R2005350L PDI | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
Si Reverse, low current, 5 – 200MHz, 35.2dB typ. Gain @ 200MHz, 140mA max. @ 24VDC Page 1 of 4 2004 Jun 01 Document Revision Level B
FEATURES
- Excellent linearity
- Superior return loss performance
- Extremely low distortion
- Optimal reliability
- Low noise
- Unconditionally stable under all terminations APPLICATION
- 5 to 200 MHz CATV amplifier for reverse channel systems
DESCRIPTION
- Hybrid reverse amplifier employing silicon dice LIMITING VALUES In accordance with the Absolute Maximum Rating System (IEC 60134) SYMBOL PARAMETER MIN. MAX. UNIT Vi RF input voltage (single tone) - 50 dBmV Vov DC supply over-voltage (5 minutes) - 30 V Tstg storage temperature - 40 + 100 °C Tmb operating mounting base temperature - 30 + 100 °C CHARACTERISTICS Table 1: S-Parameter, Noise Figure, DC Current; V B = 24V; Tmb = 30°C; ZS = ZL = 75 Ω SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT f = 5 MHz 34.5 35.1 35.5 dB Gp power gain f = 200 MHz 34.5 35.2 36.0 dB SL slope 1) f = 5 to 200 MHz -0.2 0.1 0.5 dB FL flatness of frequency response f = 5 to 200 MHz -0.1 0.5 dB S11 input return loss f = 5 to 200 MHz 20.0 - dB S22 output return loss f = 5 to 200 MHz 20.0 - dB S12 reverse isolation f = 5 to 200 MHz - -42.0 dB F noise figure f = 5 to 200 MHz - 5.0 dB Itot total current consumption (DC) 140.0 160.0 mA Notes: 1) The slope is defined as the difference between the gain at the start frequency and the gain at the stop frequency. R2005350L Si Reverse Hybrid , low current 5 – 200 MHz 35.2dB typ. Gain @ 200MHz 140mA max. @ 24VDC
Si Reverse, low current, 5 – 200MHz, 35.2dB typ. Gain @ 200MHz, 140mA max. @ 24VDC Page 2 of 4 2004 Jun 01 Document Revision Level B CHARACTERISTICS Table 2: Distortion data 5 – 200 MHz; V B = 24V; Tmb = 30°C; ZS = ZL = 75 Ω SYMBOL PARAMETER CONDITION MIN. TYP. MAX. UNIT CTB composite triple beat 7 ch. flat; Vo = 50 dBmV 1) 28 ch. flat; Vo = 50 dBmV 4) - - 72 - 57 dBc XMOD cross modulation 7 ch. flat; Vo = 50 dBmV 1) 28 ch. flat; Vo = 50 dBmV 4) - - 64 - 50 dB CSO composite second order distortion 7 ch. flat; Vo = 50 dBmV 1) 28 ch. flat; Vo = 50 dBmV 4) - - 72 - 66 dBc d2 second order distortion 2) - 70 dBc V0 output voltage Dim = -60 dB 3) 62.0 - dBmV Notes: 1) 7 channels, NTSC frequency raster: T7 – T13 (7.0 to 43.0 MHz), +50 dBmV flat output level. 2) f 1 = 83.25 MHz; V1 = 50 dBmV; f2 = 109.25 MHz; V2 = 50 dBmV; fTEST = f1 + f2 = 192.5 MHz. 3) f 1 = 187.25 MHz; V1 = 50 dBmV; f2 = 194.25 MHz; V2 = V1 – 6dB; f3 = 196.25 MHz; V3 = V1 – 6dB; f TEST = f1 + f2 - f3 = 185.25 MHz, according to DIN45004B. 4) 28 channels, NTSC frequency raster: T7 – T13 plus 2-6 (55.25 to 83.25 MHz) and A2 – 11 (109.25 - 199.25), +50 dBmV flat output level. Composite Second Order (CSO) The CSO parameter (both sum and difference products) is defined by the NCTA. Composite Triple Beat (CTB) The CTB parameter is defined by the NCTA. Cross Modulation (XMOD) Cross modulation (XMOD) is measured at baseband (selective voltmeter method), referenced to 100% modulation of the carrier being tested.
