Expandable PXI bundle based on PXIe-6363 MIO DAQ, 32 AI Ch, 48 DIO Ch, 4 AO Ch Specifications PXIe-1083 and PXIe-6363
This document combines the PDFs of this bundle together. The page numbers in the table of contents correspond to the page number of PDF the component’s documentation begins. Test Workflow P/N: 788509-35 Test Workflow is a bundle of select NI software featuring engineering-specific tools that help test professionals accomplish anything from their day-to-day work to overcoming their most challenging obstacles. Test Workflow includes:
- LabVIEW - a graphical programming environment engineers use to develop automated research, validation, and production test systems.
- InstrumentStudio- an application software that provides an integrated approach to interactive PXI measurements.
- TestStand- a test executive software that accelerates system development and deployment for engineers in validation and production.
- And more NI Software! PXIe-6363 (Multifunction IO) PXIe-1083 (5-Slot PXIe Chassis) Accessories:
- SHC68-68-EPM Shielded Cable (x2)
- SCB-68A Connector Block (x2)
- Thunderbolt cable
- Power cable (varied by PN) o 867124-01 (US) o 867124-02 (EUR) o 867124-03 (Generic)
This document contains specifications for the PXIe-1083 chassis. Electrical The following section provides information about the PXIe-1083 AC input and DC output. AC Input Input rating 100 VAC to 240 VAC, 50 Hz/60 Hz, 6 A to 3 A Operating voltage range1 90 VAC to 264 VAC Nominal input frequency 50 Hz/60 Hz Operating frequency range1 47 Hz to 63 Hz Efficiency 78% typical Over-current protection Internal fuse in line Main power disconnect The AC power cable provides main power disconnect. Do not position the equipment so that it is difficult to disconnect the power cord. The front-panel power switch causes the internal chassis power supply to provide DC power to the PXI Express backplane. Caution Disconnect power cord to completely remove power. © National Instruments 3 PXIe-1083 Specifications
DC output characteristics of the PXIe-1083. Maximum total available power for the PXIe-1083 is 293 W. The maximum combined power available on +3.3 V and +5 V is 180 W. The maximum power available for each Thunderbolt port is 15 W (5 V/3 A). Table 1. Backplane Slot Current Capacity Note PCI V(I/O) pins in Hybrid Peripheral Slots are connected to +5 V. temperature considerations at 58 W.
Module cooling Forced air circulation (positive pressurization) through one 150 CFM fan Module slot airflow direction Bottom of module to top of module Module intake Bottom of chassis Module exhaust Top, right side of chassis Slot cooling capacity 58 W; slot 6 supports 58 W cooling with high fan mode Power supply cooling Forced air circulation through integrated fans Power supply intake Front and left side chassis Power supply exhaust Rear of chassis Minimum chassis cooling clearances Above 44.45 mm (1.75 in.) Rear 44.45 mm (1.75 in.) Sides 44.45 mm (1.75 in.) Below Rack 44.45 mm (1.75 in.) Desktop 25.4 mm (1.00 in.) © National Instruments 5 PXIe-1083 Specifications
Maximum altitude 2,000 m (6,560 ft.), 800 mbar (at 25 °C ambient, high fan mode) Pollution Degree 2 Indoor use only. Operating Environment Ambient temperature range When all peripheral modules require ≤38 W cooling capacity per slot 0 °C to 50 °C (IEC 60068-2-1 and IEC 60068-2-2.)2 Meets MIL-PRF-28800F Class 3 low temperature limit and high temperature limit. When any peripheral module requires >38 W cooling capacity per slot 0 °C to 40 °C (IEC 60068-2-1 and IEC 60068-2-2.)2 Meets MIL-PRF-28800F Class 3 low temperature limit and MIL- PRF-28800F Class 4 high temperature limit. Relative humidity range 20% to 80%, noncondensing Storage Environment Ambient temperature range –40 °C to 71 °C (IEC-60068-2-1 and IEC-60068-2-2.)[3] Meets MIL- PRF-28800F Class 3 limits. Relative humidity range 10% to 95%, noncondensing ni.com6 PXIe-1083 Specifications
Operational shock 30 g peak, half-sine, 11 ms pulse (IEC-60068-2-27.)3 Meets MIL- PRF-28800F Class 2 limits. Operational random vibration 5 to 500 Hz, 0.3 grms Non-operating vibration 5 to 500 Hz, 2.4 grms (IEC 60068-2-64.)3 Non-operating test profile exceeds the requirements of MIL-PRF-28800F, Class 3. Acoustic Emissions Sound Pressure Level (at Operator Position) (Tested in accordance with ISO 7779. Meets MIL-PRF-28800F requirements.)
