Self-contained, dc-operated sensors

  • Featuring EZ-BEAM ® technology for reliable sensing without the need for adjustments
  • Rectangular 40 mm plastic housing with 30 mm threaded mounting base in opposed, retroreflective or fixed-field modes
  • Completely epoxy-encapsulated to provide superior durability, even in harsh sensing environments rated to IP69K
  • Innovative dual-indicator system for simple sensor performance monitoring
  • Advanced diagnostics to warn of marginal sensing conditions or output overload
  • 10 to 30 V dc; choose SPDT (complementary) NPN or PNP outputs (150 mA maximum each) WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Models Model1 Sensing Mode Range LED Output Q406E OPPOSED Opposed 60 m (200 ft) Infrared, 950 nm Q40SN6R NPN Q40SP6R PNP Q40SN6LP P POLAR RETRO Polarized Retro-reflective 6 m (20 ft) Visible red, 680 nm NPN Q40SP6LP PNP Q40SN6FF200 FIXED-FIELD Fixed Field 200 mm (8 in) cutoff Infrared, 880 nm NPN Q40SP6FF200 PNP Q40SN6FF400 400 mm (16 in) cutoff NPN Q40SP6FF400 PNP Q40SN6FF600 600 mm (24 in) cutoff NPN Q40SP6FF600 PNP Fixed-Field Mode Overview Q40 Series self-contained fixed-field sensors are small, powerful, infrared diffuse mode sensors with far-limit cutoff (a type of background suppression). Their high excess gain and fixed-field technology allow detection of objects of low reflectivity, while ignoring background surfaces. The cutoff distance is fixed. Backgrounds and background objects must always be placed beyond the cutoff distance. 1 Standard 2 m (6.5 ft) cable models are listed.
  • To order 9 m (30 ft) cable: add suffix "W/30" (for example, Q406E W/30).
  • To order 4-pin Euro-style QD models: add suffix "Q" (for example, Q406EQ). A model with a QD connector requires a mating cable. Q40 Sensors: dc-Voltage Series Original Document 121516 Rev. A

14 March 2017

Figure 3. Reflective Background - Problem Figure 4. Reflective Background - Solution in this axis and direction may cause a false sensor response. Figure 5. Object Beyond Cutoff - Problem Figure 6. Object Beyond Cutoff - Solution behavior is known as color sensitivity. cutoff model, for example; and 190 mm represents the cutoff for this sensor and target.

4 Load

Note: QD hookups are functionally identical. Alarm Hookup 10-30V dc Alarm Load Alarm Hookup 10-30V dc Alarm Load Specifications Supply Voltage and Current 10 to 30 V dc (10% max. ripple) Supply current (exclusive of load current): Emitters: 25 mA Receivers: 20 mA Polarized Retroreflective: 30 mA Fixed-Field: 35 mA Supply Protection Circuitry Protected against reverse polarity and transient voltages Output Configuration SPDT solid-state dc switch; Choose NPN (current sinking) or PNP (current sourcing) models Light Operate: N.O. output conducts when sensor sees its own (or the emitter's) modulated light Dark Operate: N.C. output conducts when the sensor sees dark; the N.C. (normally closed) output may be wired as a normally open marginal signal alarm output, depending upon hookup to power supply (U.S. patent 5087838) Output Rating 150 mA maximum (each) in standard hookup. When wired for alarm output, the total load may not exceed 150 mA. OFF-state leakage current: < 1 microamp at 30 V dc ON-state saturation voltage: < 1V at 10 mA dc; < 1.5 V at 150 mA dc Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. Supply Wiring (AWG) Required Overcurrent Protection (Amps) 20 5.0 22 3.0 24 2.0 26 1.0 28 0.8 30 0.5 Output Protection Circuitry Protected against false pulse on power-up and continuous overload or short circuit of outputs Output Response Time Opposed mode: 3 ms ON, 1.5 ms OFF Retro and Fixed-Field: 3 ms ON and OFF Note: 100 ms delay on power-up; outputs do not conduct during this time. Repeatability Opposed mode: 375 μ s Retro and Fixed-Field: 750 μ s Repeatability and response are independent of signal strength Indicators Two LEDs (Green and Amber) Green ON steady: power to sensor is ON Green flashing: output is overloaded Amber ON steady: N.O. output is conducting Amber flashing: excess gain marginal (1 to 1.5x) in light condition Construction PBT polyester housing; acrylic lens Environmental Rating Leakproof design rated NEMA 6P, IEC IP67. QD Models rated IEC IP69K per DIN 40050-9. Connections 2 m (6.5 ft) or 9 m (30 ft) attached cable, or 4-pin Euro-style quick-disconnect fitting Operating Conditions Temperature: − 40 °C to +70 °C ( − 40 °F to +158 °F) 90% at +50 °C maximum relative humidity (non-condensing) Vibration and Mechanical Shock All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 Hz to 60 Hz, max., double amplitude 0.06 inch acceleration 10G). Method 213B conditions H&I. Shock: 75G with unit operating; 100G for non- operation Certifications Q40 Sensors: dc-Voltage Series 4 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 121516 Rev. A

