Part number: 15608 Data sheet Feature Value Type code PZV Design Mechanical sequence counter with pneumatic actuator Reset method Manual key or pneumatic signal Display 5-digit Actuator drop-off pressure 0.2 ± 0.1 bar Resetting cutout pressure 0.15 ± 0.1 bar Actuator response pressure 0.6 ± 0.2 bar Operating pressure 2 bar ... 8 bar Minimum resetting pressure 2 bar Min. pulse length for actuator 10 ms Min. pulse length for reset 180 ms Minimum pause period for actuator 15 ms Minimum pause period for reset 50 ms Explosion prevention and protection Zone 1 (ATEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 22 (ATEX) Operating medium Compressed air as per ISO 8573-1:2010 [7:4:4] Information on operating and pilot media Operation with oil lubrication not possible Ambient temperature 0 °C ... 60 °C Product weight 150 g Type of mounting Front panel mounting Pneumatic connection M5 4/30/21 - Subject to change - Festo AG & Co. KG 1/1