PXD60 TDK | Alldatasheet
Document overview
- Manufacturer or author: TDK-Lambda
- PDF pages: 7
Technical content
60W Single and Dual Output DC-DC converters PXD60 Series 1 Features Benefits The PXD60 industrial DC-DC converters feature wide 4:1 input ranges in a compact 2 x 1” (50.8 x 25mm) industry standard package. With efficiencies up to 92%, the PXD60 series typically draws a low 3mA input current when the remote on/off function is used, prolonging battery life for portable equipment. The modules have six-sided shielding to reduce radiated noise.
- Wide 4:1 Input Range
- Compact 2” x 1” Industry Package
- Certified to IEC/UL/CSA/EN 62368-1
- Low No Load Power Consumption
- Six Sided Shielding
- Supports Dual 12/24V or 24/48V System Voltages
- Less Board Area Needed
- Suitable For Industrial Applications
- Longer Battery Life
- Reduces Radiated Noise https://product.tdk.com/en/power/pxd www.emea.lambda.tdk.com/pxd Model Selector Model Input Output Maximum Maximum No Load Input Efficiency Maximum Load Voltage (V) Voltage (V) Current (A) Power (W) Current (mA) (%) Capacitance (uF) Single Outputs PXD60-24WS3P3 9 - 36 3.3 12 39.6 10 90 32,000 PXD60-48WS3P3 18 - 75 3.3 12 39.6 10 90 32,000 PXD60-24WS05 9 - 36 5 12 60 10 92 30,000 PXD60-48WS05 18 - 75 5 12 60 10 92 30,000 PXD60-24WS12 9 - 36 12 5 60 10 92 5,850 PXD60-48WS12 18 - 75 12 5 60 10 92 5,850 PXD60-24WS15 9 - 36 15 4 60 10 92 3,900 PXD60-48WS15 18 - 75 15 4 60 10 92 3,900 PXD60-24WS24 9 - 36 24 2.5 60 10 92 2,000 PXD60-48WS24 18 - 75 24 2.5 60 10 91 2,000 Dual Outputs PXD60-24WD12 9 - 36 ±12 ±2.5 60 10 91 ±3,900 PXD60-48WD12 18 - 75 ±12 ±2.5 60 10 91 ±3,900 PXD60-24WD15 9 - 36 ±15 ±2 60 10 91 ±2,400 PXD60-48WD15 18 - 75 ±15 ±2 60 10 91 ±2,400 PXD60-24WD24 9 - 36 ±24 ±1.25 60 10 91 ±1,000 PXD60-48WD24 18 - 75 ±24 ±1.25 60 10 91 ±1,000 S Single Output D Dual Output 60 60W Output Power -24W 9 - 36V input -48W 18 - 75V input Blank Positive Logic Remote On/Off -N Negative Logic Remote On/Off 3P3 3.3V Output Voltage 05 5V Output Voltage 12 12V Output Voltage 15 15V Output Voltage 24 24V Output Voltage PXD 60 -24W S 05 -N -HC2 Preferred model Example: PXD60-24WS3P3-N-HC2 Blank No heatsink fitted -HC1 Factory installed heatsink with 7.62mm fins -HC2 Factory installed heatsink with 12.7mm fins -HC3 Factor installed heatsink with 20.32mm fins
Related Products
Type Part Number Description Heatsink kit (User installation) ACC-PX2X1-HC01 HC1 heatsink, thermal pad and 2 clips Heatsink kit (User installation) ACC-PX2X1-HC02 HC2 heatsink, thermal pad and 2 clips Heatsink kit (User installation) ACC-PX2x1-HC03 HC3 heatsink, thermal pad and 2 clips Model PXD60 Input Input Voltage Range - See model selector table Input Surge Voltage Vdc -24W models: 50, -48W models: 100. (1s maximum) Input Shutdown Voltage Vdc -24W models: 7 - 8.8, -48W models: 15 - 17.5 Start-up Time ms 60 typical No Load Current Consumption - See model selector table. Typically 3mA if remote on/off is activated Efficiency - See model selector table Conducted & Radiated EMI - EN55032. See instruction manual on website for external circuitry Immunity - See immunity section Safety Certifications and Markings - IEC/UL/CSA/EN62368-1, CE Mark and UKCA Mark Test Standard Test Level Criteria Notes ESD EN61000-4-2 Air ± 8kV and Contact ± 6kV A - Radiated Susceptibility EN61000-4-3 20V/m A - Surge EN61000-4-5 ± 2kV A (SMDJ58A for PXD60-24W or SMDJ120A for PXD60-48W) Conducted Susceptibility EN61000-4-6 10 Vrms A - Magnetic Fields EN61000-4-8 100A/m continuous; 1000A/m 1s A - Immunity
See website for detailed specifications, test methods and installation manual (1) Measured with a 20MHz bandwidth oscilloscope across an X7R multi-layer ceramic capacitor. 10uF/25V for 3.3 to 15V outputs, 4.7uF/50V for 24V output models (2) The case temperature must be confirmed in end application. The product rating may be affected by airflow direction and physical obstructions near the module. Specifications Model PXD60 Output Output Voltage Tolerance % ±1 Output Voltage Adjustment % Single output only. 3.3V-12V, 48V: ±10, 15V-24V: -10/+20, No adjustment on dual output models. Switching Frequency kHz 225 - 275 Line Regulation % ±0.2 Load Regulation % Single output: ±0.5 Dual output: ±1 Cross Regulation % Dual output: ±5 (Asymmetrical 25% to 100% load change) External Load Capacitance - See model selector table Ripple & Noise (1) mVp-p Single output: 3.3-5V outputs: <100, 12-15V outputs: <150, 24V outputs: <200 Temperature Coefficient %/°C ±0.02 Minimum Load - No minimum load required Transient Loading - 250us recovery time for a 25% load change Overcurrent Protection % 150, hiccup mode Overvoltage Protection V Zener clamp method. 3.3 V: 3.9, 5V: 6.2, 12V: 15, 15V: 20, 24V: 30 (typical) Overtemperature Protection °C Shutdown, typically 115 Remote Sense No remote sense Remote On/Off - Positive Logic (Blank): ON: Open or 3-12V, OFF Short or 0-1.2V Negative Logic (-N suffix): ON: Short or 0-1.2V, OFF: Open or 3-12V Environmental Operating Temperature (2) °C -40 to +105 - see derating section and instruction manual on website (Confirm case temperatures in end system) Maximum Case Temperature °C 105 (Overtemperature Protection 115) Thermal Impedance °C/W No heatsink: 10.8, -HC1: 8.3, -HC2: 7.0, -HC3: 5.7 Storage Temperature °C -55 to +125 Humidity (non condensing) %RH 5 - 95 (Operating & Storage) Cooling - Convection or forced air Altitude m 5,000 (operating) Withstand Voltage (For 1 minute) Vdc Input to output to case 1,600 Isolation Capacitance pF <2200 Vibration (Operating) - MIL-STD-810F Thermal Shock - MIL-STD-810F Other Weight (Typ) g 33 (no heatsink fitted) Size (LxWxH) mm 50.8 x 25.4 x 10.2 (no heatsink fitted) Size (LxWxH) Inches 2 x 1 x 0.4 (no heatsink fitted) Case Material - Copper MTBF - MIL-HDBK-217F, Full Load Hours 858,200 Warranty Years 3
