PXIE-DMM5101 NI | Alldatasheet

Document overview

  • PDF pages: 35

Technical content

Expandable PXI bundle based on PXIe-4080 Digital Multimeter, 6 1/2-Digit, 300V, 1A Specifications PXIe-1083 and PXIe-4080

This document combines the PDFs of this bundle together. The page numbers in the table of contents correspond to the page number of PDF the component’s documentation begins. Test Workflow P/N: 788509-35 Test Workflow is a bundle of select NI software featuring engineering-specific tools that help test professionals accomplish anything from their day-to-day work to overcoming their most challenging obstacles. Test Workflow includes:

  • LabVIEW - a graphical programming environment engineers use to develop automated research, validation, and production test systems.
  • InstrumentStudio- an application software that provides an integrated approach to interactive PXI measurements.
  • TestStand- a test executive software that accelerates system development and deployment for engineers in validation and production.
  • And more NI Software! PXIe-4080 Digital Multimeter PXIe-1083 (5-Slot PXIe Chassis) Accessories:
  • Thunderbolt cable
  • Power cable (varied by PN) o 867115-01 (US) o 867115-02 (EUR) o 867115-03 (Generic)

This document contains specifications for the PXIe-1083 chassis. Electrical The following section provides information about the PXIe-1083 AC input and DC output. AC Input Input rating 100 VAC to 240 VAC, 50 Hz/60 Hz, 6 A to 3 A Operating voltage range1 90 VAC to 264 VAC Nominal input frequency 50 Hz/60 Hz Operating frequency range1 47 Hz to 63 Hz Efficiency 78% typical Over-current protection Internal fuse in line Main power disconnect The AC power cable provides main power disconnect. Do not position the equipment so that it is difficult to disconnect the power cord. The front-panel power switch causes the internal chassis power supply to provide DC power to the PXI Express backplane. Caution Disconnect power cord to completely remove power. © National Instruments 3 PXIe-1083 Specifications

DC output characteristics of the PXIe-1083. Maximum total available power for the PXIe-1083 is 293 W. The maximum combined power available on +3.3 V and +5 V is 180 W. The maximum power available for each Thunderbolt port is 15 W (5 V/3 A). Table 1. Backplane Slot Current Capacity Note PCI V(I/O) pins in Hybrid Peripheral Slots are connected to +5 V. temperature considerations at 58 W.

Module cooling Forced air circulation (positive pressurization) through one 150 CFM fan Module slot airflow direction Bottom of module to top of module Module intake Bottom of chassis Module exhaust Top, right side of chassis Slot cooling capacity 58 W; slot 6 supports 58 W cooling with high fan mode Power supply cooling Forced air circulation through integrated fans Power supply intake Front and left side chassis Power supply exhaust Rear of chassis Minimum chassis cooling clearances Above 44.45 mm (1.75 in.) Rear 44.45 mm (1.75 in.) Sides 44.45 mm (1.75 in.) Below Rack 44.45 mm (1.75 in.) Desktop 25.4 mm (1.00 in.) © National Instruments 5 PXIe-1083 Specifications

Maximum altitude 2,000 m (6,560 ft.), 800 mbar (at 25 °C ambient, high fan mode) Pollution Degree 2 Indoor use only. Operating Environment Ambient temperature range When all peripheral modules require ≤38 W cooling capacity per slot 0 °C to 50 °C (IEC 60068-2-1 and IEC 60068-2-2.)2 Meets MIL-PRF-28800F Class 3 low temperature limit and high temperature limit. When any peripheral module requires >38 W cooling capacity per slot 0 °C to 40 °C (IEC 60068-2-1 and IEC 60068-2-2.)2 Meets MIL-PRF-28800F Class 3 low temperature limit and MIL- PRF-28800F Class 4 high temperature limit. Relative humidity range 20% to 80%, noncondensing Storage Environment Ambient temperature range –40 °C to 71 °C (IEC-60068-2-1 and IEC-60068-2-2.)[3] Meets MIL- PRF-28800F Class 3 limits. Relative humidity range 10% to 95%, noncondensing ni.com6 PXIe-1083 Specifications

Operational shock 30 g peak, half-sine, 11 ms pulse (IEC-60068-2-27.)3 Meets MIL- PRF-28800F Class 2 limits. Operational random vibration 5 to 500 Hz, 0.3 grms Non-operating vibration 5 to 500 Hz, 2.4 grms (IEC 60068-2-64.)3 Non-operating test profile exceeds the requirements of MIL-PRF-28800F, Class 3. Acoustic Emissions Sound Pressure Level (at Operator Position) (Tested in accordance with ISO 7779. Meets MIL-PRF-28800F requirements.)