38 W Profile
Auto fan (up to 30 °C ambient) 33.7 dBA High fan 50.8 dBA
58 W Profile
Auto fan (up to 30 °C ambient) 54.7 dBA High fan 55.3 dBA Sound Power Level © National Instruments 7 PXIe-1083 Specifications
Auto fan (up to 30 °C ambient) 44.9 dBA High fan 60.3 dBA Auto fan (up to 30 °C ambient) 63.4 dBA High fan 64.2 dBA Note The protection provided by the PXIe-1083 can be impaired if it is used in a manner not described in this document. Safety Compliance Standards This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use: ■ IEC 61010-1, EN 61010-1 ■ UL 61010-1, CSA C22.2 No. 61010-1 Note For safety certifications, refer to the product label or the Product Certifications and Declarations section. EMC Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment. ni.com8 PXIe-1083 Specifications
This product is intended for use in industrial locations. However, harmful interference may occur in some installations, when the product is connected to a peripheral device or test object, or if the product is used in residential areas. To minimize interference with radio and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. Furthermore, any changes or modifications to the product not expressly approved by NI could void your authority to operate it under your local regulatory rules. EMC Notices Refer to the following notices for cables, accessories, and prevention measures necessary to ensure the specified EMC performance. Notice For EMC declarations and certifications, and additional information, refer to the Product Certifications and Declarations section. Notice Changes or modifications to the product not expressly approved by NI could void your authority to operate the product under your local regulatory rules. Notice Operate this product only with shielded cables and accessories. Electromagnetic Compatibility Standards This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: ■ EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity ■ EN 55011 (CISPR 11): Group 1, Class A emissions © National Instruments 9 PXIe-1083 Specifications
■ AS/NZS CISPR 11: Group 1, Class A emissions Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes. Note In Europe, Canada, Australia, and New Zealand (per CISPR 11) Class A equipment is intended for use in nonresidential locations. CE Compliance This product meets the essential requirements of applicable European Directives, as follows: ■ 2014/35/EU; Low-Voltage Directive (safety) ■ 2014/30/EU; Electromagnetic Compatibility Directive (EMC) ■ 2011/65/EU; Restriction of Hazardous Substances (RoHS) Product Certifications and Declarations Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link. Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the Engineering a Healthy Planet web page at ni.com/environment. This page contains the environmental ni.com10 PXIe-1083 Specifications
regulations and directives with which NI complies, as well as other environmental information not included in this document. EU and UK Customers
- Waste Electrical and Electronic Equipment (WEEE)—At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/ environment/weee. 电子信息产品污染控制管理办法(中国 RoHS)
- 5 40e 中国 RoHS— NI 符合中国电子信息产品中限制使用某些有害物 质指令(RoHS)。关于 NI 中国 RoHS 合规性信息,请登录 ni.com/environment/ rohs_china。(For information about China RoHS compliance, go to ni.com/ environment/rohs_china.) Backplane Size 3U-sized; 5 peripheral slots. Compliant with IEEE 1101.10 mechanical packaging. PXI Express Specification compliant. Accepts both PXI Express and CompactPCI (PICMG 2.0 R 3.0) 3U modules. Backplane bare-board material UL 94 V-0 Recognized Backplane connectors Conforms to IEC 917 and IEC 1076-4-101, UL 94 V-0 rated System Synchronization Clocks
10 MHz System Reference Clock: PXI_CLK10
© National Instruments 11 PXIe-1083 Specifications
Maximum slot-to-slot skew 250 ps Accuracy ±25 ppm max (guaranteed over the operating temperature range) Maximum jitter 5 ps RMS phase-jitter (10 Hz–1 MHz range) Duty-factor 45% to 55% Unloaded signal swing 3.3 V ±0.3 V Note For other specifications, refer to the PXI-1 Hardware Specification.
