FR27UQ69V50T ETC | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
Semiconductor fusesSemiconductor (AC) fuses SCAC194 Other Protistor® Fuses Ferrule Fuses 27x60 URQ/URS/URB - 690 V to 1000 VAC Watts loss 0,8 IN IN * Minimum operating voltage for trip-indicator: 20 V Fuseholder Solution: See Gears and Fuse gears section Voltage rating UN(VAC) 690 V Class Current rating IN (A) 100 125 160 200 250 125 160 100 125 160 170 Tested Breaking capacity 200 kA @ 690 V 200 kA @ 690 V 100 kA @ 1000 V Total clearing I2t I2tt (A2s) 610 @ 660 V 860 @ 660 V 1880 @ 660 V 3210 @ 660 V 6970 @ 660 V 15000 @ 660 V 30000 @ 660 V 63000 @ 660 V 13000 @ 660 V 24000 @ 660 V 250 @ 1000 V 450 @ 1000 V 840 @ 1000 V 1470 @ 1000 V 3300 @ 1000 V 6000 @ 1000 V 12500 @ 1000 V 26700 @ 1000 V 36000 @ 1000 V Pre-arcing I2t @ 1 ms I2tp (A2s) 110 155 350 625 1400 3150 6580 15570 2790 5500 110 200 435 975 1910 3890 4710 URQ URB1000 V 8.4 11.1 12.6 14.2 15.7 17.7 19.4 22.6 14.5 17.5 7.4 8.7 9.7 11.3 12.3 14.5 EXTREMELY HIGH IBREAKING CAPACITY FUSES: PROTECTION OF POWER SEMI CONDUCTORS ACCORDING TO IEC STANDARD 60269.1 AND 4
690 V - 1000 V AC VOLTAGE RATING
aR-CLASS ACCORDING TO VDE 636-23 AND IEC 60269.4 690V URQ and 1000V URB are UL RECOGNIZED Main Characteristics URS690 V
Semiconductor fusesSemiconductor (AC) fuses Other Protistor® Fuses Ferrule Fuses 27x60 URQ/URS/URB - 690 V to 1000 VAC URQ 27x60 - With trip-indicatior 50 A 63 A 80 A 100 A 125 A 160 A 200 A 250 A 125 A 160 A 32 A 40 A 50 A 63 A 80 A 100 A 125 A 160 A 170 A N075958 V076309 W076310 R078330 S078331 X076311 T078332 T076308 P209865 Q209866 S081298 R081297 Q081296 P081295 N081294 M081293 L081292 K081291 Z080338
6.921 CP URQ 27x60/ 50
6.921 CP URQ 27x60/ 63
6.921 CP URQ 27x60/ 80
6.921 CP URQ 27x60/100
6.921 CP URQ 27x60/125
6.921 CP URQ 27x60/160
6.921 CP URQ 27x60/200
6.921 CP URQ 27x60/250
6.921 CP URS 27x60/125
6.921 CP URS 27x60/160
1021 CP URB 27x60/ 32
1021 CP URB 27x60/ 40
1021 CP URB 27x60/ 50
1021 CP URB 27x60/ 63
1021 CP URB 27x60/ 80
1021 CP URB 27x60/100
1021 CP URB 27x60/125
1021 CP URB 27x60/160
1021 CP URB 27x60/170
Type Designation Catalog NumberRef. Number 690 V 1000 V 60,3 Ø 27 Ø 5 Except 125 and 160A URS URS 690 V 60,3 Ø 5 Ø 27 FR27UQ69V50T FR27UQ69V63T FR27UQ69V80T FR27UQ69V100T FR27UQ69V125T FR27UQ69V160T FR27UQ69V200T FR27UQ69V250T FR27US69V125T FR27US69V160T FR27UB10C32T FR27UB10C40T FR27UB10C50T FR27UB10C63T FR27UB10C80T FR27UB10C100T FR27UB10C125T FR27UB10C160T FR27UB10C170T
Semiconductor fusesSemiconductor (AC) fuses SCAC196 Other Protistor® Fuses Ferrule Fuses 27x60 URQ/URS/URB - 690 V to 1000 VAC Time vs current characteristics Tolerance for mean pre-arcing current ± 8%. a = 130 B1 = 1,25 A2 = 0,6 B2 = 0,6 Cf3 = 0,8 a = 130 B1 = 1,25 A2 = 0,6 B2 = 0,6 Cf3 = 0,8 I (A) t (s) URS 125A 160A
Semiconductor fusesSemiconductor (AC) fuses Other Protistor® Fuses Ferrule Fuses 27x60 URQ/URS/URB - 690 V to 1000 VAC Corrective factor Peak arc voltage Above: Mean curves show variation of total clearing time ( I2tt) and total clearing duration tt as a function of operating voltage U. Left: Curves indicate permissible value of time constant L/r as a function of the DC working voltage These curves show peak value Um of arc voltage which appears across the fuse-link as a function of operating voltage U @ cos ϕ = 0.15. 50 to 200 A URQ 250 A URQ 32 to170 A URB 50 to 200 A URQ 250 A URQ 32 to170 A URB K K K 1,2 0,8 0,6 0,4 0 200 400 600 1,2 0,8 0,6 0,4 0,20,2 0 200100 400 300500 600 U(V) U(V) 1,2 0,8 0,6 0,4 0,2 0 200 400 600 800 1000 U(V) L R 100 200 300 400 500 600 U(V) (ms) In <= 160 A In <= 200 A In <= 250 A 200 300 400 500 600 700 800 500 700 900 1100 1300 1500 U (V) Um (V) 125-160A URS 125-160A URS Um(V) U(V) 2000 1000 0 100 200 300 400 500 600 700 Um(V) U(V) 2000 1000 100 200 300 400 500 500600 600700 700 800 900 1000 Um(V) 2000 1000 U(V)