38 W Profile

Auto fan (up to 30 °C ambient) 33.7 dBA High fan 50.8 dBA

58 W Profile

Auto fan (up to 30 °C ambient) 54.7 dBA High fan 55.3 dBA Sound Power Level © National Instruments 7 PXIe-1083 Specifications

Auto fan (up to 30 °C ambient) 44.9 dBA High fan 60.3 dBA Auto fan (up to 30 °C ambient) 63.4 dBA High fan 64.2 dBA Note The protection provided by the PXIe-1083 can be impaired if it is used in a manner not described in this document. Safety Compliance Standards This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use: ■ IEC 61010-1, EN 61010-1 ■ UL 61010-1, CSA C22.2 No. 61010-1 Note For safety certifications, refer to the product label or the Product Certifications and Declarations section. EMC Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment. ni.com8 PXIe-1083 Specifications

This product is intended for use in industrial locations. However, harmful interference may occur in some installations, when the product is connected to a peripheral device or test object, or if the product is used in residential areas. To minimize interference with radio and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. Furthermore, any changes or modifications to the product not expressly approved by NI could void your authority to operate it under your local regulatory rules. EMC Notices Refer to the following notices for cables, accessories, and prevention measures necessary to ensure the specified EMC performance. Notice For EMC declarations and certifications, and additional information, refer to the Product Certifications and Declarations section. Notice Changes or modifications to the product not expressly approved by NI could void your authority to operate the product under your local regulatory rules. Notice Operate this product only with shielded cables and accessories. Electromagnetic Compatibility Standards This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: ■ EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity ■ EN 55011 (CISPR 11): Group 1, Class A emissions © National Instruments 9 PXIe-1083 Specifications

■ AS/NZS CISPR 11: Group 1, Class A emissions Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes. Note In Europe, Canada, Australia, and New Zealand (per CISPR 11) Class A equipment is intended for use in nonresidential locations. CE Compliance This product meets the essential requirements of applicable European Directives, as follows: ■ 2014/35/EU; Low-Voltage Directive (safety) ■ 2014/30/EU; Electromagnetic Compatibility Directive (EMC) ■ 2011/65/EU; Restriction of Hazardous Substances (RoHS) Product Certifications and Declarations Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link. Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the Engineering a Healthy Planet web page at ni.com/environment. This page contains the environmental ni.com10 PXIe-1083 Specifications

regulations and directives with which NI complies, as well as other environmental information not included in this document. EU and UK Customers

  • Waste Electrical and Electronic Equipment (WEEE)—At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/ environment/weee. 电子信息产品污染控制管理办法(中国 RoHS)
  • 5 40e 中国 RoHS— NI 符合中国电子信息产品中限制使用某些有害物 质指令(RoHS)。关于 NI 中国 RoHS 合规性信息,请登录 ni.com/environment/ rohs_china。(For information about China RoHS compliance, go to ni.com/ environment/rohs_china.) Backplane Size 3U-sized; 5 peripheral slots. Compliant with IEEE 1101.10 mechanical packaging. PXI Express Specification compliant. Accepts both PXI Express and CompactPCI (PICMG 2.0 R 3.0) 3U modules. Backplane bare-board material UL 94 V-0 Recognized Backplane connectors Conforms to IEC 917 and IEC 1076-4-101, UL 94 V-0 rated System Synchronization Clocks

10 MHz System Reference Clock: PXI_CLK10

© National Instruments 11 PXIe-1083 Specifications

Maximum slot-to-slot skew 250 ps Accuracy ±25 ppm max (guaranteed over the operating temperature range) Maximum jitter 5 ps RMS phase-jitter (10 Hz–1 MHz range) Duty-factor 45% to 55% Unloaded signal swing 3.3 V ±0.3 V Note For other specifications, refer to the PXI-1 Hardware Specification.