100 MHz System Reference Clock: PXIe_CLK100 and PXIe_SYNC100
Maximum slot-to-slot skew 100 ps Accuracy ±25 ppm max (guaranteed over the operating temperature range) Maximum jitter 3 ps RMS phase-jitter (10 Hz to 12 kHz range), 2 ps RMS phase-jitter (12 kHz to 20 MHz range) Duty-factor for PXIe_CLK100 45% to 55% Absolute differential voltage (When terminated with a 50 Ω load to 1.30 V or Thévenin equivalent) 400 mV to 1000 mV Note For other specifications, refer to the PXI-5 PXI Express Hardware Specification. ni.com12 PXIe-1083 Specifications
for installing the optional rack mount kits. Figure 1. PXIe-1083 Chassis Dimensions (Front)
Figure 2. PXIe-1083 Chassis Dimensions (Side) Figure 3. PXIe-1083 Chassis Dimensions (Bottom) 1 The operating range is guaranteed by design.
2 This product meets the requirements of the environmental standards for electrical
equipment for measurement, control, and laboratory use.
3 This product meets the requirements of the environmental standards for electrical
equipment for measurement, control, and laboratory use. © 2022 National Instruments Corporation.
W arranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty. Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty. ■ Typical specifications describe the performance met by a majority of models. ■ Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing. Specifications are Typical unless otherwise noted. Conditions Specifications are valid at 25 °C unless otherwise noted. Analog Input Number of channels 32 single-ended or 16 differ ential ADC resolution 16 bits DNL No missing codes guaranteed INL Refer to AI Ab solute Accuracy. Sample rate © National Instruments 16 PXIe-6363 Specific ations
Figure 1. AI <0..31> CMRR
10 V Range
5 V Range
0.1 V Range
Figure 2. AI <0..31> Small Signal Bandwidth
Table 1. Settling Time for Multichannel Measurements Figure 3. Settling Error versus Time for Differ ent Source Impedances
Source AI <0..31>, APFI <0,1> Functions Start Trigger, Reference Trigger, Pause Trigger, Sample Clock, Convert Clock, Sample Clock Timeb ase Source level AI <0..31> ±Full scale APFI <0,1> ±10 V Resolution 16 bits Modes Analog edge triggering, analog edge triggering with hysteresis, analog windo w triggering Bandwidth (-3 dB) AI <0..31> 3.4 MHz APFI <0,1> 3.9 MHz Accuracy ±1% of range APFI <0,1> characteristics Input impedance 10 kΩ Coupling DC Protection © National Instruments 20 PXIe-6363 Specific ations
Table 2. AI Absolute Accuracy
Reference tempco 1 ppm/°C INL error 60 ppm of range Absolut eAccuracy = Reading · (GainError) + Range · (OffsetError) + NoiseUncertainty ■ GainError = ResidualGainError + GainTempco · (TempChangeFromLastInternalCal) + ReferenceTempco · (TempChangeFromLastExternalCal) ■ OffsetError = ResidualOffsetError + OffsetTempco · (TempChangeFromLastInternalCal) + INLError ■ NoiseUncertainty = Random Noise 3 10, 000 for a coverage factor of 3 σ and averaging 10,000 points. AI Absolut e Accuracy Example For example, on the 10 V range, the absolute accuracy at full scale is as follows: ■ GainError: 48 ppm + 13 ppm · 1 + 1 ppm · 10 = 71 ppm ■ OffsetError: 13 ppm + 21 ppm · 1 + 60 ppm = 94 ppm ■ NoiseUncertainty: 315 µV 3 10, 000 = 9.4 µV ■ Absolut eAccuracy: 10 V · (GainError) + 10 V · (OffsetError) + NoiseUncertainty = 1,660 µV Analog Output Number of channels 4 © National Instruments 22 PXIe-6363 Specific ations
