www.cd4power.com PX500 Series AC/DC 500W Multiple Output Power Supply PCX500 Series Rev 07/2006 Page of 4
FEATURES
n n n n n n n n n n n n
DESCRIPTION
The PX500 is a family of 500W, multiple-output power supplies developed for a broad range of applications. All outputs are fully isolated and regulated for either positive or negative ground reference. The outputs can also be connected in series to develop higher voltages or in parallel to develop higher currents. The two-switch forward topology used in the PX500 supplies has been field-proven for high reliability. The mag-amp post-regulators used on the auxiliary outputs will support high peak currents. With a global input of 90-264VAC, safety agency approvals to UL950, CSA C22.2 No. 234-M90, and EN60950, EMI compliance to Class B FCC Part 5, the PX500 was designed with globally- deployed product applications in mind. The PX500 is available in various output voltage/ current configurations and with various cover op- tions. Additional features include remote sense compensation, a power fail warning signal, as well as output inhibit. Several models of the PX500 are also available with RoHS compliance. SELECTION GUIDE Model Number Output 1 Output 2 Output 3 Output 4 PX500U3ABFHPHM 5V@80A 2V@2A 2V@2A -- NA PX500U3BBFHPHM 5V@80A 5V@2A 5V@2A -- NA PX500U4CBFHPHM 5V@80A 2V@2A 2V@2A 5V@4A NA PX500U4CBFHPHMC 5V@80A 2V@2A 2V@2A 5V@4A Yes PX500U4EBFHPHM 5V@80A 2V@2A 2V@2A 2V@4A NA PX500U4HBFHPHM 5V@80A 2V@2A 2V@2A 5.2V@0A NA PX500U4HBFHPHMC 5V@80A 2V@2A 2V@2A 5.2V@0A Yes PX500U4HBVHPHM 5V@80A 2V@2A 2V@2A 5.2V@0A NA PX500U4HBVHPHMC 5V@80A 2V@2A 2V@2A 5.2V@0A Yes PX500U4LBFHPHM 5V@80A 2V@2A 2V@2A 3.3V@0A NA PX500U4LBFHPHMC 5V@80A 2V@2A 2V@2A 3.3V@0A Yes Industry Standard 2"x5"x0" Package 500W Power at 0-50ºC Active Power Factor Correction Efficiency up to 75% Power Fail Warning Signal 80A Main Output Remote Sense on Main Output Remote Inhibit Control Class B conducted EMI Performance Global 90-264VAC Input Active Current Sharing on Output V RoHS Compliant INPUT CHARACTERISTICS Parameter Conditions Min Typ Max Units Input Operating Voltage 90 264 Vac Input Frequency 47 63 Hz Input Current 7.0 Arms Power Factor 0.99 Inrush Current 240Vac 70 Apk 20Vac 30 Apk OUTPUT CHARACTERISTICS Parameter Conditions Min Typ Max Units Output Power All line & environmental 500 W Temperature Coefficient After 30min warm up 0.02 %/ºC Voltage Regulation Line -0. +0. %Vo Load -0.5 +0.5 %Vo Cross -0. +0. %Vo Minimum Load V 4 A Minimum Load V2, V3, V4 0 A PARD (Vo) 20MHz bandwidth %Vnom Output Voltage Adjustment All outputs -5 +5 %Vnom Transient Excursion (Vo) 25% load step, A/μsec max slew -3 +3 %Vo Transient Recovery (Vo) 25% load step, A/μsec max slew 400 μsec Output Holdup Time Full load, low line 20 msec Isolation, Pri-Sec 3 kVac Isolation, Pri-Chassis .5 kVac Isolation, Sec-Chassis 500 Vac Current Share Tolerance Output V; Io>25% 0 % Remote Sense Comp. (Vo) 000 mV ISO9001 CERTIFIED
www.cd4power.com PX500 Series AC/DC 500W Multiple Output Power Supply PCX500 Series Rev 07/2006 Page 2 of 4 GENERAL CHARACTERISTICS Parameter Conditions Min Typ Max Units Efficiency Full load, 240Vac 70 75 % Switching Frequency PFC Converter 00 kHz MTBF Mil-HDBK-27E 3 khrs Weight Unpackaged 4 lbs PROTECTION Parameter Conditions/Response Inception Min Nom Max Units Output OverVoltage Protection V; Latching; cycle AC input to re-start 6.0 6.5 7.0 V Output Overload Protection All outputs; individual current limit; automatic recovery 20 %Io Output Power Limit 550 W