Features
Applications
Pressure Range [PSIA or PSIS] Electrical
- Oil-filled MEMS technology
- Absolute and sealed gage configurations
- Fully hermetic welded design
- Qualifications: RTCA DO-160 and MIL-STD-810
- Proprietary ASIC technology for high accuracy
- Temperature compensated performance with diagnostic capability
- EMC, lightning, and ESD protected Sensata is the world leader in the production and distribution of pressure sensors. With decades of experience in developing and manufacturing our products in-house, we can offer our customers a unique value proposition: high-quality products at a reduced cost. We pride ourselves on our strict quality and reliability standards, which are met through our in-house manufacturing processes. Our latest offering, the AMP (Agile Modular Pressure) series, builds upon this legacy by providing an off-the-shelf solution for any pressure application. This versatile series is designed to meet the specific needs of commercial, civil, and military applications.
- Engine monitoring and control
- Bleed air
- Flight control
- Hydraulic actuation
- Health and usage monitoring systems (HUMS)
- Cabin air and climate controls
- Landing gear
- Brakes
- Tire pressure monitoring systems (TPMS)
- Space and satellite
- APU systems and more… From 0 to… 25 50 75 100 150 200 300 500 1000 1500 2000 3000 4000 5000 Consult Sensata for custom configurations Proof Pressure Factor 3x 3x 3x 3x 3x 2x 2x 2x 2x 2x 2x 2x 1.5x 1.5x Burst Pressure Factor 5x 5x 5x 5x 5x- 3x 3x 3x 3x 3x 3x 3x 2.5x 2x Output Signal Un-Amplified Bridge Output 10 mV/V 4-20 mA Two wire 0.5-4.5 VDC Single-ended output 0.5-9.5 VDC Single-ended output 0-5 VDC Single-ended output 0-10 VDC Single-ended output 0.5-4.5 VDC Differential output 0.5-9.5 VDC Differential output 0-5 VDC Differential output 0-10 VDC Differential output Operating Supply Voltage
10 VDC
VDC 10-36 VDC 10-36 VDC 10-36 VDC 12-36 VDC 10-36 VDC 10-36 VDC 10-36 VDC 12-36 VDC Response Time T63 < 2 ms T63 < 5 ms Insulation Resistance 100 MΩ @ 500 VDC Dielectric Strength < 2mA, 500 VAC @ 60Hz for 60 sec < 2mA, 250 VAC @ 60Hz for 60 sec Output Impedance (25°C) 4000 Ω Max @ 25°C 100 Ω Max @ 25°C
sensata.com Page 2 Copyright © 2023 Sensata Technologies, Inc. Environmental Accuracy (See Charts 1 and 2) Mechanical Qualification Testing Operating Temperature Range -55°C to 150°C(-65 to 300°F) -55°C to 125°C(-65 to 257°F) Storage Temperature Range -55°C to 150°C(-65 to 300°F) -55°C to 150°C(-65 to 300°F) MTBF > 150K flight ours > 75K flight hours Vibration 20Gpk, Sinusoidal from 10 to 2000 Hz Shock 50G Half Sine Wave, 11 msec. Media Compatibility Fuel, oil, air, hydraulic fluid, and other fluids compatible with 300-series and 17-4 PH stainless steel Total Error Band (incl. Accuracy, Linearity, Repeatability, Hysteresis, and Temperature) ±1.5% of FSO from -55°C to +150°C ±1.0% of FSO from 0°C to +100°C Increasing to ±2% @ -55°C and +125°C Pressure Ports 7/16-20 UNJF-3F per AS4395E04 7/16-20 UNJF-3F per AS4375E04 Electrical Connection (See Table 2 for pin assignment) D38999/25YA35CN (6-pin) MIL-DTL-26482 Series 1 (6-pin) MIL-DTL-26482 Series 1 (4-pin) Certification RTCA DO-160, MIL-STD-810, MIL-STD-461, RTCA DO-254 Documentation Acceptance Test Procedure (ATP) on 100% of units SCHEMATIC DIAGRAMS Note: All other pins not connected ACCURACY
Rev.06/08/2023 Page 3 CONTACT US Copyright © 2023 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, valuation, and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements, and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED, OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY , AND SAFETY-ELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA support@sensata.com +1(508)236-3800 sensata.com ORDERING OPTIONS Example : PX500-3000-A-A-1-A Family Pressure Range 0-25 to 0-5000 psi Pressure Reference A = Absolute S = Sealed Gage Pressure Connection A = 7/16-20 UNJF per AS4395E04 B = 7/16-20 UNJF per AS4375E04 Electrical Connection 1 = D38999/25YA35CN (6-pin) 2 = MIL-DTL-26482 Series 1 (6-pin) 3 = MIL-DTL-26482 Series 1 (4-pin) Electrical Input / Output Output Input (Supply) A = Unamplified 10 mV/V 10 VDC Regulated B = Amplified 4-20 mA, two-wire 24 – 32 VDC C = Amplified 0.5-4.5 VDC, Single-ended output 10 – 36 VDC D = Amplified 0.5-9.5 VDC, Single-ended output 10 – 36 VDC E = Amplified 0-5 VDC, Single-ended output 10 – 36 VDC F = Amplified 0-10 VDC, Single-ended output 12 – 36 VDC CD = Amplified 0.5-4.5 VDC, Differential output 10 – 36 VDC DD = Amplified 0.5-9.5 VDC, Differential output 10 – 36 VDC ED = Amplified 0-5 VDC, Differential output 10 – 36 VDC FD = Amplified 0-10 VDC, Differential output 12 – 36 VDC PX500 - 3000 - A - A - 1 - A DIMENSIONS