100 MHz System Reference Clock: PXIe_CLK100 and PXIe_SYNC100

Maximum slot-to-slot skew 100 ps Accuracy ±25 ppm max (guaranteed over the operating temperature range) Maximum jitter 3 ps RMS phase-jitter (10 Hz to 12 kHz range), 2 ps RMS phase-jitter (12 kHz to 20 MHz range) Duty-factor for PXIe_CLK100 45% to 55% Absolute differential voltage (When terminated with a 50 Ω load to 1.30 V or Thévenin equivalent) 400 mV to 1000 mV Note For other specifications, refer to the PXI-5 PXI Express Hardware Specification. ni.com12 PXIe-1083 Specifications

for installing the optional rack mount kits. Figure 1. PXIe-1083 Chassis Dimensions (Front)

Figure 2. PXIe-1083 Chassis Dimensions (Side) Figure 3. PXIe-1083 Chassis Dimensions (Bottom) 1 The operating range is guaranteed by design.

2 This product meets the requirements of the environmental standards for electrical

equipment for measurement, control, and laboratory use.

3 This product meets the requirements of the environmental standards for electrical

equipment for measurement, control, and laboratory use. © 2022 National Instruments Corporation.

ations apply to the PXIe-4080. Definitions Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty. The following characteristic specifications describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty. ■ Typical specifications describe the performance met by a majority of models. ■ Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing. Textcal is the device temperature at last external calibration. Tselfcal is the device temperature at last self-calibration. Conditions Specifications are valid under the following conditions unless otherwise noted. Refer to each section for additional conditions that apply. ■ Self-calibration performed within the last 24 hours ■ Calibration interval of 2 years ■ 60 minutes warm-up time © National Instruments 16 PXIe-4080 Specific ations

90 Day

2 Year Tself cal

Table 1. DC Voltage ± (ppm of reading + ppm of range)

e 1. DC Voltage Noise, Typical 10 n 100 n 1 μ 10 μ 100 μ 1 m 10 m 100 m Measurement Noise, RMS (Volts) Aperture Time (Seconds) 100 n 1 μ 10 μ 100 μ 1 m 10 m 100 m 100 mV 1 V 10 V 100 V 300 V Note With input short ed, Normal DC Noise Rejection, and Auto Zero ON. For apertures less than 100 ms, add five times the typical rms noise to the accuracy specification. General ADC Linearity 0.5 ppm of reading + 1 ppm of range Effective Common-Mode R ejection Ratio (CMRR) (1 kΩ resistance in LO lead) >140 dB (DC), 100 ms aperture; >170 dB (>46 Hz) with high-or der DC noise rejection, 100 ms aperture, typical Overrange 105% of range except 300 V DC voltage input bias current <30 pA at 23 °C, typical © National Instruments 18 PXIe-4080 Specific ations

24 Hr[5]

2 Year

1 MΩ 10 µA 10 V 20 + 2 90 + 10 95 + 10 5 + 1 2 + 1

10 MΩ 1 µA 10 V 100 + 2 800 + 10 800 + 10 20 + 3 20 + 3

100 MΩ[7] 1 µA || 10

10 V 500 + 10 3000 + 10 3000 + 10 300 + 10 300 + 10

Table 2. Resistance (4-Wire and 2-Wire

e 2. PXIe-4080 Resistance Noise, Typical 100 μ 1 m 10 m 100 m 100 1 k 100 k 10 k Measurement Noise, RMS (Ω) Aperture Time (Seconds) 100 Ω Range 1 kΩ Range 10 kΩ Range 100 kΩ Range

1 MΩ Range

≥10 MΩ Range 100 n 1 μ 10 μ 100 μ 1 m 10 m 100 m Note With input short ed, Normal DC Noise Rejection, and Auto Zero ON. For apertures less than 100 ms, add five times the typical rms noise to the accuracy specification. General Maximum 4-wire lead resistance Use the lesser of 10% of range or 1 kΩ DC Current Specifications Ac curacy All DC current accuracy specifications apply for apertures ≥100 ms, with Auto Zero and ADC calibration enabled. © National Instruments 20 PXIe-4080 Specific ations

1 A <800 mV 20 + 15 700 + 50 8 + 2

Table 3. DC Current ± (ppm of reading + ppm of range) Note With input open, Normal DC Noise R ejection, and Auto Zero ON. Overrange 105% of range except 1 A range.

1 Hz to

40 Hz[9]

50 V ±105 V

300 V ±450 V

Table 4. AC Voltage Accuracy ± (% of reading + % of range), 2 Years, Te

Table 5. AC Current Specifications ± (% of reading + % of range), 2 Years, Full operating Accuracy Add 20 ppm of reading to 10 VDC voltage specifications.

