The S ure Cross® Temperature and Temperature/ Humidity S ensor works in a variety of environments to provide temperature and humidity measurements.

  • M anufactured with a robust metal housing
  • Connects via a 1-wire serial interface
  • Designed to work with FlexPower 1-Wire S erial Interface Node models DX80N9X1S -P6 and DX80N2X1S -P6, the 10 to 30 V dc powered 1-Wire S erial Interface N ode models DX80N9X6S -P6 and DX80N2X6S -P6, MultiHop M -H6 and M -H6L radios, and the Wireless Q45 S ensor Nodes DX80N2Q45TH and DX80N9Q45TH
  • S hips with aluminum grill filter cap; optional stainless steel 10 micrometer sintered filter available separately WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device does not include the self-checking red undant circuitry necessary to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor ou tput condition. For additional information, updated documentation, and a list of accessories, refer to Banner Enginee ring's website, www.bannerengineering.com/ wireless . Configure this sensor using the S ensor Configuration Tool and adapter cable BWA-US B1WIRE-001 (datasheet 170020). Banner Humidity S ensor Calibration S tatement. This calibration statement (also available online) lists the chain with which the calibration of Banner humidity sensors is traceable to NIS T st andards. A Certificate of Factory Calibration ships with every temperature/ humidity or temperature sensor. Although your certificate will be specific to your product, a sample certificate is available for download . M odels M odel Power Requirements I/ O M 12FTH4Q 3.6 to 5.5 V dc Temperature and relative humidity via a 1-wire serial interface M 12FT4Q Temperature via a 1-wire serial interface Sensor Configuration Tool The S ensor Configuration Tool offers an easy way to manage sensor parameters, retrieve data, and visually show sensor data from a number of different sensors. The S ensor Configuration Tool software runs on any Windows machine and uses an adapter ca ble to connect the sensor to your computer. Download the most recent version of the S ensor Configuration Tool from Banner Engineering's website: www.bannerengineering.com/ wireless. The S ensor Configuration Tool currently supports the following sensors: Sensor Type M odel USB Adapter Cable Temperature and Humidity M 12FTH3Q and M 12FT3Q M odel B WA-HW-006: US B-to-RS -485 adapter cable M 12FTH4Q and M 12FT4Q M odel BWA-US B1WIRE-001: US B-to- RS -232 1-Wire adapter cable Vibration and Temperature QM 42VT1 M odel BWA-US B1WIRE-001: US B- to-RS -232 1-Wire adapter cable QM 42VT2 M odel BWA-HW-006: US B-to-RS -485 adapter cabl e GPS GPS 50M M odel BWA-HW-006: US B-to-RS -485 adapter ca ble AND a field-wireable M 12/ Euro-style connector or connecter with pigtail U-GAGE K50U Ultrasonic K50UX1RA M odel BWA-US B1WIRE-00 1: US B-to-RS -232 1-Wire adapter cable K50UX2RA M odel BWA-HW-006: US B-to-RS -485 adapter cab le Launch the S ensor Configuration Tool and from the drop-down list, select your sens or type and click OK. Sure Cross® Temperature and Humidity Sensor Original Document 162669 Rev. G

16 November 2017

Connecting the Temperature/ Humidity Sensor To install the sensor to a device with a 5-pin Euro -style female end, follow these instructions: 1. Align the notch in the female connector with the key in the sensor’s male connector. 2. Gently slide the sensor end into the connector. 3. Rotate the threaded nut to tighten the sensor down. DO NOT attempt to rotate the sensor after it is connected to the device or the cable end because this will damage the sensor. Female end Threaded nut Male end Wiring This sensor is designed to be plugged directly into compatible Nodes. The Node powers the sensor and periodically requests data using the 1-wire serial interface. Refer to the Class I D ivision 2 control drawings (p/ n 143086) for wiring specifications or limitations. 5-pin M 12/ Euro-style Connector (M ale) Pin Wire Color S ensor Connection 1 Brown Power IN (+), 3.6 to 5.5 V dc