PXD60-48WS12 - Derating Diagram PXD60-48WS12 - Derating Diagram Derating Section The required power reduction depends on the individual device. The example shows the PXD60-48WS12. The points A to G describe the temperatures at which the power reduction starts. For other models, these points can be taken from the table. A B C D E F G Derating Starting Point 20LFM (convection) 100LFM 200LFM 500LFM with HC1 with HC2 with HC3 PXD60-24WS3P3 61°C 77°C 85°C 89°C 71°C 77°C 82°C PXD60-24WS05 50°C 70°C 80°C 85°C 62°C 69°C 76°C PXD60-24WS12 43°C 67°C 77°C 82°C 58°C 65°C 72°C PXD60-24WS15 51°C 72°C 80°C 85°C 64°C 70°C 77°C PXD60-24WS24 51°C 72°C 80°C 85°C 64°C 70°C 77°C PXD60-24WD12 39°C 65°C 75°C 81°C 55°C 62°C 70°C PXD60-24WD15 50°C 71°C 80°C 84°C 62°C 69°C 76°C PXD60-24WD24 48°C 70°C 78°C 84°C 61°C 68°C 75°C PXD60-48WS3P3 61°C 77°C 85°C 89°C 71°C 77°C 82°C PXD60-48WS05 50°C 70°C 80°C 85°C 62°C 69°C 76°C PXD60-48WS12 45°C 68°C 77°C 84°C 59°C 66°C 73°C PXD60-48WS15 44°C 67°C 77°C 82°C 58°C 65°C 73°C PXD60-48WS24 45°C 68°C 78°C 83°C 59°C 66°C 73°C PXD60-48WD12 39°C 65°C 75°C 81°C 55°C 62°C 70°C PXD60-48WD15 45°C 68°C 78°C 83°C 58°C 66°C 73°C PXD60-48WD24 48°C 70°C 79°C 84°C 61°C 68°C 75°C
- All dimensions in inch (mm) Tolerance: x.xx±0.02 [x.x ± 0.5] 2. Pin dimension tolerance ±0.004 [0.10] All dimensions in inch[mm] Pad size(lead free recommended) PIN Function Single Dual 1 +Vin 2 -Vin
3 Ctrl
6 Trim -Vout
- All dimensions in inch [mm] x.xxx±0.010 [x.xx±0.25] HC1 HC2 HC3
PXD60W_260662 April 13th, 2022 V2 PXD60 Series 7 TDK-Lambda France SAS TDK-Lambda Americas TDK Electronics do Brasil Ltda T el: +33 1 60 12 71 65 france@fr .tdk-lambda.com www.emea.lambda.tdk.com/fr Tel: +55 11 3289-9599 sales.br@tdk-electronics.tdk.com www.tdk-electronics.tdk.com/en Tel: +1 800-LAMBDA-4 or 1-800-526-2324 powersolutions@us.tdk-lambda.com www.us.lambda.tdk.com Italy Sales Office T el: +39 02 61 29 38 63 info.italia@it.tdk-lambda.com www.emea.lambda.tdk.com/it Netherlands info@nl.tdk-lambda.com www.emea.lambda.tdk.com/nl TDK-Lambda Germany GmbH T el: +49 7841 666 0 info@de.tdk-lambda.com www.emea.lambda.tdk.com/de Austria Sales Office T el: +43 2256 655 84 info@at.tdk-lambda.com www.emea.lambda.tdk.com/at Switzerland Sales Office T el: +41 44 850 53 53 info@ch.tdk-lambda.com www.emea.lambda.tdk.com/ch Nordic Sales Office T el: +45 8853 8086 info@dk.tdk-lambda.com www.emea.lambda.tdk.com/dk TDK-Lambda UK Ltd. T el: +44 (0) 12 71 85 66 66 info@uk.tdk-lambda.com www.emea.lambda.tdk.com/uk TDK-Lambda Ltd. T el: +9 723 902 4333 info@tdk-lambda.co.il www.emea.lambda.tdk.com/il C.I.S. Commercial Support: T el: +7 (495) 665 2627 T echnical Support: T el: +7 (812) 658 0463 info@tdk-lambda.ru www.emea.lambda.tdk.com/ru TDK-Lambda Corporation Tel: +81-3-6778-1113 www.jp.lambda.tdk.com TDK-Lambda Singapore Pte Ltd. Tel: +65 6251 7211 tls.mkt@sg.tdk-lambda.com www.sg.lambda.tdk.com TDK-Lambda (China) Electronics Co. Ltd . Tel: +86 21 6485-0777 powersolutions@cn.tdk-lambda.com www.lambda.tdk.com.cn TDK India Private Limited, Power Supply Division Tel: +91 80 4039-0660 mathew.philip@in.tdk-lambda.com www.sg.lambda.tdk.com For additional information, please visit https://product.tdk.com/en/power/