Frequency and Period Specifications No te Aperture time set to 150 ms. Frequency range 15 Hz to 500 kHz Period measurement range 2 µs to 66.67 ms AC Input V oltage Range Corresponding Isolat ed Digitizer Range Minimum Peak-to- P eak Signal Amplitude[14] Maximum P eak-to-Peak Signal Amplitude Accuracy 50 mV 100 mV 5 mV 200 mV Refer to the PXIe_CLK100 ac curacy of the chassis.500 mV 1 V 50 mV 2 V

5 V 10 V 500 mV 20 V

50 V 100 V 5 V 200 V

300 V 300 V 50 V 450 V

Temperature Specifications All t emperature accuracy specifications apply to apertures ≥100 ms, Auto Zero, and ADC calibration enabled. Use lowest possible resistance or voltage range for each temperature. Add probe accuracy and cold junction accuracy where applicable. Sensor Type Temperature Range Accuracy RTD[15] -200 to 600 °C 0.1 °C Thermistor[16] -80 to 150 °C 0.08 °C J Thermocouple -210 to 1200 °C 0.2 °C K Thermocouple -200 to 1200 °C 0.3 °C N Thermocouple -200 to 1300 °C 0.4 °C T Thermocouple -200 to 400 °C 0.3 °C E Thermocouple -200 to 1000 °C 0.2 °C © National Instruments 24 PXIe-4080 Specific ations

1 V 125 + 75 40 kHz 240 kHz

10 V 125 + 75 40 kHz 240 kHz

100 V 1 MΩ ± 2% 125 + 75 30 kHz 240 kHz

300 V 125 + 75 30 kHz 240 kHz

Table 6. Voltage Mode

Figure 4. PXIe-4080 Voltage Waveform Noise, Typical

1 V Range

10 V Range

100 V Range

300 V Range

1 A <800 mV 700 + 75 60 kHz 300 kHz

Table 7. Current Mode

Figure 5. PXIe-4080 Current Waveform Noise, Typical

1 A Range

measurements within Measurement Categories III or IV.

300 VDC or ACrms

Maximum common-mode voltage 300 VDC or ACrms Maximum voltage to earth ground HI 300 VDC or ACrms LO 300 VDC or ACrms HI SENSE 300 VDC or ACrms LO SENSE 300 VDC or ACrms Fuse When this fuse symbol is mark ed on a device, take proper precautions. Hazardous Voltage This icon denotes a warning advising you to take precautions to avoid electrical shock. Timing Mode Trigger Latency Maximum Reading R ate[19]AC Voltage All Functions Except AC V oltage[20] Voltage, current, and r esistance 15 µs <0 µs 20 kS/s Voltage and current digitizer 1.8 MS/s Power Power consumption <9 W from PXI Express backplane © National Instruments 28 PXIe-4080 Specific ations

+12 V load 0.55 A max + 3.3 V load 0.55 A max Physical Characteristics Dimensions 3U, one-slot, PXI/cPCI module; 2.0 cm x 13.0 cm x 21.6 cm Weight 340 g (12 oz), nominal Note If y ou need to clean the device, wipe it with a dry towel. Environment Maximum altitude 2,000 m (800 mbar) (at 25 °C ambient temperature) Pollution Degree 2 Indoor use only. Oper ating Environment Ambient temperature r ange 0 °C to 55 °C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2. Mee ts MIL-PRF-28800F Class 3 low temperature limit and MIL-PRF-28800F Class 2 high temperature limit.) Relative humidity range 10% to 90%, noncondensing (Tested in accordance with IEC 60068-2-56.) 29 ni.com PXIe-4080 Specific ations

r ange -40 °C to 71 °C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2. Mee ts MIL-PRF-28800F Class 3 limits.) Relative humidity range 5% to 95%, noncondensing (Tested in accordance with IEC 60068-2-56.) Shock and Vibration Operating shock 30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC 60068-2-27. Mee ts MIL-PRF-28800F Class 2 limits.) Random vibration Operating 5 Hz to 500 Hz, 0.3 grms (T ested in accordance with IEC 60068-2-64.) Nonoperating 5 Hz to 500 Hz, 2.4 grms (T ested in accordance with IEC 60068-2-64. Test profile exceeds the requirements of MIL-PRF-28800F, Class 3.) Compliance and Certifications Caution Elec tromagnetic interference can adversely affect the measurement accuracy of this product. The input terminals of this device are not protected for electromagnetic interference. As a result, this device may experience reduced measurement accuracy or other temporary performance degradation when connected cables are routed in an environment with radiated or conducted radio frequency electromagnetic interference. To limit radiated emissions and to ensure that this device functions within specifications in its operational electromagnetic environment, take precautions when designing, selecting, and installing measurement probes and cables. © National Instruments 30 PXIe-4080 Specific ations

