LR600240A25-120 SENSATA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 4

Technical content

Features

  • Ratings up to 40 A @ 600 VAC with external heat sink
  • SCR output for heavy industrial loads
  • AC or DC control
  • Zero voltage (resistive loads) or instantaneous turn-on (inductive loads) output
  • Optional mounting clip available (LMC-1) SPECIFICATIONS Control Voltage 25 A 40 A 25 A 40 A 25 A 40 A 90-140 VAC LR600240A25-120 LR600240A40-120 LR1200480A25-120 LR1200480A40-120 LR1200600A25-120 R1200600A40-120 180-260 VAC LR600240A25-240 LR600240A40-240 LR1200480A25-240 LR1200480A40-240 LR1200600A25-240 LR1200600A40-240 4-32 VDC LR600240D25 LR600240D40 LR1200480D25 LR1200480D40 LR1200600D25 LR1200600D40 PRODUCT SELECTION Description 25A 40A 25A 40A 25A 40A Operating Voltage Range (47-63 Hz) [Vrms] 24-280 24-280 48-530 48-530 48-600 48-600 Transient Overvoltage [Vpk] 600 600 1200 1200 1200 1200 Maximum Off-State Leakage Current @ Rated Voltage [mArms] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/ μsec] (3) 500 500 500 500 500 500 Maximum Load Current [Arms] 25 40 25 40 25 40 Maximum Surge Non-Repetitive (16.6 msec)[Apk] 250 400 250 400 250 40 Maximum I² t for Fusing (8.33 msec) [A² sec] 260 660 260 660 260 660 Maximum Thermal Resistance Junction to Ceramic Base Output (1)

www.sensata.comCopyright © 2024 Sensata Technologies, Inc. Description No Suffix -120 -240 Control Voltage Range 4-32 VDC 90-140 VAC 180-260 VAC Must Turn-On Voltage 4.0 VDC 90 VAC 180 VAC Must Turn-Off Voltage 1.0 VDC 10 VAC 10 VAC Typical Input Current [mA] (5)(6) 9 15 11 Maximum Turn-on Time (4) 1/2 Cycle 10 10 Maximum Turn-off Time 1/2 Cycle 40 40 Input (1) Description Parameters Dielectric Strength, Input/Output/Base (50/60 Hz) 2500 Vrms Minimum Insulation Resistance (@ 500 VDC) 109 Ohms Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range -30 to 80 °C Ambient Storage Temperature Range -30 to 125 °C Weight (typical) 0.5 oz. (14.4 g) Encapsulation Thermally Conductive Epoxy General (1) THERMAL DERATE INFORMATION MECHANICAL DIMENSIONS Tolerance: ±0.02 in / 0.5 mm All dimensions are in inches [millimeters] 1.37 [34.8] 1.0 [25.4] 0.78 [19.8] 1.12 [28.4] 0.50 [12.7] 0.50 TYP . [1.2] 0.37 [9.4] 0.25 [6.3]

www.sensata.comCopyright © 2024 Sensata Technologies, Inc. 1.73 [43.9] 1.28 [32.5] 1.02 [25.9] 0.110 [2.79] DIA. 1.28 [32.5] 1.40 [35.5] 1.65 [41.9] 2.05 [52.0] 1.25 [31.7] 1.02 [25.9] .068 [1.72] .007 [0.17] 1.14 [28.5] 1.39 [35.3] 0.12 [3.04] .245 [6.22] Mounting Clip (Optional) NOTE: This plastic shell is designed to secure LR Series Solid State Relay to the surface of external heat sink. LMC-1 Mounting Clip ORDERING OPTIONS Example : LR600240A25R-120 Blocking Voltage Operating Voltage Series Control Voltage Rated Load Current LR LR 600 240 A 25 R D: DC Input A: AC Input 600: 600 Vpk 1200: 1200 Vpk 240: 24-280 VAC 480: 48-530 VAC 600: 48-600 VAC 25: 25 Amps 40: 40 Amps Switching Type AC Control Range Blank: 4-32 VDC (DC Only) -120: 90-140 VAC (AC Only) -240: 180-260 VAC (AC Only) -120 Required for valid part number For options only and not required for valid part number Blank: Zero voltage Turn-on R: Instantaneous Turn-on

Rev:07/15/24 www.sensata.com CONTACT USCopyright © 2024 Sensata Technologies, Inc. Datasheets provided by Sensata Technologies, Inc., its subsidiaries and/or affiliates (“Sensata”) are solely intended to assist third parties (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, valuation, and judgment in designing Buyer’s systems and products. Sensata datasheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular datasheet. Sensata may make corrections, enhancements, improvements, and other changes to its datasheets or components without notice. Buyers are authorized to use Sensata datasheets with the Sensata component(s) identified in each particular datasheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATASHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATASHEETS OR USE OF THE DATASHEETS, EXPRESS, IMPLIED, OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATASHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com. SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY , AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA Americas +1(800) 350 2727 sales.crydom@sensata.com Europe, Middle East & Africa +44 (1202) 416170 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE

  • The product’s side panels may be hot, allow the product to cool before touching
  • Follow proper mounting instructions including torque values
  • Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
  • Disconnect all power before installing or working with this equipment
  • Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury. Designed in accordance with the requirements of IEC 62314 AGENCY APPROVALS & CERTIFICATIONS GENERAL NOTES (1) All parameters at 25 °C and per section unless otherwise specified (2) Dielectric and insulation resistance are measured between input and output. (3) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 (4) Turn-on time for instantaneous turn-on models is 0.1 ms (5) DC input circuity incorporates active current limiter. (6) Use suffix -120 for 120 VAC control and -240 for 240 VAC control. E116950