2 White 1-Wire serial device select (sinking input to sensing device)

3 Blue Ground (-)

4 Black Not used/ reserved

5 Gray 1-Wire serial communications

The temperature = (Holding register value) ÷ 20. Sensor Register Output Type I/ O Range Holding Register Representation M in M ax M in (Dec) M ax (Dec) 1 Humidity (%RH) 1 0 100.00% 0 10,000 2 Temperature (°C) –1638.4 1638.3 –32768 32767 3 Temperature (°F) –1638.4 1638.3 –32768 32767 1 Only available on the M 12FTH4Q model. Humidity sens or is not included with the M 12FT4Q model. S ure Cross® Temperature and Humidity S ensor 2 www.bannerengineering.com - Tel: +1-763-544-3164 P/ N 162669 Rev. G

3.6 to 5.5 V dc Current Default sensing: 28 µAmps Disabled sensing: 15 µAmps Active comms: 4.7 mA Mounting Threads M 12 × 1 Indicators Green flashing: Power ON Red flicker: S erial Tx Communication Hardware Interface: 1-wire serial interface Baud rates: 9.6k, 19.2k (default), or 38.4k Data format: 8 data bits, no parity (default), 1 st op bit (even or odd parity available) Communication Protocol S ure Cross DX80 S ensor Node 1-Wire S erial Interface Communications Line Level Receive ON: Greater than 2 V Level Receive OFF: Less than 0.7 V Level Transmit ON: 2.7 to 3 V Level Transmit OFF: 0 V (pulldown resistor of 10 kO hm Compatible Nodes

900 M Hz M odels

2.4 GHz M odels

Humidity measurements are only available with the M 12FTH4Q model. The M 12FT4Q model does not include the humidity sensor. M easuring Range: 0 to 100% relative humidity Resolution: 0.1% relative humidity Accuracy: 25 °C: ±2% 0 °C to 70°C and 10–90%: ±3% 0 °C to 70°C and 0–10 % or 90–100 %: ± 7% Temperature M easuring Range: –40 °C to +85 °C (–40 °F to +185 °F) Resolution: 0.1 °C Accuracy Environmental Rating IEC IP67; NEM A 6 Operating Temperature Shock and Vibration IEC 68-2-6 and IEC 68-2-27 S hock: 30g, 11 millisecond half sine wave, 18 shock s Vibration: 0.5 mm p-p, 10 to 60 Hz Certifications CS A: Class I, Division 2, Groups A, B, C, D — Certificate 1921239 Refer to the Class I Division 2 control drawings (p / n 143086) for wiring specifications or limitations. All battery-powered devices must only use the lithium battery manufactured by Xeno, model XL-205F. Accessories Temperature-Humidity Filter Caps FTH-FIL-001

  • Aluminum grill filter cap (factory default, ships with M 12FT* Q sensors) FTH-FIL-002
  • S tainless steel, sintered to 10 micrometer porosity (for high dust environments.) Euro-Style Cordsets - Double Ended When using the FlexPower Node with integrated battery, use a double ended cordset. When using a FlexPower Node with external power supply, use a single ended cordset. If using the communication lines, the cable length cannot exceed 3 meters (10 ft). 2 Operating the devices at the maximum operating conditions for extended periods can shorten the life of the d evice. S ure Cross® Temperature and Humidity S ensor P/ N 162669 Rev. G www.bannerengineering.com - Tel: +1-763-544-3164 3

5-Pin Threaded M 12/ Euro-Style Cordsets—Double Ended and Less Than 3 m Long M odel Length Style Dimensions Pinout DEE2R-51D 0.31 m (1 ft) Female S traight/ M ale S traight 40 Typ. ø 14.5 M12 x 1 44 Typ. ø 14.5 M12 x 1 M ale Female 1 = Brown 2 = White 3 = Blue 4 = Black 5 = Green/ Yellow DEE2R-53D 0.91 m (3 ft) DEE2R-58D 2.44 m (8 ft) Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to b e free from defects in material and workmanship for one year following the date of shipment. Banner En gineering Corp. will repair or replace, free of charge, any product of its manufac ture which, at the time it is returned to the factory, is found to have be en defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the impro per application or installation of the Banner product. THIS LIM ITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IM PLIED (INCLUDING, WITHOUT LIM ITATION, ANY WARRANTY OF M ERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORM ANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or , at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAM AGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to chan ge, modify or improve the design of the product wit hout assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse , abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the pr oduct warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com . S ure Cross® Temperature and Humidity S ensor © Banner Engineering Corp. All rights reserved