and plugs R4W-0003 need to ordered saparately. They substitute buttons type T. To exchange by Customer themselves. Information on test buttons (no latching) and plugs - page 10. Dimensions - plug-in version (WT), with lockable front test button type T Dimensions - plug-in version, with test button (no latching) or with plug (no manual operation) Connection diagram (pin side view)
www.relpol.com.pl 14.07.2014 Export Sales Department phone +48 68 47 90 832, 951 • e-mail: export@relpol.com.pl R3N miniature industrial relays Electrical life at AC resistive load. Fig. 1 Switching frequency: 1 200 cycles/hour Electrical life reduction factor Fig. 2 at AC inductive load Breaking capacity [kVA] Number of cycles N DC current [A] DC voltage [V] Max. DC breaking capacity A - resistive load DC1 Fig. 3 B - inductive load L/R = 40 ms Relays R3N are offered in versions for plug-in sockets, with WT features as standard ( W - mechanical indi- cator + T - lockable front test button). In these relays is possibility self-exchange of button type T for test button R4P-0001 (no latching) or on plug R4W-0003 (no manual operation). The buttons R4P-0001 and the plugs R4W-0003 need to ordered saparately. Relays R3N are designed for: • screw terminals plug- -in sockets GZT3 ❶ and GZM3 ❶ with clip GZT4-0040 or G4 1052 , 35 mm rail mount acc. to PN-EN 60715 or on panel mounting with two M3 screws. Signalling / protecting modules type M... are available with sockets (see page 7). ❶ Plug-in sockets GZT3, GZM3 may be linked with inter con nection strip type ZGGZ4 (see page 8). Mounting Reduction factor Power factor N - electrical life at AC1
- AgNi - for resistive or inductive loads,
- AgNi/Au 0,2 µm - Au protects the contact surface during storage. Contact material selection for different load types
www.relpol.com.pl 14.07.2014 Export Sales Department phone +48 68 47 90 832, 951 • e-mail: export@relpol.com.pl R3N miniature industrial relays — — —3 N — see Tables 1, 2 page 2 Ordering codes Type Contact material Number and type of contacts Cover protection category Connection mode Coil code Number and type of contacts 13 - 3 CO Note: For relays with additional features D - surge suppression element (diode) (versions WTD and WTLD) - fixed supply polarity compulsory for the DC load of coils: +A1(13) / -A2(14). The polarity is indicated on the relay cover. For other versions of the relays with DC coils any polarity is possible. Example of ordering code: R3N-2013-23-1024-WT relay R3N, for plug-in sockets, three changeover contacts, contact material AgNi, coil voltage 24 V DC, with mechanical indicator and lockable front test button, in cover IP 40 Contact material 20 - AgNi 21 - AgNi/Au 0,2 µm Connection mode 3 - for plug-in sockets Cover protection category 2 - in cover, IP 40 version Additional
features
without marks - without additional features WT - mechanical indicator + lockable front test button ❷ WTL - mechanical indicator + lockable front test button + light indicator (LED diode) WTD - mechanical indicator + lockable front test button + surge suppression element (diode) ❸ WTLD - mechanical indicator + lockable front test button + light indicator (LED diode) + surge suppression element (diode) ❸ ❷ WT - standard features of relays ❸ WTD, WTLD - available only in relays with DC coils Test buttons (no latching) and plugs need to ordered saparately. They substitute buttons type T. To exchange by Customer themselves. Information on test buttons (no latching) and plugs - page 10.
