Q2C-VMM-1000-01 TEC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 4

Technical content

Features

  • DIN 96 enclosur e
  • Pr ogrammable backlit LCD screen
  • V oltage IN-OUT connections
  • CT curr ent measurement 0.1A
  • Plug and sock et connections
  • Pr ogrammable VT, CT ratios
  • Modbus™ R TU as standard
  • 2 pulsed outputs with led indica tion
  • PF bar indica tor
  • 3P4W , 3P3W, 1P2W system types
  • Individual harmonics t o 63rd Benefits
  • C ost effective
  • Eas y installation
  • R J12 connection Approvals
  • IEC BS EN 6 1010-1:2010
  • BS EN 6 1326-1:2013
  • IEC 6205 3-21 Class 1
  • IEC 6205 3-24 Class 1

ENERGY /// CROMPTON-INSTRUMENTS.COM Displayed Parameters

  • V oltage per phase L-N, L-L
  • Current per phase and Max Demand
  • P ower Factor – per phase and system
  • T otal Harmonic Distortion – Voltage and Current per phase
  • Neutr al current
  • Fr equency system
  • Phase Sequenc e
  • A ctive Power (P) per phase, total and Max Demand
  • R eactive Power (Q) per phase, total and Max Demand
  • Appar ent Power (S) per phase, total and Max Demand
  • Ener gy – Active and Reactive Importing and Total
  • Ener gy – Active and Reactive Exporting and Total Product Codes Dimensions Wiring Diagrams Description Part number INTEGRA 1221 multifunction panel meter LCD Input 480V 100mA / 1A AC 2 pulsed outputs, Modbus RS485. RJ12 CT connectivity INT-1221-S-01 3-phase 4-wire 3-phase 3-wire 1-phase 2-wire Cutout Details

ENERGY /// CROMPTON-INSTRUMENTS.COM ParametersSpecifications Input Nominal input voltage 57.7 – 276V AC L-N (100-480V L-L) 576V L-L MAX Max. continuous input overload voltage 120% of nominal Max. short duration input voltage 2 x nominal voltage for 1 second Nominal input voltage burden < 0.2VA per phase Nominal input current 100mA Nom. Input current burden < 0.1 VA Max. continuous input overload current 120% of nominal Max. short duration input current 20 x nominal current for 1 second Auxiliary Operating range Self powered (from any of the three phases) Supply burden < 10 VA Accuracy Voltage (V) +/- 0.5% of range maximum Current (A) +/- 0.5% of range maximum Frequency (Hz) +/- 0.2% of mid-frequency Power factor (PF) +/- 1% of unity (0.01) Active power (W) +/- 1.0% of range maximum Reactive power (VAr) +/- 1.0% of range maximum Apparent power (VA) +/- 1.0% of range maximum Active energy (kWh) Class 1 IEC 62053-21 or Class 0.5 IEC 62053-22 Reactive energy (kVArh) Class 2 IEC 62053-23 THD 2% to 63rd harmonic Measured Range Voltage (V) 5 – 120% of nominal (Min 100V – self powered) Current (A) 5 – 120% of nominal Frequency (Hz) 44 – 66 Hz Power (W, VAr, VA) 5 – 144% of nominal (bi-directional) Energy 8 digit, upto 9999999.9 MWh Power factor 4 quadrant THD 0 – 40% upto 63rd harmonic Environment Operating temperature -25˚C to +55˚C Storage temperature -40˚C to +70˚C Relative humidity 0 to 95%, non-condensing Shock 30g in 3 planes Vibration 10Hz to 50Hz, IEC 60068-2-6, 2g Dielectric Voltage 4kV between voltage and current to earth Altitude 3000m Warm-up 1 minute Outputs Pulsed output relay (configurable) Opto-coupled, potential-free SPST-NO contact Contact Rating current 2-27mA at 27V DC Contact Rating voltage 5-27V DC Pulse Width 60/100/200 ms Pulse rate 0.001/0.01 /0.1/1/10/100/1000 kWh/kVArh Pulsed output relay (non-configurable) 3200IMP/kWh Communications Modbus RTU (RS485) Type 2-wire half duplex Baud rate 2400, 4800, 9600, 19200, 38400 Address 1 to 247 Enclosure Enclosure Style DIN 96 panel mount Dimensions 96x96x62 mm Panel cut-out 92x92mm Panel thickness 1-5 mm Protection rating Front IP54, Rear IP30 Material UL 94-VO Weight 340 g Cable size 0.05mm 2 – 2.5mm2 stranded wire Terminals Voltage and Current : Shrouded screw clamp Button Scr Parameter Watts L1 Volts L1 Current L1 Active Energy L1

