L-GAGE™ Q50 Series with Complementary Discrete Outputs LED-Based Linear Displacement Sensor with Complementary Discrete Outputs and TEACH-Mode Programming Printed in USA 01/02 P/N 65741 rev. A L-GAGE Q50 Complementary Discrete Output Sensor Features
- Cost-effective LED-based complementary-discrete sensor
- Fast, easy-to-use TEACH-Mode programming; no potentiometer adjustments
- Models available with either 4 or 48 millisecond response speed
- Models available with either visible red or infrared beam
- T each a sensing window (2 switch points) or teach single switch point (adjustable field mode)
- T wo sensing ranges, depending on model: 100 to 300 mm (visible red beam models), and 100 to 400 mm (infrared beam models)
- Good color sensitivity
- Remote TEACH input for security and convenience
- T wo bicolor Status LEDs
- Choose 2 meter or 9 meter unterminated cable, or swivel 5-pin Euro-style QD connector
- Rugged construction withstands demanding sensing environments; rated IEC IP67, NEMA 6 L-GAGE Q50 Complementary Discrete Output Sensor Models Model Number Sensing Range Cable* Supply Voltage Beam Response Time * 9 meter cables are available by adding suffix “ W/30” to the model number of any cabled sensor (e.g., Q50BVN W/30). A model with a QD connector requires a mating cable; see page 8. Q50BVN 100 to 300 mm (3.9" to 11.8") 5-wire, 2 m (6.5') cable 12 to 30V dc Visible Red LED 48 ms Q50BVNQ 5-pin Euro-style QD Q50BVNY 5-wire, 2 m (6.5') cable 4 ms Q50BVNYQ 5-pin Euro-style QD Q50BVP 5-wire, 2 m (6.5') cable 48 ms Q50BVPQ 5-pin Euro-style QD Q50BVPY 5-wire, 2 m (6.5') cable 4 ms Q50BVPYQ 5-pin Euro-style QD Q50BN 100 to 400 mm (3.9" to 15.7") 5-wire, 2 m (6.5') cable Infrared LED 48 ms Q50BNQ 5-pin Euro-style QD Q50BNY 5-wire, 2 m (6.5') cable 4 ms Q50BNYQ 5-pin Euro-style QD Q50BP 5-wire, 2 m (6.5') cable 48 ms Q50BPQ 5-pin Euro-style QD Q50BPY 5-wire, 2 m (6.5') cable 4 ms Q50BPYQ 5-pin Euro-style QD Output Complementary NPN Complementary NPN Complementary PNP Complementary PNP
Banner Engineering Corp. • Minneapolis, MN U.S.A. see Figure 8 for suggested mounting orientations. Figure 8. Sensor orientations for typical targets
L-GAGE Q50 Complementary Discrete Output Sensor Specifications L-GAGE Q50 – Complementary Discrete Output Sensor page 6 Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 Q50B: 100 to 400 mm (3.9" to 15.7")Sensing Range Sensing Repeatability Output Protection Supply Voltage 12 to 30V dc (10% maximum ripple); 70 mA max. (exclusive of load) Supply Protection Circuitry Protected against reverse polarity and transient overvoltages Delay at Power-up 2 seconds Sensing Beam Wave length Q50BV: 685 nm (typical) Q50B: 880 nm (typical) Beam Size Q50BV: 20 mm dia. (max.) Q50B: 20 mm dia. (max.) Output Rating Complementary Discrete Output 150 mA maximum, per output OFF-state leakage current: Less than 10 micro-amps ON-state saturation voltage: Less than 1V @ 10 mA and less than 1.5V @ 100 mA Protected against false pulse on power-up and continuous overload or short circuit of outputs Output Response Time 2-second delay on power-up Fast: 4 ms ON, 4 ms OFF Slow: 48 ms ON, 48 ms OFF Slow Response (Q50B): 0.5% of sensing distance Fast Response (Q50B...Y): 1.0% of sensing distance Output Hysteresis See Figure 3 Color Sensitivity (typical) See Figure 4 Q50BV: 100 to 300 mm (3.9" to 11.8") Remote Teach Input Impedance 15 kΩ Remote Teach Input To Teach: Connect gray wire to +5 to 30V dc To Disable: Connect gray wire to 0 to +2V dc (or open connection) Adjustments Sensing Window Limits: TEACH-mode programming of near and far window limits may be set using the Teach push button or remotely via the gray Teach wire. Indicators Range LED Green — Target is within sensing range Indicator Red — Target is outside sensing range (green/red) Flashing