Technical content

082%6" 0AGE $%3#2)04)/. 4HE08ISACOMPACTWATT0OWER&ACTOR#ORRECTED MULTIPLEOUTPUTPOWERSUPPLY!LLOUTPUTSAREFULLYISOLATED ANDREGULATED!CTIVECURRENTSHARINGCIRCUITRY TOGETHERWITH CONTROLFUNCTIONSANDALARMOPTIONS SIMPLIFIES. AND REDUNDANTAPPLICATIONS&ANANDDISKDRIVEAPPLICATIONSARE HANDLEDBYTHEPEAKCURRENTRATINGSOFTHEAUXILIARYOUTPUTS 7!44 !#$#0/7%23500,9 0RODUCT$ATA3HEET !'%.#9!002/6!,3 !CTIVE0OWER&ACTOR#ORRECTION (IGH3URGE#URRENT!UXILIARY/UTPUTS &ULLY)SOLATEDAND2EGULATED/UTPUTS #OMPACT3IZEvXvXv /NE 4WO 4HREEAND&OUR/UTPUT-ODELS /PTIONAL#OVER7ITH&AN &%!452%3 )NTERNETHTTPWWWCDPOWERELECTRONICSCOM 0OWER%LECTRONICS$IVISION 5NITED3TATES %"RITANNIA$RIVE 4UCSON !RIZONA 0HONE&AX 0OWER%LECTRONICS$IVISION %UROPE #$4ECHNOLOGIES0OWER%LECTRONICS ,TD 3HANNON)NDUSTRIAL%STATE 3HANNON #O#LARE )RELAND 4EL &AX !Contact Factory for Replacement Model

PX400/402 4/98 REV BPage 2 Input Specifications Parameter Conditions Min Typ Max Units Operating Range 47-63 Hz 90 264 V AC Inrush Current Limiting

120 VAC, cold start 30 A PK

240 VAC, cold start 60 A PK

Efficiency Nominal line and full load 75 % Power Factor Correction (PFC) 0.99 Meets IEC 1000-4-7/EN61000-3-2 (formerly IEC 555-2) Remote Sense Remote Sense is provided on Output #1 and will compensate for 1.0V of line drop. Remote Sense leads are protected against open, short and reversal. Remote On/Off The power supply is turned on with a TTL logic ‘1’ (or open) signal and turned off by a switch closure or TTL logic ‘0’ referenced to (-) sense terminal. Consult the factory for other options. Over Voltage Protection Output #1: 6.5V , ±0.5 V DC The power supply will latch off until AC power is cycled. Over Current Protection Individual current limit on all outputs. Automatic recovery upon fault removal. Transient Response The peak output voltage excursion will not exceed 2% and will recover within 1% in 200 μsec for a 25% step load. Output Isolation All outputs are fully isolated. Reverse Voltage Protection All outputs are protected to rated load current. Power Fail Signal Upon AC input voltage removal, the power fail signal drops to logic zero at least 10msec before loss of DC output. Upon AC input turn-on, signal remains low until outputs are in regulation. Consult the factory for other options. N+1 Load Share (PX402) Output #1 has active load sharing circuitry. Units will load share within 1% of the Maximum Rated Load. Over Temperature Protection Thermal switch turns off power supply if overheating occurs and automatically restarts. Safety UL Recognized: UL File Number E14675 (1950 & 1012) CSA Certified: CSA File Number LR 9070-154C (C22.2 No9. 234-M90, Level 6) TUV License Number: R9576029 (EN60950) (IEC950) Cooling The unit is designed to operate with 40 CFM of airflow.