DNL ±1 LSB Monotonicity 16 bit guaranteed Maximum update rate (simultaneous) 1 channel 2.86 MSample/s 2 channels 2.00 MSample/s 3 channels 1.54 MSample/s 4 channels 1.25 MSample/s Timing accuracy 50 ppm of sample rate Timing resolution 10 ns Output range ±10 V, ±5 V, ±external reference on APFI <0,1> Output coupling DC Output impedance 0.2 Ω Output current drive ±5 mA Overdrive protection ±25 V Overdrive current 26 mA Power-on state ±5 mV 23 ni.com PXIe-6363 Specific ations
Power-on/off glit ch 1.5 V peak for 200 ms Output FIFO size 8,191 samples shared among channels used Data transfers DMA (scatter-gather), programmed I/O AO waveform modes Non-periodic waveform, periodic waveform r egeneration mode from onboard FIFO, periodic waveform regeneration from host buffer including dynamic update Settling time, full-scale step 15 ppm (1 LSB) 2 µs Slew rate 20 V/µs Glitch energy at midscale transition, ±10 V r ange 10 nV · s External Reference APFI <0,1> characteristics Input impedance 10 kΩ Coupling DC Protection, device on ±30 V Protection, device off ±15 V Range ±11 V Slew rate 20 V/μs © National Instruments 24 PXIe-6363 Specific ations
Figure 4. AO <0..3> External Reference Bandwidth Table 3. AO Absolute Accuracy of the last external calibration.
■ GainErr or = ResidualGainError + GainTempco · (TempChangeFromLastInternalCal) + ReferenceTempco · (TempChangeFromLastExternalCal) ■ OffsetError = ResidualOffsetError + OffsetTempco · (TempChangeFromLastInternalCal) + INLError Digital I/O/PFI Static Characteristics Ground reference D GND Direction control Each terminal individually programmable as input or output Pull-down resistor Typical 50 kΩ Minimum 20 kΩ Input voltage protection ±20 V on up to two pins Caution S tresses beyond those listed under the Input voltage protection specification may cause permanent damage to the device. Waveform Characteristics (Port 0 Only) Terminals used Port 0 (P0.<0..31>) Port/sample size Up to 32 bits © National Instruments 26 PXIe-6363 Specific ations
Waveform generation (DO) FIFO 2,047 samples Waveform acquisition (DI) FIFO 255 samples DI Sample Clock frequency 0 MHz to 10 MHz, system and bus activity dependent DO Sample Clock frequency Regenerate from FIFO 0 MHz to 10 MHz Streaming from memory 0 MHz to 10 MHz, system and bus activity dependent Data transfers DMA (scatter-gather), programmed I/O Digital line filter settings 160 ns, 10.24 μs, 5.12 ms, disable PFI/Port1/Port 2 Functionality Functionality Static digital input, static digital output, timing input, timing output Timing output sources Many AI, AO, counter, DI, DO timing signals Debounce filter settings 90 ns, 5.12 μs, 2.56 ms, custom interval, disable; programmable high and lo w transitions; selectable per input Recommended Operating Conditions Input high voltage (VIH) Minimum 2.2 V Maximum 5.25 V 27 ni.com PXIe-6363 Specific ations
Input low voltage (VIL) Minimum 0 V Maximum 0.8 V Output high current (IOH) P0.<0..31> -24 mA maximum PFI <0..15>/P1/P2 -16 mA maximum Output low current (IOL) P0.<0..31> 24 mA maximum PFI <0..15>/P1/P2 16 mA maximum Digital I/O Characteristics Positive-going threshold (VT+) 2.2 V maximum Negative-going threshold (VT-) 0.8 V minimum Delta VT hysteresis (VT+ - VT-) 0.2 V minimum IIL input lo w current (V IN = 0 V) -10 μA maximum IIH input high curr ent (VIN = 5 V) 250 μA maximum © National Instruments 28 PXIe-6363 Specific ations
Position measurements X1, X2, X4 quadrature encoding with Channel Z reloading; two- pulse enc oding Output applications Pulse, pulse train with dynamic updates, frequency division, equiv alent time sampling Internal base clocks 100 MHz, 20 MHz, 100 kHz External base clock fr equency
0 MHz to 25 MHz; 0 MHz to 100 MHz on PXIe_DSTAR <A,B>