Green – Outputs are overloaded OFF — Sensor Power OFF Teach/Output Yellow (window limits) — Target is within taught limits LED Indicator Yellow (fixed field) — Target is closer than cutoff limit (yellow/red) OFF — Target is outside taught window limits Red — Sensor is in TEACH mode Minimum Taught Window (millimeters) Model Number Ambient Light Immunity <10,000 Lux Output Configuration SPDT (complementary) solid-state dc switch. Choose NPN (current sinking) or PNP (current sourcing) outputs. Q50B..Y Q50B.. Q50BV..Y Q50BV.. Distance 100 mm 150 mm 200 mm 250 mm 300 mm 350 mm 400 mm ––75.03.52.01 ––1410742 151075.03.52.01 30201410742
L-GAGE Q50 Complementary Discrete Output Sensor Specifications (continued) L-GAGE Q50 Dimensions L-GAGE Q50 – Complementary Discrete Output Sensor page 7 Banner Engineering Corp. • Minneapolis, MN U.S.A. www.bannerengineering.com • Tel: 763.544.3164 19.7 mm (0.77") 60.0 mm (2.36") 4.0 mm (0.16") 4.0 mm (0.16") 41.8 mm (1.65") 52.0 mm (2.05") 77.0 mm (3.03") 49.8 mm (1.96") 67.3 mm (2.65") 2x ø3.4 mm (0.13")25 mm (0.98") 15 mm (0.59") 15 mm (0.59") RANGE IN OUT TEACH OUTPUT s To Set NEAR and FAR Limits. 1. Press and hold Teach button until the Teach light turns on (RED) 2. Adjust target to 1st limit position. Press Teach button. (Teach flashes) 3. Adjust target to 2nd limit position. Press Teach button (Teach turns off) Emitter Receiver Q50BNQ L-GAGE ™ RANGE: 100 - 400 mm Load bu 12-30V dc Output 2 Output 1 Teach +5-30V dc bn bk wh gy Load Q50BN L-GAGE™ RANGE: 100 - 400 mm Load bu 12-30V dc Output 2 Output 1 +5-30V dc Bare bn bk wh gy Load Load bu 12-30V dc Output 2 Output 1 +5-30V dc Bare bn bk wh gy Load Load bu 12-30V dc Output 2 Output 1 Teach +5-30V dc bn bk wh gy Load Load bn 12-30V dc Output 2 Output 1 +5-30V dc Bare bu bk wh gy Load Load bn 12-30V dc Output 2 Output 1 Teach +5-30V dc bu bk wh gy Load Connections 2 m or 9 m 5-conductor PVC-covered attached cable or 5-pin Euro-style quick disconnect Construction Housing: Molded ABS/Polycarbonate Window Lens: Acrylic Environmental Rating IEC IP67, NEMA 6 Vibration and Mechanical Shock All models meet Mil. Std. 202F requirements. Method 201A (Vibration: 10 to 60Hz max. double amplitude 0.06", maximum acceleration 10G). Also meets IEC 947-5-2 requirements: 30G, 11 ms duration, half sine wave. Operating Conditions Temperature: -10° to +55°C (+14° to +131°F) Max. Rel. Humidity: 90% at +50°C (non-condensing) Application Notes Allow 15-minute warm-up for maximum performance. Hardware M3 hardware is included. L-GAGE Q50 Hookups NPN Hookups Cabled Models Quick-Disconnect Models PNP Hookups Cabled Models Quick-Disconnect Models
Euro-Style Quick-Disconnect Cables L-GAGE Q50 – Complementary Discrete Output Sensor WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied. Accessories Mounting Brackets SMBQ50 • Right-angle bracket
- 14-ga., 304 Stainless Steel 67.0 mm (2.63") 1.9 mm (0.07") 53.0 mm (2.09")4.0 mm (0.16") 4.0 mm (0.16") 3x ø3.9 mm (0.16") 8.0 mm (0.32") 42.0 mm (1.65") 45° 15.0 mm (0.60") 7.0 mm (0.28") R 66.7 mm (2.63") 38.8° 32.5 mm (1.28")4.2 mm (0.17") 10.0 mm (0.39") 1.9 mm (0.07") 20.0 mm (0.79") 3x R2.25 mm (0.09") R24.1 mm (0.95") 10° White Wire Blue Wire Black Wire Brown Wire Gray Wire 5-Pin Euro Straight MQDEC2-506 MQDEC2-515 MQDEC2-530 2 m (6.5') 5 m (15') 9 m (30') Style Model Length Connector Pin-out M12 x 1 ø 15 mm (0.6") 44 mm max. (1.7") 5-Pin Euro Right- angle MQDEC2-506RA MQDEC2-515RA MQDEC2-530RA 2 m (6.5') 5 m (15') 9 m (30') 38 mm max. (1.5") M12 x 1 ø 15 mm (0.6") 38 mm max. (1.5") WARNING . . . Not To Be Used for Personnel Protection Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death. These sensors do NOT include the self- checking redundant circuitry necessary to allow their use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection.