Datasheet sections

  • 1 Product Description
  • 1.1 Models
  • 1.2 Overview
  • 1.3 Banner Radar Configuration Software
  • 1.4 Features and Indicators
  • 2 Installation Instructions
  • 2.1 Sensor Orientation
  • 2.2 Mount the Device
  • 2.3 Wiring
  • 2.4 Install the Software
  • 3 Getting Started
  • 3.1 Connect to the Sensor
  • 3.2 Software Overview
  • 4 Banner Radar Configuration Workspace
  • 4.1 Navigation Toolbar
  • 4.2 Live Sensor Data and Legend
  • 4.3 Summary Pane
  • 4.4 Sensor Settings Pane
  • 4.5 Live Sensor Data Controls
  • 5 Remote Input
  • 5.1 Teach Output 1 Switch Point
  • 5.2 Remote Setup
  • 5.3 Set the Sensitivity
  • 6 Reset the Sensor to Factory Defaults
  • 6.1 Factory Default Settings
  • 7 Specifications
  • 7.1 FCC Part 15 and CAN ICES-3 (B)/NMB-3(B)
  • 7.2 PC Requirements
  • 7.3 Beam Patterns
  • 7.4 Dimensions
  • 8 Windows
  • 9 Update the Software
  • 10 Accessories
  • 10.1 Configuration Tool
  • 10.2 Quick Disconnect (QD) Cordsets
  • 10.3 Brackets and Enclosures
  • 11 Product Support and Maintenance
  • 11.1 Repairs
  • 11.2 Contact Us

R-GAGE® Q130RA Sensor Instruction Manual Original Instructions 208831 Rev. B

15 May 2019

© Banner Engineering Corp. All rights reserved 208831

1 Product Description

Radar-Based Sensors for Detection of Moving and Stationary Targets  FMCW radar detects moving and stationary objects  Adjustable sensing field—ignores objects beyond setpoint  Easy setup and configuration of range, sensitivity, and output using the Banner Radar Configuration Software and Pro Converter Cable  Sensing functions are unaffected by wind, falling rain or snow, fog, humidity, air temperatures, or light  Sensor operates in Industrial, Scientific, and Medical (ISM) telecommunication band  Rugged IP67 housing withstands harsh environments WARNING:  Do not use this device for personnel protection  Using this device for personnel protection could result in serious injury or death.  This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A device failure or malfunction can cause either an energized (on) or de-energized (off) output condition.

1.1 Models

Beam Angle Telecom Approval1 Output Connection2 Q130RA-9076-AFQ 24 m (78.7 ft) 90° × 76° Telecom approved for US, UK, Europe, China, Australia, and New Zealand Bipolar NPN/PNP N.O./N.C. Configurable Integral 5-pin Euro-style (M12) quick-disconnect (QD) Q130RA-2450-AFQ 40 m (131.2 ft) 24° × 50°

1.2 Overview

The R-GAGE sensor emits a well-defined beam of high-frequency radio waves from an internal antenna. Some of this emitted energy reflects back to the receiving antenna. Signal processing electronics in the sensor determine the distance from the sensor to the object based on the time delay of the return signal. The sensor can be configured (using a PC or remote input wire) to sense objects up to a specific distance, ignoring objects beyond this distance (also called background suppression). 1 For additional countries, contact Banner Engineering. 2 Models with a quick disconnect require a mating cordset. See Quick Disconnect (QD) Cordsets on page 23. R-GAGE® Q130RA Sensor www.bannerengineering.com - Tel: + 1 888 373 6767 3

*The specific detection range depends on the radar cross section and returned signal strength of the specific target. Figure 1. Sensing Range

1.3 Banner Radar Configuration Software

Use the Banner Radar Configuration software and Pro Converter Cable to set up the R-GAGE sensor. For more information visit www.bannerengineering.com/us/en/products/sensors/software/radar-configuration.html.

1.4 Features and Indicators

Figure 2. R-GAGE Features

1 Power Green Power ON

2 Signal

3 Output 1 Amber Output energized

4 Output 2 Amber Output energized

point, the Signal Strength indicator is on and does not flash.

Description

Signal Strength Output 1/2 Off Normally Open = Off Normally Closed = On There is no detectable object within the switch point distance that is returning a signal greater than the minimum signal strength threshold of one. Flashing Normally Open = Off Normally Closed = On An object is detected, however, the output is off because the returned signal strength is below the user-defined threshold. The flash rate increases as the signal strength increases. Flashing Normally Open = On Normally Closed = Off A target is detected and the returned signal strength is stronger than the user-defined threshold. The flash rate increases as the signal strength increases. On Normally Open = On Normally Closed = Off A target is detected and the signal is four times stronger than the user- defined signal strength threshold. R-GAGE® Q130RA Sensor www.bannerengineering.com - Tel: + 1 888 373 6767 5

2 Installation Instructions

2.1 Sensor Orientation

Correct sensor-to-object orientation is important to ensure proper sensing. Minimize the tilt angle of a target relative to the sensor. The target should be titled less than half of the beam angle. Figure 3. Tilt angle of the target relative to the sensor

2.2 Mount the Device

  1. If a bracket is needed, mount the device onto the bracket.
  2. Mount the device (or the device and the bracket) to the machine or equipment at the desired location. Do not tighten

the mounting screws at this time.

  1. Check the device alignment.

This is done via the red Signal Strength LED or the Banner Radar Configuration Software.

  1. Tighten the mounting screws to secure the device (or the device and the bracket) in the aligned position.

2.3 Wiring

ground or dc common. Shielded cordsets are recommended for all quick-disconnect models.

2.4 Install the Software

Important: Administrative rights are required to install the Banner Radar Configuration software.

  1. Download the latest version of the software from www.bannerengineering.com/us/en/products/sensors/software/ radar-configuration.html. 2. Navigate to and open the downloaded file. 3. Click Install to begin the installation process. 4. Depending on your system settings, a popup window may appear prompting to allow Banner Radar Configuration to make changes to your computer. Click Yes. 5. Click Close to exit the installer. R-GAGE® Q130RA Sensor www.bannerengineering.com - Tel: + 1 888 373 6767 7

3 Getting Started

Power up the sensor, and verify that the power LED is ON green.

3.1 Connect to the Sensor

  1. Connect the sensor to the Pro Converter Cable.
  2. Connect the Pro Converter Cable to the PC.
  3. Open the Banner Radar Configuration Software.

Sensor > Connect on the Navigation toolbar. The Connection screen displays.

  1. Select the correct Sensor Model and Com Port for the sensor.

A message displays confirming the connection to the sensor. The Connection screen closes and the sensor data displays.

3.2 Software Overview

Figure 4. Banner Radar Configuration Software

  1. Navigation toolbar—Use this toolbar to connect to the sensor, to save or load a configuration, or to reset to factory
  2. Live Sensor Data and Legend—Shows the signal strength versus distance for the connected sensor, as well as
  3. Summary pane—Displays the distance to the target, the signal strength, and the output status
  4. Sensor Settings pane—Set the sensor parameters in this pane
  5. Status bar—Shows whether the sensor is connected, if a software update is available, and if the sensor data is
  6. Live Sensor Data controls—Use these controls to record, freeze, and play real-time sensor data

4 Banner Radar Configuration Workspace

4.1 Navigation Toolbar

Use this toolbar to connect to the sensor, to save or load a configuration, or to reset to factory defaults. From the File menu, the following options are available: Load Config Load a configuration to the connected sensor. Use this option to set up multiple sensors with the same parameters. Save Config Save a configuration to a desired location for future use. Note: Click Stop in the Live Sensor Data controls to enable Save Config. (Click Play to resume live data sampling.) Exit Exit the Banner Radar Configuration Software. From the Sensor menu, the following options are available: Connect Connect to the sensor. Disconnect Disconnect from the sensor. Factory Reset Select to perform a factor reset on the sensor. All custom parameters will be lost. From the Help menu, the following option is available: About Select to view the software version number, the copyright notice, and the warranty.

4.2 Live Sensor Data and Legend

The Live Sensor Data area displays the live distance and amplitude signal from the connected radar sensor. The signal strength threshold, switch point, and hysteresis are also plotted. Use these signals to evaluate targets to determine where the signal strength threshold and switch point should be configured for reliable detection. Use the Y-Axis Max and the X-Axis Max to adjust the range displayed on the plot. Click Update to apply changes. Legend Use the legend to select which data appears on the graph. Signal Displays the strength of the signal over distance. Primary Targets Represents the signal strength and location of the strongest target inside the switch point. Signal Threshold Displays the signal strength threshold. Switch Point Displays the switch point distance. Hysteresis Displays the hysteresis distance. R-GAGE® Q130RA Sensor www.bannerengineering.com - Tel: + 1 888 373 6767 9

4.3 Summary Pane

The Summary pane (blue shaded area) displays Distance, Signal Strength, and Output Status. Displays the distance to the target. minimum detection threshold (Signal Strength Threshold = 1). Displays whether the output is ON or OFF.

4.4 Sensor Settings Pane

Set parameters for the sensor. highlight on a parameter's value indicates changes that have not yet been written to the sensor. Output 1 tab on the Sensor Settings pane. Select the desired output filtering from the list. This parameter controls the base response time of the sensor. target of sufficient signal strength causes the sensor's output to change. output turns on and off. Hysteresis is intended to prevent the output from chattering. Figure 5. How hysteresis affects the sensor output target that is required to change the output state. NO/NC: Select Normally Open or Normally Closed from the list.

4.5 Live Sensor Data Controls

After connecting to the sensor, data sampling begins automatically (but not recording). To stop data sampling, click Stop. This is required to load/save a configuration. To restart data sampling, click Play. This only samples data from the sensor and displays it on the plot; it does not record the data to a log file. To record data to a log file, click Record. The log file selection prompt displays. Save the log file as desired. The log file format is Common Data Format v3.7.0. R-GAGE® Q130RA Sensor www.bannerengineering.com - Tel: + 1 888 373 6767 11

5 Remote Input

Use the remote input to program the sensor remotely. the button on the cable. The Software cannot be sampling data while remote input is in use. 0.04 seconds ≤ T ≤ 0.8 seconds . Exit remote programming modes by setting the remote input Low for longer than 2 seconds or by waiting for 60 seconds. Figure 6. Remote Input Map

5.1 Teach Output 1 Switch Point

  1. Pulse the remote input once. The green power LED flashes slowly.
  2. Teach the Output 1 switch point.

Single-pulse the remote input. T The green power LED flashes, alternating with the amber Output LEDs. Teach Accepted The sensor flashes the green power LED three times, then exits remote teach and returns to run mode. Teach Not Accepted The green Power and red Signal Strength LEDs alternate flashing and the switch point automatically moves to the maximum range (the same range as the factory default).

5.2 Remote Setup

Use Remote Setup to set the output mode to either Switch Point Object Teach or Switch Point Background Teach and to set normally open or normally closed. Changing the Output 1 Mode using remote input affects both the output configuration (normally open versus normally closed) and the Teach mode. The output configuration change takes effect immediately and can be used to change the output between normally open and normally closed without changing the switch point distance. The change in Teach mode does not immediately change the switch point location, but will affect the behavior of the next remote Teach. Switch Point Object Teach sets the switch point 0.5 meters (1.6 feet) beyond the location of the target, farther away from the sensor's face. Use Switch Point Object Teach so that the sensor can reliably detect when a target is in the same position as when it was configured. Switch Point Background Teach sets the switch point 1 meter (3.3 feet) in front of the target, closer to the sensor's face. Use Switch Point Background Teach to reliably ignore the taught background and reliably detect an object that is present in front of the taught background. 1. Access Remote Setup. Action Result Double-pulse the remote input. T T T The green power LED flashes slowly. 2. Single pulse the remote input to enter Output 1 mode. 3. Select the desired output mode. Action Result Pulses Output Mode

1 T Switch Point Object Teach

(Normally Open) T T T Switch Point Object Teach (Normally Closed) T T T T T Switch Point Background Teach (Normally Open) T T T T T T T Switch Point Background Teach (Normally Closed) The green Power LED flashes three times, Normally Open/Normally Closed changes occur immediately, and the next and any subsequent remote teach are configured to be background or object (see Teach Output 1 Switch Point on page 12). The sensor exits remote teach and returns to run mode. R-GAGE® Q130RA Sensor www.bannerengineering.com - Tel: + 1 888 373 6767 13

5.3 Set the Sensitivity

Use Sensitivity Selection to set the signal strength threshold. 1. Access Sensitivity Selection. Action Result Triple-pulse the remote input. T T T T T The green power LED flashes slowly. 2. Select the desired signal threshold. Action Result Pulse s TEACH Mode

1 T Signal Strength Threshold = 1

T Signal Strength Threshold = 1.13 T T T T T Signal Strength Threshold = 1.25 T T T T T T T Signal Strength Threshold = 1.5 T T T T T T T T T Signal Strength Threshold = 2 T T T T T T T T T T T Signal Strength Threshold = 5 T T T T T T T T T T T T T Signal Strength Threshold = 6.5 T T T T T T T T T T T T T T T Signal Strength Threshold = 7.5 The signal strength is set and the green power LED on the sensor flashes three times. The sensor exits remote teach and returns to run mode. R-GAGE® Q130RA Sensor 14 www.bannerengineering.com - Tel: + 1 888 373 6767

6 Reset the Sensor to Factory Defaults

Reset the sensor to factory default settings using one of two methods. Note: If a factory reset is performed through the Banner Radar Configuration Software, the remote input wire becomes disabled (factory default setting). If the sensor is returned to factory defaults by using the remote input wire, the input wire remains enabled and the rest of the settings are restored to factory defaults. Reset Using the Banner Radar Configuration Software Go to Sensor > Factory Reset. The sensor indicators flash once, the sensor is reset back to the factory default settings, and a confirmation message displays. Reset Using the Remote Input Eight-pulse the remote input to apply the factory defaults. T T T T T T T T T T T T T T T

6.1 Factory Default Settings

9076 models: 24 m 2450 models: 40 m N.O./N.C. Normally Open On Delay 0 ms Off Delay 0 ms Output filtering 50 ms-ON/500 ms-OFF Remote input Disabled Signal Strength Threshold 1.0 R-GAGE® Q130RA Sensor www.bannerengineering.com - Tel: + 1 888 373 6767 15

7 Specifications

The sensor is able to detect a proper object (see Detectable Objects) at the following ranges, depending on the target: 9076 models: 1 m to 24 m (3.3 ft to 78.7 ft) 2450 models: 1 m to 40 m (3.3 ft to 131.2 ft) Detectable Objects Objects containing metal, water, or similar high-dielectric materials Operating Principle Frequency modulated continuous-wave (FMCW) radar Operating Frequency 24.050-24.250 GHz, ISM Band Maximum Output Power ERP: 3.3 mW, 5 dBm EIRP: 100 mW, 20 dBm Supply Voltage (Vcc)

12 V dc to 30 V dc

Power and Current Consumption, exclusive of load Normal Run Mode: 1.2 W, Current consumption < 50 mA at 24 V dc Supply Protection Circuitry Protected against reverse polarity and transient overvoltages Delay at Power-up < 3 seconds Output Configuration Bipolar NPN/PNP output Load 1 on pin 2 (white wire) = NPN Load 2 on pin 4 (black wire) = PNP Output Ratings 50 mA maximum capability each output Saturation: < 3.5 V at 50 mA Off-state leakage current: Outputs specifications per configuration PNP Output High ≥ Vsupply - 2.5 V Output Low ≤ 2.5 V (loads ≤ 70 kΩ) NPN Output High ≥ Vsupply - 2.5 V (loads ≤ 70 kΩ) Output Low ≤ 2.5 V Output Protection Protected against short circuit conditions Response Time Software selectable: 50 ms ON/50 ms OFF 100 ms ON/100 ms OFF 50 ms ON/500 ms OFF 50 ms ON/1000 ms OFF Indicators Power LED: Green (power ON) Signal Strength LED: Red, flashes in proportion to signal strength. Steady on at 4x excess gain. Only indicates signal amplitude, not target distance. Output LEDs: Amber (output energized) See Figure 2 on page 4 Construction Housing: ABS/polycarbonate QD Connector: Stainless steel Mounting Threads: Stainless steel Vibration All models meet IEC 60947-5-2 (Vibration: 10 Hz to 55 Hz; 1 mm peak- to-peak amplitude; 5 minute duration; 30 minutes in each of the three axes at resonant frequency or at 55 Hz) Shock All models meet IEC 60947-5-2 (Shock: 30G peak acceleration, 11 ms pulse duration, half sine wave pulse shape) Operating Temperature Environmental Rating IEC IP67 Connections Integral 5-pin M12/Euro-style quick disconnect. Models with a quick disconnect require a mating cordset Certifications E224071 UL Environmental Rating: Type 1 ETSI/EN 300 440 FCC ID: UE3RGAGE1XX for others, contact Banner Engineering Country of Origin: USA

7.1 FCC Part 15 and CAN ICES-3 (B)/NMB-3(B)

This device complies with part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the manufacturer. R-GAGE® Q130RA Sensor 16 www.bannerengineering.com - Tel: + 1 888 373 6767

7.2 PC Requirements

Microsoft® Windows® operating system version 103 Hard Drive Space 130MB Third-Party Software .NET version 4.6.2 or higher USB Port Available USB port Important: Administrative rights are required to install the Banner Radar Configuration software.

7.3 Beam Patterns

Note: The effective beam pattern depends on the signal strength threshold and the properties of the target.

7.3 Model -2450

Typical Beam Pattern (with BRTR-CC20E Radar Target, Radar Cross Section = 50 m2) Typical Beam Pattern (with 4 different targets) with Signal Strength Threshold = 1 Left-Right Beam Pattern -10 m 10 m 20 m -20 m 10 m 20 m 30 m 40 m0 50 m a b c d e f g h Left-Right Beam Pattern -10 m 10 m 20 m Target 1 Target 4 -20 m 10 m 20 m 30 m 40 m 50 m0 3 Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and/or other countries. R-GAGE® Q130RA Sensor www.bannerengineering.com - Tel: + 1 888 373 6767 17

Typical Beam Pattern (with BRTR-CC20E Radar Target, Radar Cross Section = 50 m2) Typical Beam Pattern (with 4 different targets) with Signal Strength Threshold = 1 Up-Down Beam Pattern 20 m 10 m 0 m 10 m 20 m 0 10 m 20 m 30 m 40 m 50 m a b c d e f g h Distance Beam Pattern Signal Strength Threshold a 7.50 b 6.50 c 5.00 d 2.00 e 1.50 f 1.25 g 1.13 h 1.00 Up-Down Beam Pattern -10 m 10 m 20 m Target 1 Target 4 -20 m 10 m 20 m 30 m 40 m 50 m0 Distance 1: Weak Object (Radar cross section = 0.25 m2) 2: Car (Radar cross section = 3 m2) 3: Large Truck (Radar cross section = 50 m2) 4: Passenger Train (Radar cross section = 300 m2) R-GAGE® Q130RA Sensor 18 www.bannerengineering.com - Tel: + 1 888 373 6767