Safety Compliance Standards This pr oduct is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use: ■ IEC 61010-1, EN 61010-1 ■ UL 61010-1, CSA C22.2 No. 61010-1 Note For UL and other safety certifications, refer to the product label or the Product Certifications and Declarations sec tion. Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: ■ EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity ■ EN 55011 (CISPR 11): Group 1, Class A emissions ■ EN 55022 (CISPR 22): Class A emissions ■ EN 55024 (CISPR 24): Immunity ■ AS/NZS CISPR 11: Group 1, Class A emissions ■ AS/NZS CISPR 22: Class A emissions ■ FCC 47 CFR Part 15B: Class A emissions ■ ICES-001: Class A emissions Note In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, and heavy-industrial locations. In Europe, Canada, Australia, and New Zealand (per CISPR 11), Class A equipment is intended for use only in heavy-industrial locations. Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes. 31 ni.com PXIe-4080 Specific ations

Note F or EMC declarations, certifications, and additional information, refer to the Online Product Certification sec tion. CE Compliance This product meets the essential requirements of applicable European Directives, as f ollows: ■ 2014/35/EU; Low-Voltage Directive (safety) ■ 2014/30/EU; Electromagnetic Compatibility Directive (EMC) Product Certifications and Declarations Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/certification, se arch by model number or product line, and click the appropriate link in the Certification column. Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the Minimize Our Environmental Impact web page at ni.com/environment. This p age contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more © National Instruments 32 PXIe-4080 Specific ations

information about how to recycle NI products in your region, visit ni.com/ environment/weee. 电子信息产品污染控制管理办法(中国 R oHS) 中国客户 National Instruments 符合中国电子信息产品中限制使用某 些有害物质指令(RoHS)。关于National Instruments 中国 RoHS 合规性信 息,请登录 ni.com/environment/rohs_china。(For information about China RoHS compliance, go to ni.com/environment/rohs_china.)

1 In p arallel with 150 pF, typical

2 R elative to external calibration source. 3 P erform offset nulling or add 200 mΩ to reading. 4 -10% t o 0% tolerance, typical. 5 R elative to external calibration source. 6 P erform offset nulling or add 2 ppm of range to the specifications. 7 2-wir e resistance measurement only. Use tempco outside Textcal +/- 10 °C. Typical accuracy is 5% between 105 MΩ and 1.05 GΩ. 8 R elative to external calibration source. 9 Applies t o DC coupled only.

10 Applies t o signals >2 mV

11 Specific ation is typical above 5 kHz. 12 -10% t o 0% tolerance, typical. 13 Up t o 4.5 V measurement for 1 mA test current. 33 ni.com PXIe-4080 Specific ations

14 Squar e wave input. Minimum required peak-to-peak signal level is valid only for frequencies up to the -3 dB bandwidth. For higher frequencies, the signal amplitude must be increased. Refer to the Digitizer Voltage Mode for bandwidths. 15 Based on Pt3851 R TD in a 4-wire configuration. 16 Based on 44004, 44006, and 44007 int erchangeable thermistors. 17 Input impedanc e in parallel with 150 pF, typical. When AC coupled, only 1 MΩ available. 18 T ypical AC coupled frequency is 6 Hz (±0.1 dB) and 0.8 Hz (-3 dB).

19 Maximum R eading Rate assumes minimum aperture time, Auto Zero is OFF, Offset

Compensated Ohms is OFF, ADC Calibration is OFF, Number of Averages is 1, and Settle Time is 0 seconds. Varying these settings will vary the reading rate.

20 T rigger latency for all functions except AC Voltage assumes Auto Zero, Offset

Compensated Ohms, and ADC Calibration are OFF. © National Instruments 34 PXIe-4080 Specific ations © 2022 National Instruments Corporation.