Base clock accuracy 50 ppm Inputs Gate, Source, HW_Arm, Aux, A, B, Z, Up_Down, Sample Clock Routing options for inputs Any PFI, PXIe_DSTAR<A,B>, PXI_TRIG, PXI_STAR, analog trigger, many int ernal signals FIFO 127 samples per counter Data transfers Dedicated scatter-gather DMA controller for each counter/timer, pr ogrammed I/O Frequency Generator Number of channels 1 Base clocks 20 MHz, 10 MHz, 100 kHz Divisors 1 to 16 Base clock accuracy 50 ppm 31 ni.com PXIe-6363 Specific ations
Phase-Locked Loop (PLL) Number of PLLs 1 Reference clock locking frequency PXIe_DSTAR<A,B> 10 MHz, 20 MHz, 100 MHz PXI_STAR 10 MHz, 20 MHz PXIe_CLK100 100 MHz PXI_TRIG <0..7> 10 MHz, 20 MHz PFI <0..15> 10 MHz, 20 MHz Output of PLL 100 MHz Timebase; other signals derived from 100 MHz Timebase including
20 MHz and 100 kHz Timeb
Source Any PFI, PXIe_DSTAR<A,B>, PXI_TRIG,PXI_STAR Polarity Software-selectable f or most signals Analog input function Start Trigger, Reference Trigger, Pause Trigger, Sample Clock, Conv ert Clock, Sample Clock Timebase Analog output function Start Trigger, Pause Trigger, Sample Clock, Sample Clock Timeb ase Counter/timer functions Gate, Source, HW_Arm, Aux, A, B, Z, Up_Down, Sample Clock © National Instruments 32 PXIe-6363 Specific ations
Digital waveform generation (DO) func tion Start Trigger, Pause Trigger, Sample Clock, Sample Clock Timeb ase Digital waveform acquisition (DI) func tion Start Trigger, Reference Trigger, Pause Trigger, Sample Clock, Sample Clock Timeb ase Device-to-Device Trigger Bus Input source PXI_TRIG <0..7>, PXI_STAR, PXIe_DSTAR<A,B> Output destination PXI_TRIG <0..7>, PXIe_DSTARC Output selections 10 MHz Clock; frequency generator output; many internal signals Debounce filter settings 90 ns, 5.12 μs, 2.56 ms, custom interval, disable; programmable high and lo w transitions; selectable per input Bus Interface Form factor x1 PXI Express peripheral module, specification rev 1.0 compliant Slot compatibility x1 and x4 PXI Express or PXI Express hybrid slots DMA channels 8, can be used for analog input, analog output, digital input, digital output, c ounter/timer 0, counter/timer 1, counter/timer 2, counter/timer 3 Power Requirements Caution The pr otection provided by the device can be impaired if the device is used in a manner not described in the X Series User Manual. 33 ni.com PXIe-6363 Specific ations
+3.3 V 1.6 W +12 V 19.8 W Current Limits Caution E xceeding the current limits may cause unpredictable device behavior. +5 V terminal (connector 0) 1 A maximum[1] +5 V terminal (connector 1) 1 A maximum[1] P0/PFI/P1/P2 and +5 V terminals combined 2 A maximum Physical Characteristics Printed circuit board dimensions Standard 3U PXI Weight 215 g (7.6 oz) I/O connectors Module connector 68-Pos Right Angle Dual Stack PCB-Mount VHDCI (Receptacle) Cable connector 68-Pos Offse t IDC Cable Connector (Plug) (SHC68-*) Note F or more information about the connectors used for DAQ devices, refer to the document, NI DAQ Device Custom Cables, Replacement © National Instruments 34 PXIe-6363 Specific ations
Connectors, and Screws, b y going to ni.com/info and ent ering the Info Code rdspmb. Calibration Recommended warm-up time 15 minutes Calibration interval 2 years Maximum Working Voltage Maximum w orking voltage refers to the signal voltage plus the common-mode voltage. Channel to earth 11 V, Measurement Category I Measurement Category I is for measurements performed on circuits not directly c onnected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics. Caution Do not connect the system to signals or use for measurements within Measurement Categories II, III, or IV. Note Measurement Categories CAT I and CAT O are equivalent. These test and measurement circuits are for other circuits not intended for direct connection to the MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV. 35 ni.com PXIe-6363 Specific ations