7.3 Model -9076

Typical Beam Pattern (with BRTR-CC20E Radar Target, Radar Cross Section = 50 m2) Typical Beam Pattern (with 4 different targets) with Signal Strength Threshold = 1 Left-Right Beam Pattern 20 m 10 m 0 m 10 m 20 m 0 10 m 20 m 30 m 40 m b c d a Distance Beam Pattern Signal Strength Threshold a 4.50 b 1.75 c 1.25 d 1.00 Left-Right Beam Pattern 20 m 10 m 0 m 10 m 20 m 0 10 m 20 m 30 m 40 m Target 4 Target 1 Distance 1: Weak Object (Radar cross section = 0.25 m2) 2: Car (Radar cross section = 3 m2) 3: Large Truck (Radar cross section = 50 m2) 4: Passenger Train (Radar cross section = 300 m2) R-GAGE® Q130RA Sensor www.bannerengineering.com - Tel: + 1 888 373 6767 19

7.4 Dimensions

All measurements are listed in millimeters [inches], unless noted otherwise. R-GAGE® Q130RA Sensor 20 www.bannerengineering.com - Tel: + 1 888 373 6767

8 Windows

The R-GAGE sensor can be placed behind a glass or a plastic window, but the configuration must be tested and the distance from the sensor to the window must be determined and controlled prior to installation. There is typically a 20% signal reduction when the sensor is placed behind a window. Polycarbonate at 4 mm thickness performs well in most situations, but the performance depends on filler materials. Thinner (1 to 3 mm) windows have high reflection. The amount of reflection depends on the material, thickness, and distance from the sensor to the window. Locate the sensor in a position of minimum reflection from the window, which will repeat every 6.1 mm of distance between the sensor and the window. The positions of maximum reflection from the window repeat between the minimums, and decrease in effect until the window is approximately 150 mm (5.9 in) away. Consult the factory for pre-tested window materials which can be used at any distance without issue. Additionally, the face of the window should be protected from flowing water and ice by use of a flow diverter or hood directly above the window. Falling rain or snow in the air in front of the window, light water mist, or small beads on the face of the window are typically not an issue. However, a thick, continuous surface of water or ice directly on the face of the window can be detected as a dielectric boundary. R-GAGE® Q130RA Sensor www.bannerengineering.com - Tel: + 1 888 373 6767 21

9 Update the Software

Use this procedure to update the Banner Radar Configuration Software. right corner indicates that a software update is available. Figure 7. Software Update Available

  1. Click ! in the lower right corner of the software.

The Banner Radar Configuration Software Update screen displays. Figure 8. Banner Radar Configuration Software Update Screen

  1. Click Upgrade to begin the process.

to the sensor, then return to step 1, above, to update the Software.

  1. Navigate to and open the file BannerRadarConfigInstaller.exe.
  2. Depending on your system settings, a popup window may appear prompting to allow Banner Radar Configuration

Software to make changes to your computer. Click Yes.

  1. Click Close to exit the installer.

The software update is complete.

10 Accessories

10.1 Configuration Tool

 Pro Converter Cable  1.83 m (6 ft) M12/Euro-style quick disconnect to Device and USB to PC  Required for connection to Pro Editor

10.2 Quick Disconnect (QD) Cordsets

5-Pin Threaded M12/Euro-Style Cordsets—with Shield Model Length Style Dimensions Pinout (Female) MQDEC2-506 1.83 m (6 ft) Straight 44 Typ. ø 14.5 M12 x 1 2 1 = Brown 2 = White 3 = Blue 4 = Black 5 = Gray MQDEC2-515 4.57 m (15 ft) MQDEC2-530 9.14 m (30 ft) MQDEC2-550 15.2 m (50 ft) MQDEC2-506RA 1.83 m (6 ft) Right-Angle 32 Typ. [1.26"] 30 Typ. [1.18"] ø 14.5 [0.57"] M12 x 1 MQDEC2-515RA 4.57 m (15 ft) MQDEC2-530RA 9.14 m (30 ft) MQDEC2-550RA 15.2 m (50 ft)

10.3 Brackets and Enclosures

 Sensor mounting plate and pivoting bracket  Provides ± 20° of tilt in one axis for enhanced sensor alignment  12 gauge stainless steel  Sensor can mount on bracket horizontally or vertically SMBQ240SS2  Add-on accessory to be used in conjunction with SMBQ240SS1  Provides ± 20° of tilt in second axis for maximum control of sensor alignment  12 gauge stainless steel R-GAGE® Q130RA Sensor www.bannerengineering.com - Tel: + 1 888 373 6767 23