Thermal Shutdown Automatic Recovery 00 ºC Input Protection Internal line fuse; Littlefuse 3200 or equivalent 0 A ENVIRONMENTAL CHARACTERISTICS Parameter Conditions Min Typ Max Units Ambient Operating Temperature De-rate output power linearly above 50ºC to 250W at 70ºC 0 +50 +70 ºC Ambient Storage Temperature -20 +85 ºC Operating Humidity Non-condensing 0 90 % Storage Humidity Non-condensing 5 90 % Altitude Operating. De-rate operating ambient temperature by 2Cº per 000ft above 5000ft. -200 0000 ft Storage -200 50000 ft ELECTROMAGNETIC COMPATIBILITY (EMC) Characteristic Compliance Input Current Harmonics EN6000-3-2, Class A Conducted Emissions CFR Title 47, Part 5, Sub-part B, Class B (when the cover option is employed) EN55022, Class A CERTIFICATIONS Agency/Characteristic Standard UL UL950 & UL02 (File Number E4675) CSA CSA 22.2 No. 234-M90, Level 6 (File Number LR 9070-54C) TUV EN60950 (License Number R9576030) CE LVD Directive; self-certified RoHS EN Directive 2002/95/EC; self-certified (see selection guide table on page for compliance) SELV Self-certified Vibration MIL-STD-80D, Method 54.3, Procedure I; self-certified Shock MIL-STD-80D, Method 56.3, Procedure I; self-certified
www.cd4power.com PX500 Series AC/DC 500W Multiple Output Power Supply PCX500 Series Rev 07/2006 Page 3 of 4 MECHANICAL DIMENSIONS (Top-Mounted Fan Cover, Option “F”) MECHANICAL DIMENSIONS (End-Vented Fan Cover, Option “V”)
www.cd4power.com PX500 Series AC/DC 500W Multiple Output Power Supply PCX500 Series Rev 07/2006 Page 4 of 4 C&D Technologies, Inc. reserve the right to alter or improve the specification, internal design or manufacturing process at any time, without notice. Please check with your supplier or visit our website to ensure that you have the current and complete specification for your product before use. ©C&D Technologies, Inc. 2006 No part of this publication may be copied, transmitted or stored in a retrieval system or reproduced in any way including, but not limited to, photography, photocopy, magnetic or other recording means, without prior written permission from C&D Technologies, Inc. Instructions for use are available from www.cd4power.com C&D Technologies Cabot Boulevard, Mansfield, MA 02048-5, USA Tel: + (508) 339-3000 Fax: + (800) 233-2765 email: sales@cdtechno.com C&D Technologies
3400 E Britannia Drive, Tucson,
Arizona 85706, USA Tel: + (800) 547-2537 Fax: + (520) 74-4598 email: pedmktg@cdtechno.com C&D Technologies (NCL) Ltd Tanners Drive, Blakelands North Milton Keynes MK4 5BU, UK Tel: +44 (0)908 65232 Fax: +44 (0)908 67545 email: info@cdtechno-ncl.com SAFETY AGENCY RATINGS Input Voltage 20/240Vac Input Current 8A-4A MODEL NUMBERING PX Product Family
500 Maximum continuous output power in Watts
x Number of outputs (3 or 4) x Output voltage & current configuration (see Selection Guide table on page for details) B Conducted emissions compliance level x Cover Options (F, V) H Remote Inhibit/Enable Logic (Logic enables output) P Power Factor Corrected H Power Fail Warning Logic (Logic indicates AC applied) M Active current sharing on Main output (V) CONNECTIONS INPUT (Terminal Block TB) Ref TB- Chassis Ground G TB-2 Input Neutral N TB-3 Input Line L OUTPUT (Terminal Block TB2) Ref TB2- Output 4 Return -V4 TB2-2 Output 4 +V4 TB2-3 Output 3 Return -V3 TB2-4 Output 3 +V3 TB2-5 Output 2 Return -V2 TB2-6 Output 2 +V2 CONTROL (Molex PN 22-28-050) Ref J- Remote Sense + S- J-2 Remote Sense - S+ J-3 V Current Share CS J-4 Remote Inhibit RI J-5 AC Power Fail Warning PFW