- Button R4P-0001-A - orange colour (AC coils)
- Button R4P-0001-D - green colour (DC coils)
- Plug R4W-0003-A - orange colour (AC coils)
- Plug R4W-0003-D - green colour (DC coils) R
www.relpol.com.pl 14.07.2014 Export Sales Department phone +48 68 47 90 832, 951 • e-mail: export@relpol.com.pl Plug-in sockets and accessories GZT3 For R3N Screw terminals Max. tightening moment for the terminal: 0,7 Nm 35 mm rail mount acc. to PN-EN 60715 or on panel mounting 76,3 x 27 x 42,5(80) mm Three poles
10 A, 300 V AC
DimensionsConnection diagram Accessories ❶ NC COM NO COIL GZT4-0035 Module type M... G4 1052GZT4-0040 ZGGZ4 ❷ In the bracket the height of socket with retainer / retractor clip is shown. GZM3 For R3N Screw terminals Max. tightening moment for the terminal: 0,7 Nm 35 mm rail mount acc. to PN-EN 60715 or on panel mounting 75 x 27 x 61(82) mm Three poles DimensionsConnection diagram Accessories ❶ NC COM NO COIL G4 1052 GZT4-0035 Module type M... GZT4-0040 ZGGZ4 Screw terminals plug-in socket Retainer / retractor clip Signalling / protecting module type M... Electromagnetic relay Description plate Removing the relay from the socket with a retrainer / retractor clip Mounting and sub-assemblies of the relay and accessories in the socket
www.relpol.com.pl 14.07.2014 Export Sales Department phone +48 68 47 90 832, 951 • e-mail: export@relpol.com.pl Signalling / protecting modules type M... ❷ When ordering modules indicate their color: gray or black. M21P M31R, M31G M32R, M32G M33R, M33G M51 M52 M53 M21N 6/230 V DC 6/24 V DC 24/60 V DC 110/230 V DC 6/24 V AC 24/60 V AC 110/240 V AC 6/230 V DC Module D (polarization P) It limits overvoltage on DC coils. Module LD (polarization P) It limits overvoltage on DC coils. Coil energizing indication. Module LD (polarization N) It limits overvoltage on DC coils. Coil energizing indication. Module RC It protects against EMC disturbance. It limits overvoltage. Module D (polarization N) It limits overvoltage on DC coils. M41R, M41G M42R, M42G M43R, M43G 6/24 V DC 24/60 V DC 110/230 V DC Module L Coil energizing indication. Module V It limits overvoltage on AC and DC coils. No indication. M61R, M61G M62R, M62G M63R, M63G 6/24 V AC/DC 24/60 V AC/DC 110/230 V AC/DC Module LV It limits overvoltage on AC and DC coils. Coil energizing indication. M91R, M91G M92R, M92G M93R, M93G 6/24 V AC/DC 24/60 V AC/DC 110/230 V AC/DC M71 M72 M73
24 V AC
130 V AC
230 V AC
It limits overvoltage on AC coils. M103 110/230 V AC VoltageModules type M... Layout Type of module ❶ ❷ MODULE type M... LED red – M...R LED green – M...G For sockets type: GZT80, GZM80, GZS80, GZMB80, GZT92, GZM92, GZS92, ES 32, GZT2, GZM2, GZMB2, GZT3, GZM3, GZT4, GZM4, GZMB4 Modules type M... are parallely connected with relay coil. Polarity P: -A1/+A2. Polarity N: +A1/-A2. PRECAUTIONS: 1. Ensure that the parameters of the product described in its specifi cation provide a safety margin for the appropriate operation of the device or system and never use the product in circumstances which exceed the parameters of the product. 2. Never touch any live parts of the device. 3. Ensure that the product has been connected correctly. An incorrect connection may cause malfunction, excessive heating or risk of fi re. 4. In case of any risk of any serious material loss or death or injuries of humans or animals, the devices or systems shall be designed so to equip them with double safety system to guarantee their reliable operation.