Si Reverse, low current, 5 – 200MHz, 35.2dB typ. Gain @ 200MHz, 140mA max. @ 24VDC Page 3 of 4 2004 Jun 01 Document Revision Level B 123 4 5 6 789INPUT GND GND +VB GND GND OUTPUT Pinning: min max A4 4 , 4 4 4 , 8 B1 3 , 4 1 3 , 8 C1 9 , 9 2 0 , 9 D 7,85 8,15 E 12,45 12,75 F3 7 , 9 3 8 , 3 G 3,95 4,2 H3 , 8 4 , 2 I2 5 , 2 2 5 , 6 J- - K4 , 0 4 , 4 L2 7 , 0 2 7 , 4 M1 1 , 1 1 2 , 1 N5 , 4 6 , 2 O 0,23 0,27 P 0,42 0,48 Q 2,24 2,84 R 2,04 3,04 S 2,29 2,79 T 4,83 5,33 U 4,83 5,33 nominal 44,6 ±0 , 2 13,6 ±0 , 2 20,4 ±0 , 5 8 ±0 , 1 5 12,6 ±0 , 1 5 38,1 ±0 , 2 4 ±0 , 2 25,4 ±0 , 2 4 +0,2 / -0,05 UNC 6-32 4,2 ±0 , 2 27,2 ±0 , 2 11,6 ±0 , 5 5,8 ±0 , 4 0,25 ±0 , 0 2 0,45 ±0 , 0 3 2,54 ±0 , 3 2,54 ±0 , 5 2,54 ±0 , 2 5 5,08 ±0 , 2 5 5,08 ±0 , 2 5 All Dimensions in mm: European Projection Notes: 51 0 m m0 scale 123 5 789 R O Q M 51 0 m m0 scale B N L F A D H øG T S PJ U I E C K
Si Reverse, low current, 5 – 200MHz, 35.2dB typ. Gain @ 200MHz, 140mA max. @ 24VDC Page 4 of 4 2004 Jun 01 Document Revision Level B DEFINITIONS Data Sheet Status Objective Product Specification This data sheet contains target or goal specifications for product development. Preliminary Product Specification This data sheet contains preliminary data; supplementary data may be published later. Product Specification This data sheet contains final product specifications. Limiting values Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 60134). Stress above one or more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of the specification is not implied. Exposure to limiting values for extended periods may affect device reliability.
Application information
Where application information is given, it is advisory and does not form part of the specification. Premier Devices reserves the right to make changes without further notice to any products herein. Premier Devices makes no warranty representation or guarantee regarding the suitability of its products for any particular purpose, nor does Premier Devices assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including wit hout limitation consequential or incidental damages. “Typical” parameters which may be provided in Premier Devices datashee ts and/or specifications c an and do vary in different applications and actual performance may vary over time. A ll operating parameters, including “Typicals” must be validated for each customer application by customer´s technical exper ts. Premier Devices does not convey any license under its patent rights nor the rights of others. Premier Devices pr oducts are not designed, intended, or authorized for use as components in systems intended for surgical implant into the bod y, or other applications intended to support or sustain life, or for any other application in which the failure of the Pr emier Devices product could create a situation where personal injury or death may occur. Should Buyer purchase or use Premier Devices products for any such unintended or unauthorized application, Buyer shall indemnify and hold Prem ier Devices and its officers , employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, and claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that Premier Devices was negligent regarding the design or manufacture of the part. © Premier Devices Germany GmbH 2004 How to contact us: Premier Devices Germany GmbH Loeffelholzstrasse 20, D-90441 Nuernberg, Germany Phone: +49 (0) 911 9411 233, FAX: +49 (0) 911 9411 198, Email: sales.germany@premierdevices.com , Internet: http://www.premierdevices.de/