Table 1. Electrical Specifications

5 Vdc

3.3 Vdc

5 Vdc supply

3.3 Vdc supply

Table 2. Performance Specifications (At 25 °C [77 °F] and under unless otherwise noted.)

10 V/m (80 MHz to 1000 MHz) per IEC 61000-4-3

3 V per IEC 61000-4-6

200 V/m per ISO 11452-2

1 Dependent on external and internal seal and cable jacket materials. See Table 5 and Figure 5 for temperature range details. 2 Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range. offset, thermal effect on span, and thermal hysteresis. See Figure 1. 25 °C [77 °F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and pressure non-repeatability. See Figure 1. 4 Turn on Time: Duration from power applied until first valid output. 5 Tested using 1.5 m [59.1 in] cable. Table 3. Pressure Reference Definitions perfect vacuum (absolute zero pressure). 1 Sealed gage option only available in pressure ranges at or above 8 bar | 100 psi.

Table 6. Environmental and Mechanical Specifications

100 G per MIL-STD-202F, Method 213B, and Condition C

20 G sweep, 10 Hz to 2000 Hz (at

customer should test the compatibility with the media to ensure that it is correct for the application.

  • Ensure torque specifications are determined for the specific application. Values provided are for reference only. (Mating materials and thread sealants can result in significantly different torque values from one application to the next.)
  • When using mating parts made of stainless steel, use a thread sealant with anti-seize properties to prevent thread galling. Ensure the sealant is rated for the application.
  • Use appropriate tools (such as an open ended wrench or deep well socket) to install transducers.
  • Always hand-start transducers into the hole to prevent cross threading and damage.
  • Ensure that torque is not applied to the electrical connector.
  • Ensure that the proper mating electrical connector with a seal is used to connect the transducer. Improper or damaged seals can compromise ingress protection leading to short circuits. Failure to comply with these instructions may result in product damage. CAUTION PRODUCT DAMAGE TO TUBE PORT Ensure that the temperature of the brass port and plastic connector is maintained below 125 °C during flame brazing. Exposure to temperatures higher than 125 °C can cause permanent product damage and can compromise ingress protection leading to short circuits. Failure to comply with these instructions may result in product damage.

Figure 5. Nomenclature and Order GuideE available. Please contact Honeywell.

2 Custom configurations such as varied cable lengths, end mating connectors,

different O-ring materials, and different pressure ranges are available.

3 Metri-Pack 150 mating connectors with shielded cable and 22 AWG wire

length and part no. 3685302 for 3 m [3.2 ft] cable length.

4 PVC Flame Retardant (FR) type cable is FT1 rated per IEC60332-1; XLPE

non-flame retardant cable is FT2 rated per IEC60332-1. 5 See Table 5 for pressure port materials. 6 See page 3 for Diagnostics Mode information.

7 Sealed gage option only available in pressure ranges at or above 8 bar |

8 See Table 5 for seal material media compatibility.

Figure 6. Metri-Pack Mounting Dimensions (For reference only. mm/[in].) E

Figure 7. Cable Harness Mounting Dimensions Shown by Pressure Port Type (For reference only. mm/[in].) E

To learn more about Honeywell’s sensing and switching products, call 1.800.537.6945 , visit sensing.honeywell.com, or e-mail inquiries to info.sc@honeywell.com Honeywell Safety and Productivity Solutions

9680 Old Bailes Road

Fort Mill, SC 29707 www.honeywell.com Warranty/Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is buyer’s sole responsibility to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. However, Honeywell assumes no responsibility for its use. WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION

  • The information presented in this datasheet is for reference only. Do not use this document as a product installation guide.
  • Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. ADDITIONAL INFORMATION The following associated literature is available on the Honeywell web site at sensing.honeywell.com:
  • Product line guide
  • Product range guide
  • Product installation instructions
  • Application notes: - Heavy Duty Pressure Transducers, PX2 Series and PX3 Series - PX2 Series and PX3 Series Heavy Duty Pressure Transducers for Potential Use in Industrial Refrigeration - PX2 Series and PX3 Series Heavy Duty Pressure Transducers for Potential Use in Industrial HVAC/R

Applications

  • Technical notes: - Total Error Band Specification for Honeywell Heavy Duty Pressure Transducers, PX2 Series and PX3 Series - Media Compatibility for Honeywell Heavy Duty Pressure Transducers, PX2 Series and PX3 Series
  • CAD models 32313757-B-EN | 10/16 © 2016 Honeywell International Inc. Solstice ® N40 is a registered trademark Honeywell International Inc.