40.1 mm(1.58") 50.0 mm(1.97") 46.0 mm(1.81") 20.1 mm(0.79") (Jam Nut Supplied) Lens Centerline 19.8 mm(0.78") M30 x 1.5 Thread 2 m (6.5') Cable QD Models 50.0 mm(1.97") (Jam Nut Supplied) 19.8 mm(0.78") M30 x 1.5 Thread 82.5 mm(3.25") Green LED Power Indicator Amber LED Output Indicator All measurements are listed in millimeters [inches], unless noted otherwise. Performance Curves Opposed Mode Excess Gain 100 1000 EXCESS GAIN DISTANCE Q40 Series Opposed Mode Beam Pattern 0250 mm500 mm750 mm 250 mm500 mm750 mm 010"20"30" 10"20"30" DISTANCE Q40 SeriesOpposed Mode Polarized Retroreflective Performance based on use of a model BRT-3 retroreflector (3" diameter). Actual sensing range may be more or less than specified, depending on the efficiency and reflective area of the retroreflector used. Excess Gain 100 1000 EXCESS GAIN DISTANCE Q40 Series Polarized Retro with BRT-3 Reflector Beam Pattern 050 mm100 mm150 mm 50 mm100 mm150 mm 02"4"6" 2"4"6" DISTANCE Q40 SeriesPolarized Retro with BRT-3 Reflector Q40 Sensors: dc-Voltage Series P/N 121516 Rev. A www.bannerengineering.com - Tel: +1-763-544-3164 5

Performance based on use of a 90% reflectance white test card.† Focus and spot sizes are typical. Fixed-Field—200 mm 100 EXCESS GAIN DISTANCE

1000 Q40 Series

Fixed-field modewith 200 mm farlimit cutoff Ø 16 mm spot size @ 35 mm focus Ø 20 mm spot size @ 200 mm cutoff † Using 18% gray test card: Cutoff distance will be 95% of value shown. † Using 6% black test card: Cutoff distance will be 90% of value shown. Fixed-Field—400 mm 100 EXCESS GAIN DISTANCE Fixed-field modewith 400 mm farlimit cutoff Ø 17 mm spot size @ 35 mm focus Ø 25 mm spot size @ 400 mm cutoff † Using 18% gray test card: Cutoff distance will be 90% of value shown. † Using 6% black test card: Cutoff distance will be 85% of value shown. Fixed-Field—600 mm Excess Gain 100 EXCESS GAIN DISTANCE Fixed-field modewith 600 mm farlimit cutoff Ø 17 mm spot size @ 35 mm focus Ø 30 mm spot size @ 600 mm cutoff † Using 18% gray test card: Cutoff distance will be 85% of value shown. † Using 6% black test card: Cutoff distance will be 75% of value shown. Quick-Disconnect (QD) Cables 4-Pin Threaded M12/Euro-Style Cordsets Model Length Style Dimensions Pinout (Female) MQDC-406 1.83 m (6 ft) Straight 44 Typ. ø 14.5 M12 x 1 1 = Brown 2 = White 3 = Blue 4 = Black MQDC-415 4.57 m (15 ft) MQDC-430 9.14 m (30 ft) MQDC-450 15.2 m (50 ft) MQDC-406RA 1.83 m (6 ft) Right-Angle 32 Typ.[1.26"] 30 Typ.[1.18"] ø 14.5 [0.57"] M12 x 1 MQDC-415RA 4.57 m (15 ft) MQDC-430RA 9.14 m (30 ft) MQDC-450RA 15.2 m (50 ft) Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. Q40 Sensors: dc-Voltage Series © Banner Engineering Corp. All rights reserved