 Rear-Mount Protective Metal Enclosure  Supports both horizontal and vertical sensor mounting  Required if the R-GAGE is exposed to rain or snow  Prevents buildup of water or ice from interfering with sensor performance R-GAGE® Q130RA Sensor 24 www.bannerengineering.com - Tel: + 1 888 373 6767

11 Product Support and Maintenance

11.1 Repairs

Contact Banner Engineering for troubleshooting of this device. Do not attempt any repairs to this Banner device; it contains no field-replaceable parts or components. If the device, device part, or device component is determined to be defective by a Banner Applications Engineer, they will advise you of Banner's RMA (Return Merchandise Authorization) procedure. Important: If instructed to return the device, pack it with care. Damage that occurs in return shipping is not covered by warranty. You may be asked to provide the configuration file and the data log file (.cdf) to aid in troubleshooting.

11.2 Contact Us

Banner Engineering Corporate headquarters is located at:

9714 Tenth Avenue North

Minneapolis, MN 55441, USA Website: www.bannerengineering.com Phone: + 1 888 373 6767 For worldwide locations and local representatives, visit www.bannerengineering.com. 11.3 Banner Engineering Corp. Software Copyright Notice This software is protected by copyright, trade secret, and other intellectual property laws. You are only granted the right to use the software and only for the purposes described by Banner. Banner reserves all other rights in this software. For so long as you have obtained an authorized copy of this software directly from Banner, Banner grants you a limited, nonexclusive, nontransferable right and license to use this software. You agree not to use, nor permit any third party to use, this software or content in a manner that violates any applicable law, regulation or terms of use under this Agreement. You agree that you will not reproduce, modify, copy, deconstruct, sell, trade or resell this software or make it available to any file-sharing or application hosting service. Disclaimer of Warranties. Your use of this software is entirely at your own risk, except as described in this agreement. This software is provided "AS-IS." To the maximum extent permitted by applicable law, Banner, it affiliates, and its channel partners disclaim all warranties, expressed or implied, including any warranty that the software is fit for a particular purpose, title, merchantability, data loss, non-interference with or non-infringement of any intellectual property rights, or the accuracy, reliability, quality or content in or linked to the services. Banner and its affiliates and channel partners do not warrant that the services are secure, free from bugs, viruses, interruption, errors, theft or destruction. If the exclusions for implied warranties do not apply to you, any implied warranties are limited to 60 days from the date of first use of this software. Limitation of Liability and Indemnity. Banner, its affiliates and channel partners are not liable for indirect, special, incidental, punitive or consequential damages, damages relating to corruption, security, loss or theft of data, viruses, spyware, loss of business, revenue, profits, or investment, or use of software or hardware that does not meet Banner minimum systems requirements. The above limitations apply even if Banner and its affiliates and channel partners have been advised of the possibility of such damages. This Agreement sets forth the entire liability of Banner, its affiliates and your exclusive remedy with respect to the software use. You agree to indemnify and hold Banner and its affiliates and channel partners harmless from any and all claims, liability and expenses, including reasonable attorney's fees and costs, arising out of your use of the Services or breach of this Agreement (collectively referred to as "Claims"). Banner reserves the right at its sole discretion and at its own expense, to assume the exclusive defense and control of any Claims. You agree to reasonably cooperate as requested by Banner in defense of any Claims. 11.4 Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. R-GAGE® Q130RA Sensor www.bannerengineering.com - Tel: + 1 888 373 6767 25

D delay off 10 on 10 distance 10 H hysteresis 10 N NC 10 NO 10 normally closed 10 normally open 10 O off delay 10 on delay 10 output filtering 10 output LED 4 output status 10 P PC requirements 17 power LED 4 R range X 9 Y 9 S signal strength 10 signal strength LED 4 software 4, 22 T total response time 10 X X range 9 Y Y range 9 Z zone 10