PXIE-AI5100 National-Instruments-Corporation
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 45
Technical content
Expandable PXI bundle based on PXIe-4309 Nanovolt Meter, 32 Ch, 28 Bit, 2MS/s Specifications PXIe-1083 and PXIe-4309
This document combines the PDFs of this bundle together. The page numbers in the table of contents correspond to the page number of PDF the component’s documentation begins. Test Workflow P/N: 788509-35 Test Workflow is a bundle of select NI software featuring engineering-specific tools that help test professionals accomplish anything from their day-to-day work to overcoming their most challenging obstacles. Test Workflow includes:
- LabVIEW - a graphical programming environment engineers use to develop automated research, validation, and production test systems.
- InstrumentStudio- an application software that provides an integrated approach to interactive PXI measurements.
- TestStand- a test executive software that accelerates system development and deployment for engineers in validation and production.
- And more NI Software! PXIe-4309 Analog Input PXIe-1083 (5-Slot PXIe Chassis) Accessories:
- TB-4309 Front-mounted
- Terminal Block
- Thunderbolt cable
- Power cable (varied by PN) o 867125-01 (US) o 867125-02 (EUR) o 867125-03 (Generic)
This document contains specifications for the PXIe-1083 chassis. Electrical The following section provides information about the PXIe-1083 AC input and DC output. AC Input Input rating 100 VAC to 240 VAC, 50 Hz/60 Hz, 6 A to 3 A Operating voltage range1 90 VAC to 264 VAC Nominal input frequency 50 Hz/60 Hz Operating frequency range1 47 Hz to 63 Hz Efficiency 78% typical Over-current protection Internal fuse in line Main power disconnect The AC power cable provides main power disconnect. Do not position the equipment so that it is difficult to disconnect the power cord. The front-panel power switch causes the internal chassis power supply to provide DC power to the PXI Express backplane. Caution Disconnect power cord to completely remove power. © National Instruments 3 PXIe-1083 Specifications
DC output characteristics of the PXIe-1083. Maximum total available power for the PXIe-1083 is 293 W. The maximum combined power available on +3.3 V and +5 V is 180 W. The maximum power available for each Thunderbolt port is 15 W (5 V/3 A). Table 1. Backplane Slot Current Capacity Note PCI V(I/O) pins in Hybrid Peripheral Slots are connected to +5 V. temperature considerations at 58 W.
Module cooling Forced air circulation (positive pressurization) through one 150 CFM fan Module slot airflow direction Bottom of module to top of module Module intake Bottom of chassis Module exhaust Top, right side of chassis Slot cooling capacity 58 W; slot 6 supports 58 W cooling with high fan mode Power supply cooling Forced air circulation through integrated fans Power supply intake Front and left side chassis Power supply exhaust Rear of chassis Minimum chassis cooling clearances Above 44.45 mm (1.75 in.) Rear 44.45 mm (1.75 in.) Sides 44.45 mm (1.75 in.) Below Rack 44.45 mm (1.75 in.) Desktop 25.4 mm (1.00 in.) © National Instruments 5 PXIe-1083 Specifications
Maximum altitude 2,000 m (6,560 ft.), 800 mbar (at 25 °C ambient, high fan mode) Pollution Degree 2 Indoor use only. Operating Environment Ambient temperature range When all peripheral modules require ≤38 W cooling capacity per slot 0 °C to 50 °C (IEC 60068-2-1 and IEC 60068-2-2.)2 Meets MIL-PRF-28800F Class 3 low temperature limit and high temperature limit. When any peripheral module requires >38 W cooling capacity per slot 0 °C to 40 °C (IEC 60068-2-1 and IEC 60068-2-2.)2 Meets MIL-PRF-28800F Class 3 low temperature limit and MIL- PRF-28800F Class 4 high temperature limit. Relative humidity range 20% to 80%, noncondensing Storage Environment Ambient temperature range –40 °C to 71 °C (IEC-60068-2-1 and IEC-60068-2-2.)[3] Meets MIL- PRF-28800F Class 3 limits. Relative humidity range 10% to 95%, noncondensing ni.com6 PXIe-1083 Specifications
Operational shock 30 g peak, half-sine, 11 ms pulse (IEC-60068-2-27.)3 Meets MIL- PRF-28800F Class 2 limits. Operational random vibration 5 to 500 Hz, 0.3 grms Non-operating vibration 5 to 500 Hz, 2.4 grms (IEC 60068-2-64.)3 Non-operating test profile exceeds the requirements of MIL-PRF-28800F, Class 3. Acoustic Emissions Sound Pressure Level (at Operator Position) (Tested in accordance with ISO 7779. Meets MIL-PRF-28800F requirements.)
