R3G190-RD EBMPAPST | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
pfs @ rho=1,2 kg/m³ qv [m³/h] 9008007006005004003002001000 qv [CFM] 550500450400350300250200150100500 pfs [Pa] 1.100 1.050 1.000 950 900 850 800 750 700 650 600 550 500 450 400 350 300 250 200 150 100 pfs [InH2O] 4,4 4,2 3,8 3,6 3,4 3,2 2,8 2,6 2,4 2,2 1,8 1,6 1,4 1,2 0,8 0,6 0,4 0,2 Highlights: – Backward curved – 7-blade impeller, single phase motor – Output 10 VDC, max. 1.1 mA, Tach output, Control input 0-10 VDC / PWM – Motor current limit, Soft start, Locked-rotor protection – Over temperature protected electronics / motor – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharge holes: None, open rotor – Ingress protection of IP54 Material: Fiberglass reinforced composite Impeller: PA6 Direction of rotation: Clockwise, seen on rotor Series R3G190 RD Ø190 mm (1) Nominal data at operating point with maximum load. Nominal Data Air flow Nominal voltage Voltage range Hertz Ball bearings Power input Speed (1) Temperature range (1) Mass Ingress Protection Rating UL Type CFM VAC VAC Watts RPM oC g 12A A A A A A A A A A A A 16A A A A 12A A A A A A A A A A A A 16A A A A R3G190-RD47-04 Curves n rpm Pe W I A (115V) LwA dB(A) Measurement: LU-132500 Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LPA measured at 1m distance to fan axis. The values given are valid under the measuring conditions mentioned and may vary accoring to the actual installation situation. With any deviation to the standard set-up, the specific values have to be checked and reviewed once installed or fitted. For detailed information on the measuring set-up, please contact ebm-papst. 4440 161 2.30 81 4235 165 2.18 75 4120 169 2.25 72 4150 160 2.17 74 3700 93 1.24 77 3700 110 1.34 72 3700 125 1.62 70 3700 114 1.54 72 3000 50 0.67 73 3000 59 0.73 68 3000 67 0.88 65 3000 61 0.84 67 2300 22 0.31 67 2300 26 0.34 62 2300 30 0.41 59 2300 27 0.39 61 EC centrifugal fans - RadiCal®
Ø3.98(101) 3.46 (88+1) Connection line PVC 3G AWG20; 3 x brass lead tips crimped Ø2.91 (74) 0.08 (2) 2.46 (62.5) Ø0.18(4.5) 4X 0.24 (6) 3.35 (85 +10)17.72 (450 +20) 3.54 (90 +0.2) 0.05 (1.25) Depth of screw max. 10mm 2.28 (58 +0.2) Ø9.53 (170) Ø6.22 (158) Ø7.48 (190) Ø4.94 (125.5) Ø5.23 (132.8+0.2) 0.20 (5) 0.55 (14) 3.57 (90.7) Control line PVC 4X AWG22; 4 x brass lead tips crimped Accessory part: Inlet nozzle 09576-2-4013, not included in the standard scope of delivery Depth of screw max. 5mm R3G190-RDXX-XX Druck p f s[Pa]für Rho=1,2kg/m^3 qv[m^3/h] 1.1001.0009008007006005004003002001000 qv[cfm] 7006005004003002001000 ]aP[sf p 1.250 1.200 1.150 1.100 1.050 1.000 950 900 850 800 750 700 650 600 550 500 450 400 350 300 250 200 150 100 pfs_E[IN H2O] 5,2 4,8 4,6 4,4 4,2 3,8 3,6 3,4 3,2 2,8 2,6 2,4 2,2 1,8 1,6 1,4 1,2 0,8 0,6 0,4 0,2 0]aP[sf p ]aP[sf p ]aP[sf p ]aP[sf p Measurement: LU-142350 Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side noise levels: LWA as per ISO 13347, LPA measured at 1m distance to fan axis. The values given are valid under the measuring conditions mentioned and may vary accoring to the actual installation situation. With any deviation to the standard set-up, the specific values have to be checked and reviewed once installed or fitted. For detailed information on the measuring set-up, please contact ebm-papst. R3G190-RD45-03 Curves n rpm Pe W I A (230V) LwA dB(A) 12A A A A A A A A A A A A 16A A A A 12A A A A A A A A A A A A 16A A A A B B B B B B B B B B B B B B B B 4555 161 1.35 81 4470 170 1.35 75 4180 170 1.35 72 4260 170 1.35 74 3800 96 0.81 77 3800 105 0.93 72 3800 127 1.06 71 3800 120 0.97 72 3100 52 0.43 73 3100 57 0.50 68 3100 69 0.57 65 3100 65 0.52 67 2400 24 0.19 67 2400 26 0.22 62 2400 32 0.26 59 2400 30 0.23 61