PX400/402 4/98 REV B Page 3 Output Specifications Parameter Limits Regulation Line ± 0.1% Load ±0.5% Cross ±0.1% Minimum Load Output #1 2.5A Hold-Up Time 30mSec at Full Load Parameter Conditions Min Typ Max Units Voltage Adustment Range ±5 % PARD 20 MHz bandwidth 0.5 % P-P Temperature Operating 04 0 ° C Storage -20 +85 °C Temperature Coefficient (T C) After half hour warm-up ± 0.02 % /°C Note: Peak current ratings are for 10sec maximum. Total power not to exceed 400 watts. Output Voltages and Maximum Rated Loads OUTPUT #1 OUTPUT #2 OUTPUT #3 OUTPUT #4 MODEL NUMBER V OUT IMAX VNOM IMAX/IPK VNOM IMAX/IPK VNOM IMAX PX400/402-U3A ±5V 70A ± 12V 15A/17A ± 12V 15A/17A - - PX400/402-U3B ±5V 70A ± 15V 15A/17A ± 15V 15A/17A - - PX400/402-U4C ±5V 70A ± 12V 12A/14A ± 12V 12A/14A ± 5V 3.0A PX400/402-U4D ±5V 70A ± 12V 12A/14A ± 12V 12A/14A ± 24V 2.0A PX400/402-U4E ±5V 70A ± 12V 12A/14A ± 12V 12A/14A ± 12V 3.0A PX400/402-U4F ±5V 70A ± 15V 12A/14A ± 15V 12A/14A ± 5V 3.0A PX400/402-U4G ±5V 70A ± 15V 12A/14A ± 15V 12A/14A ± 24V 2.0A PX400/402-U4H ±5V 70A ± 12V 12A/14A ± 12V 12A/14A ± 5.2V 10.0A PX400/402-U4I ±5V 70A ± 15V 12A/14A ± 15V 12A/14A ± 5.2V 10.0A PX400/402-U4J ±5V 20A ± 17V 3A ± 17V 3A ± 24V 10.0A PX400/402-U4K ±5V 25A ± 12V 10A ± 12V 10A ± 12V 4.0A PX400/402-U4L ±5V 30A ± 12V 10A ± 12V 10A ± 5.2V 3.0A PX400/402-U4M ±5V 30A ± 15V 12A ± 15V 12A ± 5.2V 10.0A PX400/402-U4N ±5V 70A ± 12V 12A ± 12V 12A ± 3.3V 10.0A PX400/402-U4P ±5V 30A ± 12V 10A ± 12V 12A ± 24V 3.0A PX400/402-U4R ±5V 20A ± 15V 4A ± 15V 4A ± 24V 10.0A PX400/402-U4S ±5V 20A ± 12V 8A ± 12V 3A ± 24V 10.0A

PX400/402 4/98 REV BPage 4 Mechanical 0.700 0.550 3.900 10.000 8.500 2.148 4.850 0.040 COVER TB1 Maximum depth of mounting screws is 0.156” TB2 5V Return TOP VIEW The information provided herein is believed to be reliable; however, C&D Technologies assumes no responsibility for inaccuracie s or omissions. C&D Technologies assumes no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Pr ices and specifications are subject to change without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. C&D Tec hnologies does not authorize or warrant any C&D Technologies product for use in life support devices/systems or in aircraft control applications. NOTES: All measurements are in inches FAN MOUNTED ON COVER ADDS 1.30”. COOLING: The PX400/402 is designed to operate with 40 CFM airflow. SHOCK AND VIBRATION: The PX400/402 family meets the requirements of MIL STD-810D. (Vibration-Method 514.3 Procedure I; Shock-Method 516.3 Procedure I.) WEIGHT: Approximately 4 lbs. J9 Connector J9 Connector PIN FUNCTION Molex No. 1 - Sense Connector 22-28-1050 2 + Sense

3 Current Share

4 Remote Inhibit

5 Power Fail

Model PX402 features Active Current Sharing Standard Options are shown, consult factory for other available options. Pin Specifications Connector Specifications Terminal Block 1 Terminal Block 2 POS FUNCTION POS FUNCTION

1 Ground 1 -V4

2 AC Neutral 2 +V4

3 AC Line 3 -V3