38 W Profile
Auto fan (up to 30 °C ambient) 33.7 dBA High fan 50.8 dBA
58 W Profile
Auto fan (up to 30 °C ambient) 54.7 dBA High fan 55.3 dBA Sound Power Level © National Instruments 7 PXIe-1083 Specifications
Auto fan (up to 30 °C ambient) 44.9 dBA High fan 60.3 dBA Auto fan (up to 30 °C ambient) 63.4 dBA High fan 64.2 dBA Note The protection provided by the PXIe-1083 can be impaired if it is used in a manner not described in this document. Safety Compliance Standards This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use: ■ IEC 61010-1, EN 61010-1 ■ UL 61010-1, CSA C22.2 No. 61010-1 Note For safety certifications, refer to the product label or the Product Certifications and Declarations section. EMC Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment. ni.com8 PXIe-1083 Specifications
This product is intended for use in industrial locations. However, harmful interference may occur in some installations, when the product is connected to a peripheral device or test object, or if the product is used in residential areas. To minimize interference with radio and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. Furthermore, any changes or modifications to the product not expressly approved by NI could void your authority to operate it under your local regulatory rules. EMC Notices Refer to the following notices for cables, accessories, and prevention measures necessary to ensure the specified EMC performance. Notice For EMC declarations and certifications, and additional information, refer to the Product Certifications and Declarations section. Notice Changes or modifications to the product not expressly approved by NI could void your authority to operate the product under your local regulatory rules. Notice Operate this product only with shielded cables and accessories. Electromagnetic Compatibility Standards This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: ■ EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity ■ EN 55011 (CISPR 11): Group 1, Class A emissions © National Instruments 9 PXIe-1083 Specifications
■ AS/NZS CISPR 11: Group 1, Class A emissions Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes. Note In Europe, Canada, Australia, and New Zealand (per CISPR 11) Class A equipment is intended for use in nonresidential locations. CE Compliance This product meets the essential requirements of applicable European Directives, as follows: ■ 2014/35/EU; Low-Voltage Directive (safety) ■ 2014/30/EU; Electromagnetic Compatibility Directive (EMC) ■ 2011/65/EU; Restriction of Hazardous Substances (RoHS) Product Certifications and Declarations Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link. Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the Engineering a Healthy Planet web page at ni.com/environment. This page contains the environmental ni.com10 PXIe-1083 Specifications
regulations and directives with which NI complies, as well as other environmental information not included in this document. EU and UK Customers
- Waste Electrical and Electronic Equipment (WEEE)—At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/ environment/weee. 电子信息产品污染控制管理办法(中国 RoHS)
- 5 40e 中国 RoHS— NI 符合中国电子信息产品中限制使用某些有害物 质指令(RoHS)。关于 NI 中国 RoHS 合规性信息,请登录 ni.com/environment/ rohs_china。(For information about China RoHS compliance, go to ni.com/ environment/rohs_china.) Backplane Size 3U-sized; 5 peripheral slots. Compliant with IEEE 1101.10 mechanical packaging. PXI Express Specification compliant. Accepts both PXI Express and CompactPCI (PICMG 2.0 R 3.0) 3U modules. Backplane bare-board material UL 94 V-0 Recognized Backplane connectors Conforms to IEC 917 and IEC 1076-4-101, UL 94 V-0 rated System Synchronization Clocks
10 MHz System Reference Clock: PXI_CLK10
© National Instruments 11 PXIe-1083 Specifications
Maximum slot-to-slot skew 250 ps Accuracy ±25 ppm max (guaranteed over the operating temperature range) Maximum jitter 5 ps RMS phase-jitter (10 Hz–1 MHz range) Duty-factor 45% to 55% Unloaded signal swing 3.3 V ±0.3 V Note For other specifications, refer to the PXI-1 Hardware Specification.
100 MHz System Reference Clock: PXIe_CLK100 and PXIe_SYNC100
Maximum slot-to-slot skew 100 ps Accuracy ±25 ppm max (guaranteed over the operating temperature range) Maximum jitter 3 ps RMS phase-jitter (10 Hz to 12 kHz range), 2 ps RMS phase-jitter (12 kHz to 20 MHz range) Duty-factor for PXIe_CLK100 45% to 55% Absolute differential voltage (When terminated with a 50 Ω load to 1.30 V or Thévenin equivalent) 400 mV to 1000 mV Note For other specifications, refer to the PXI-5 PXI Express Hardware Specification. ni.com12 PXIe-1083 Specifications
for installing the optional rack mount kits. Figure 1. PXIe-1083 Chassis Dimensions (Front)
Figure 2. PXIe-1083 Chassis Dimensions (Side) Figure 3. PXIe-1083 Chassis Dimensions (Bottom) 1 The operating range is guaranteed by design.
2 This product meets the requirements of the environmental standards for electrical
equipment for measurement, control, and laboratory use.
3 This product meets the requirements of the environmental standards for electrical
equipment for measurement, control, and laboratory use. © 2022 National Instruments Corporation.
32 Ch (8 ADC), 2 MS/s, 18 - 28 bit, Flexible Resolution PXI Analog Input
This document lists specifications for the PXIe-4309 data acquisition module. All specifications are subject to change without notice. Refer to ni.com/manuals for the most current specifications and product documentation. Note To maintain forced air cooling in the PXIe system, refer to the Maintain Forced-Air Cooling Note to Users. T erminology Maximum and minimum specifications characterize the warranted performance of the instrument within the recommended calibration interval and under the stated operating conditions. These specifications are subject to production verification or guaranteed by design. Typical specifications are specifications met by the majority of the instruments within the recommended calibration interval and under the stated operating conditions, based on measurements taken during production verification and/or engineering development. The performance of the instrument is not warranted. Supplemental specifications describe the basic function and attributes of the instrument established by design and are not subject to production verification. They provide information that is relevant for the adequate use of the instrument that is not included in the previous definitions. The following specifications are typical at 25 °C, unless otherwise noted.
- Textcal is the device temperature at last external calibration.
- Tselfcal is the device temperature at last self-calibration.
17 | ni.com | PXIe-4309 Specifications Input Characteristics Number of channels Measurement resolution Maximum sample rate3, 4 Auto zero none Auto zero once Auto zero every sample Chopping Maximum working voltage 1 Up to 4 channels per ADC. 2 Depends on the sample rate. Refer to the Noise versus Sampling Rate section for more information. 3 For multichannel, up to 4 channels per ADC.
4 Refer to the PXIe-4309 User Manual for Maximum Sample Rates in Hardware-Timed Single Point,
On-Demand, and External Sample Clock modes.
PXIe-4309 Specifications | © National Instruments | 18 Input impedance Device on, channel idle Device on, channel active Input bias current Overvoltage protection Overvoltage protection input current programmed I/O
Table 1. DC Voltage Specifications for Auto Zero None
24 Hour†, ‡
2 Year
†Relative to External Calibration Source. included in the Absolute Accuracy values over the stated self-calibration temperature intervals. Table 2. DC Voltage Performance Specifications for Auto Zero None
10 S/s 10 kS/s 2 MS/s
specifications table for Sample Rate ≤10 S/s.
Table 3. DC Voltage Specifications for Auto Zero Once †Relative to External Calibration Source. included in the Absolute Accuracy values over the stated self-calibration temperature intervals. Table 4. DC Voltage Performance Specifications for Auto Zero Once specifications table for Sample Rate ≤10 S/s.
Table 5. DC Voltage Specifications for Auto Zero Every Sample †Relative to External Calibration Source. included in the Absolute Accuracy values over the stated self-calibration temperature intervals. Table 6. DC Voltage Performance Specification for Auto Zero Every Sample
10 S/s 10 kS/s
specifications table for Sample Rate ≤10 S/s.
Table 7. DC Voltage Specifications for Chopping †Relative to External Calibration Source. included in the Absolute Accuracy values over the stated self-calibration temperature intervals. Table 8. DC Voltage Performance Specifications for Chopping specifications table for Sample Rate ≤10 S/s.
Figure 1. Auto Zero Every Sample Offset Cancellation Stability
Figure 2. Chopping Offset Cancellation Stability
Figure 3. Offset Cancellation Spectral Noise Density
Figure 10. Digital Filter Frequency Response 1 Applies to sampling rates ≤ 1 MS/s for all configurations that use a single channel per ADC. 2 Applies to sampling rates ≤ 200 kS/s (aggregate) for all configurations that use multiple channels per ADC. 3 Does not apply to Hardware-Timed Single Point, On-Demand, and External Sample Clock modes.
Figure 11. 2 MS/s Spectral Noise Density (Single channel per ADC)
Figure 20. Common-Mode Rejection Ratio 1 To maintain crosstalk performance use separation and/or shielding between signal cables. 2 Inputs shorted at terminal block screw terminals. 3 Inputs shorted at SCB-68 screw terminals using 2 m, 68-pin cable.
PXIe-4309 Specifications | © National Instruments | 38 Onboard Calibration Reference Voltage Frequency Timebase Characteristics Accuracy Timing and Synchronization Digital Triggers PXIe_DStar A, PXIe_DStar B Output Timing Signals sample clock
39 | ni.com | PXIe-4309 Specifications PFI 0 and PFI 1 (Front Panel Digital Triggers) Input Output Low, VOL General Specifications Bus Interface specification rev 1.0 compliant Power Requirements
PXIe-4309 Specifications | © National Instruments | 40 Physical 3U CompactPCI slot Caution Do not use the PXIe-4309 for connections to signals or for measurements within Categories II, III, or IV . Caution The protection provided by the PXIe-4309 can be impaired if it is used in a manner not described in this document. Caution Clean the hardware with a soft, nonmetallic brush. Make sure that the hardware is completely dry and free from contaminants before returning it to service. Environmental Specifications Operating Environment (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2. Meets MIL-PRF-28800F Class 3 low temperature limit and MIL-PRF-28800F Class 2 high temperature limit.) (Tested in accordance with IEC 60068-2-56.) Indoor use only. 1 Measurement Categories CAT I and CAT O are equivalent. These test and measurement circuits are not intended for direct connections to the MAINS building installations of Measurement Categories CAT II, CAT III, CAT IV .
41 | ni.com | PXIe-4309 Specifications Storage Environment (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2. Meets MIL-PRF-28800F Class 3 limits.) (Tested in accordance with IEC 60068-2-56.) Shock and Vibration (Tested in accordance with IEC 60068-2-27. Meets MIL-PRF-28800F Class 2 limits.) Random vibration rms (Tested in accordance with IEC 60068-2-64. Non-operating test profile exceeds the requirements of MIL-PRF-28800F, Class 3.) Calibration You can obtain the calibration certificate and information about calibration services for the PXIe-4309 at ni.com/calibration. gain, offset, and linearity corrections relative to the high-precision internal voltage reference. self-calibration is recommended whenever the current device temperature differs by more than the specified temperature range from the device temperature at which the last self-calibration was performed.
PXIe-4309 Specifications | © National Instruments | 42 Safety This product meets the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use:
- IEC 61010-1, EN 61010-1
- UL 61010-1, CSA 61010-1 Note For UL and other safety certifications, refer to the product label or the Online Product Certification section. Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:
- EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
- EN 55011 (CISPR 11): Group 1, Class A emissions
- EN 55022 (CISPR 22): Class A emissions
- EN 55024 (CISPR 24): Immunity
- AS/NZS CISPR 11: Group 1, Class A emissions
- AS/NZS CISPR 22: Class A emissions
- FCC 47 CFR Part 15B: Class A emissions
- ICES-001: Class A emissions Note In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, and heavy-industrial locations. In Europe, Canada, Australia and New Zealand (per CISPR 11) Class A equipment is intended for use only in heavy-industrial locations. Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes. Note For EMC declarations and certifications, and additional information, refer to the Online Product Certification section. Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes. Note For EMC declarations and certifications, and additional information, refer to the Online Product Certification section.
43 | ni.com | PXIe-4309 Specifications CE Compliance This product meets the essential requirements of applicable European Directives as follows:
- 2014/35/EU; Low-V oltage Directive (safety)
- 2014/30/EU; Electrom agnetic Compatibility Directive (EMC) Online Product Certification Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for this product, visit ni.com/ certification, search by model number or product line, and click the appropriate link in the Certification column. Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the Minimize Our Environmental Impact web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of the product life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers, National Instruments WEEE initiatives, and compliance with WEEE Directive 2002/96/EC on Waste and Electronic Equipment, visit ni.com/environment/ weee. ⊩ ˄ЁRoHS˅ Ёᅶ᠋ National InstrumentsՓ⫼ᶤѯ᳝ᆇ⠽䋼ᣛҸ (RoHS)Ѣ National Instruments ЁRoHSᙃˈ䇋ⱏᔩ ni.com/ environment/rohs_chinaDŽ(For information about China RoHS compliance, go to ni.com/environment/rohs_china.)
© 2017 National Instruments. All rights reserved. 377030A-01 May17 Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for more information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patents Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. Worldwide Support and Services The NI website is your complete resource for technical support. At ni.com/support you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. Visit ni.com/services for NI Factory Installation Services, repairs, extended warranty, and other services. Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI. A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European Communities using the manufacturer’s declaration of conformity. This system affords the user protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC for your product by visiting ni.com/certification. If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration. NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI also has offices located around the world. For telephone support in the United States, create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the Worldwide Offices section of ni.com/niglobal to access the branch office websites, which provide up-to-date contact information, support phone numbers, email addresses, and current events.