2 Watts L2

1 L-N Volts L1, L2, L3

2 L-L Volts L1, L2, L3

3 Current L1, L2, L3, N

4 V-THD% per line

5 I-THD% per line

6 Phase Sequence V&I

1 PF and System Freq

2 PF per phase

3 MD per phase

4 System Max demand

P, Q, S.

1 Active Power (P)

L1, L2, L3

2 Reactive Power (Q)

L1, L2, L3

3 Apparent Power (S)

L1, L2, L3

4 System Powers P,Q,S

1 Imp Active Energy

2 Imp Reactive Energy

3 Total Active Energy

3-IN-1 CURRENT TRANSFORMERS The 3-in-1 current transformer range are for use with the INTEGRA 1221 digital metering system which combines three traditional current transformers in one moulding case with a RJ12 connection for simple and easy error free installation. ENERGY /// CROMPTON-INSTRUMENTS.COM Product Codes Primary Current VA at Class 1 VA at Class 0.5 DL3N1-35-60/0.1 60A 0.25 - DL3N1-35-125/0.1 125A 0.5 0.25 DL3N1-35-160/0.1 160A 0.35 0.25 DL3N1-35-250/0.1 250A 0.5 0.25 DL3N1-45-250/0.1 250A 0.25 - DL3N1-45-400/0.1 400A - 0.25 DL3N1-45-600/0.1 600A - 0.25 DL3N1-70-400/0.1 400A - 0.25 DL3N1-70-600/0.1 600A - 0.25 DL3N1-70-800/0.1 800A - 0.25 Voltage Meter to Meter Loom The meter to meter loom connects the voltage for upto 32 meters using high quality LSZH cable fitted with suitable plugs and socket for safe and easy voltage connections. Part Number Length Q2C-VMM-0600-01 600mm Q2C-VMM-1000-01 1000mm Q2C-VMM-1200-01 1200mm Q2C-VMM-1500-01 1500mm Q2C-VMM-2000-01 2000mm Other lengths available Part Number Length Q2C-VFO-0600-01 600mm Q2C-VFO-1000-01 1000mm Q2C-VFO-1200-01 1200mm Q2C-VFO-1500-01 1500mm Other lengths available Voltage Meter to Open Loom The meter to open loom connects the voltage supply from the fused connections to the meter using high quality LSZH cable fitted with suitable plugs and socket for safe and easy voltage connections. For email or phone, go to: crompton-instruments.com FOR MORE INFORMATION: TE Technical Support Centres UK +44 1376 509 401 USA: +1 800 327 6996 Australia +61 1300 656 090 Singapore +65 6590 5151 Hong Kong: +852 2738 8193 crompton-instruments.com © 2017 TE Connectivity Ltd. family of companies. All Rights Reserved. EPP-2881-11/17. TE, TE Connectivity, the TE connectivity (logo) and Integra are trademarks of the TE Connectivity Ltd. family of companies. Crompton Instruments is a trademark of Crompton Parkinson and is used under a licence. Other logos, product and company names mentioned herein may be trademarks of their respective owners. While TE has made every reasonable effort to ensure the accuracy of the information in this brochure, TE does not guarantee that it is error-free, nor does TE make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information contained herein at any time without notice. TE expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this brochure are for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE for the latest dimensions and design specifications. crompton-instruments.com