www.relpol.com.pl 14.07.2014 Export Sales Department phone +48 68 47 90 832, 951 • e-mail: export@relpol.com.pl Interconnection strips ZGGZ4 ❸ Interface relay PIR2 (PIR3, PIR4) is offered as a set: plug-in socket GZM2 (GZM3, GZM4) + miniature industrial relay R2N (R3N, R4N) + signalling / protecting module type M... + retainer / retractor clip GZT4-0040 + description plate GZT4-0035. Relays for plug-in sockets R2N R3N R4N Plug-in sockets GZT2 GZM2 GZT3 GZM3 GZT4 GZM4 Interface relays ❸ PIR2-...-00L. (R2N + GZM2) PIR3-...-00L. (R3N + GZM3) PIR4-...-00L. (R4N + GZM4) Interconnection strip ZGGZ4
- designed for the co-operation with plug-in sockets of miniature industrial relays and with interface relays PIR2, PIR3 and PIR4, which are equipped with screw terminals; sockets and relays are mounted on 35 mm rail mount acc. to PN-EN 60715,
- bridges common input signals (coil terminals A1 or A2) or output signals - see photo at the top,
- maximum permissible current is 10 A / 250 V AC,
- possibility of connection of 6 sockets or relays,
- colours of strips: ZGGZ4-1 grey, ZGGZ4-2 black. ZGGZ4 for: PIR2-...-00L. (R2N + GZM2) ZGGZ4
www.relpol.com.pl 14.07.2014 Export Sales Department phone +48 68 47 90 832, 951 • e-mail: export@relpol.com.pl Additional features for industrial relays Test buttons type T green – DC coils orange – AC coils R2N, R3N, R4N For industrial relaysType ❹ R2N, R3N, R4N, (R15 - 2 CO, 3 CO ❺) R2N, R3N, R4N, (R15 - 2 CO, 3 CO ❺) R2N, R3N, R4N, RY2, (R15 - 2 CO, 3 CO, 4 CO ❺) RUC, RUC-M R2N, R3N, R4N, RY2, (R15 - 2 CO, 3 CO, 4 CO ❺) (R15 - 2 CO, 3 CO ❺) (R15 - 4 CO ❺), RUC mechanical indicator lockable front test button, orange colour - AC coils, green colour - DC coils light indicator (LED diode), located inside the relay surge suppression element (diode) - only for DC coils surge suppression element (varistor) - only for AC coils test button without block function W T L D V K
Description
❹ Available combinations: WT, WTL, WTD, WTLD - in relays R2N, R3N, R4N for plug-in sockets L, D, LD - in relays RY2 for plug-in sockets WT, WTL, WTD, WTLD, WTV, WTLV - in relays R15 - 2 CO, 3 CO for plug-in sockets K, L, D, KL, KD, LD, KLD - in relays R15 - 4 CO for plug-in sockets K, L, KL - in relays RUC L - in relays RUC-M ❺ Voltage versions, in covers Industrial relays for plug-in sockets: R2N, R3N, R4N, R15 - 2 CO ❺, R15 - 3 CO ❺ with WT features as stan- dard (W - mechanical indicator + T - lockable front test button). Detailed information on additional features of individual relays can be found in the data sheets on the side of ”Ordering codes”.
www.relpol.com.pl 14.07.2014 Export Sales Department phone +48 68 47 90 832, 951 • e-mail: export@relpol.com.pl Test buttons (no latching) and plugs relays - for appli cations that do not allow permanent contact latching. By manual operation (pressing the button) relay contacts can get switched for as long time as long the button is pressed. Contacts return to initial position as soon as pressure is released from the button. Those operations can be done while the coil is deenergized. Button R4P-0001 or R15-M404 can be easily inserted by the Customer after removal of button type T (see Fig. 2). Button type T can be removed with screwdriver as shown on Fig. 1. Plugs R4W-0003 or R15-M203 can substitute button type T if manual operation (latching and testing) is not allowed. Changing button type T for plug can be done by Customer themselves in the same way as changing button type T for button (no latching). Fig. 1 Fig. 2 Dimensions - test button R4P-0001 Dimensions - test button R15-M404 Dimensions - plug R4W-0003 Dimensions - plug R15-M203 Types of buttons: R4P-0001-A - orange colour (AC coils) R4P-0001-D - green colour (DC coils) Types of buttons: R15-M404-A - orange colour (AC coils) R15-M404-D - green colour (DC coils) Types of plugs: R4W-0003-A - orange colour (AC coils) R4W-0003-D - green colour (DC coils) Types of plugs: R15-M203-A - orange colour (AC coils) R15-M203-D - green colour (DC coils)