T emperature and Humidity Temperature Operating 0 °C to 55 °C Storage -40 °C to 71 °C Humidity Operating 10% to 90% RH, noncondensing Storage 5% to 95% RH, noncondensing Pollution Degree 2 Maximum altitude 2,000 m Indoor use only. Shock and Vibr ation Refer to the X Series User Manual for more information about meeting these specifications. Operational shock 30 g peak, half-sine, 11 ms pulse Random vibration Operating 5 Hz to 500 Hz, 0.3 grms © National Instruments 36 PXIe-6363 Specific ations
Nonoperating 5 Hz to 500 Hz, 2.4 grms Environmental Standards This pr oduct meets the requirements of the following environmental standards for electrical equipment. ■ IEC 60068-2-1 Cold ■ IEC 60068-2-2 Dry heat ■ IEC 60068-2-27 Operating shock ■ IEC 60068-2-64 Random operating vibration ■ IEC 60068-2-56 Damp heat (steady state) ■ MIL-PRF-28800F ■ Low temperature limits for operation Class 3, for storage Class 3 ■ High temperature limits for operation Class 2, for storage Class 3 ■ Random vibration for non-operating Class 3 ■ Shock for operating Class 2 Safety Compliance Standards This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use: ■ IEC 61010-1, EN 61010-1 ■ UL 61010-1, CSA C22.2 No. 61010-1 Note For safety certifications, refer to the product label or the Product Certifications and Declarations sec tion. 37 ni.com PXIe-6363 Specific ations
Electromagnetic Compatibility Standards This pr oduct meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: ■ EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity ■ EN 55011 (CISPR 11): Group 1, Class A emissions ■ AS/NZS CISPR 11: Group 1, Class A emissions ■ FCC 47 CFR Part 15B: Class A emissions ■ ICES-001: Class A emissions Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes. Note In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, and heavy-industrial locations. In Europe, Canada, Australia and New Zealand (per CISPR 11) Class A equipment is intended for use only in heavy-industrial locations. Notice For EMC declarations and certifications, and additional information, refer to the Product Certifications and Declarations sec tion. CE Compliance This product meets the essential requirements of applicable European Directives, as f ollows: ■ 2014/35/EU; Low-Voltage Directive (safety) ■ 2014/30/EU; Electromagnetic Compatibility Directive (EMC) ■ 2011/65/EU; Restriction of Hazardous Substances (RoHS) © National Instruments 38 PXIe-6363 Specific ations
Product Certifications and Declarations R efer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, se arch by model number, and click the appropriate link. Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the Engineering a Healthy Planet web page at ni.com/environment. This p age contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. EU and UK Customers
- Waste Electrical and Electronic Equipment (WEEE)—A t the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/environment/weee. 电子信息产品污染控制管理办法(中国 R oHS)
- 5 40e 中国 RoHS— NI符合中国电子信息产品中限制使用某些有害物 质指令(R oHS)。关于 NI 中国 RoHS 合规性信息,请登录 ni.com/environment/ rohs_china。(For information about China RoHS compliance, go to ni.com/ environment/rohs_china.) 1 Has self -resetting fuse that opens when current exceeds this specification. 39 ni.com PXIe-6363 Specific ations © 2022 National Instruments Corporation.