Heavy Duty Pressure Transducers PX2 Series 1 bar to 46 bar | 100 kPa to 4.6 MPa | 15 psi to 667 psi Datasheet

sensing.honeywell.com Heavy Duty Pressure Transducers Honeywell’s PX2 Series Heavy Duty Pressure Transducer is a portfolio of highly configurable pressure sensors that use piezoresistive sensing technology with ASIC (Application Specific Integrated Circuit) signal conditioning in a stainless steel housing. The PX2 Series is fully calibrated and compensated for offset, sensitivity, temperature effects and non-linearity using the on-board ASIC. This provides a Total Error Band of ±2% over the operating temperature range of -40 ºC to 125 ºC [-40 °F to 257 °F]. With thousands of possible configurations, the PX2 Series allows Honeywell to meet customer requirements and quickly provide samples. New standard configurations are regularly being added. The PX2 Series is compatible with a variety of harsh media including brake fluid, refrigerants, engine oil, tap water, hydraulic fluids, and compressed air. The wide operating temperature range, ingress protection up to IP69K, and 100 V/m radiated immunity allow for reliable performance in tough environments. These transducers measure absolute or sealed gage pressure. The absolute versions have an internal vacuum reference and an output value proportional to absolute pressure. The sealed gage versions have an internal pressure reference of one atmosphere at sea level. The PX2 Series is available in three pressure ranges, with additional pressure ranges coming soon.

  • 1 bar to 46 bar
  • 100 kPa to 4.6 MPa
  • 15 psi to 667 psi All products are RoHS compliant and are designed and manufactured according to ISO 9001 standards. Count on affordability and availability with these high performing, durable transducers. AFFORDABLE • AvAiLABLE • high pERFORmAncE What makes our transducers better? Affordable: Competitive product cost, over 15,000 standard configurations, and global application support Available: Wide selection of features and a short lead time for samples and production parts High performance: Small Total Error Band, fast response time, and long life High durability: Environmentally tough, wide operating temperature range, and ability to withstand mechanical shock and vibration

sensing.honeywell.com COST EFFECTIVE* The PX2 Series is a precise pressure measurement solution that optimizes system performance at a competitive cost. DESIGNED FOR CONFIGURABILITY* With over 15,000 standard configurations, the PX2 Series easily meets our customers’ specific application needs. APPLICATION EXPERTISE* Knowledgeable application engineers are available to answer customers’ specific design questions during the development of their product. GLOBAL SUPPORT Honeywell’s global presence offers customers immediate product and application support throughout the development cycle, from design to global manufacturing. WIDE SELECTION OF OPTIONS Numerous standard or custom connectors, ports, pressure ranges and types, and output options include:

  • Connector types: Delphi Metri-Pack 150, Micro M12, DIN, Deutsch, cable harness (1 m, 2 m, 3 m, or 5 m).
  • Port types: 1/4-18 NPT, 1/8-27 NPT, 9/16-18 UNF SAE J1926-3, 7/16-20 UNF SAE J1926-3, 1/4 in 45° Flare Female Schrader (7/16-20 SAE J512), M12 x 1.5 ISO 6149-3, G1/4 ISO 1179-3, G1/8 ISO 1179-3.
  • Pressure range: 1 bar to 46 bar | 100 kPa to 4.6 MPa | 15 psi to 667 psi.
  • Pressure reference: Absolute or sealed gage.
  • Output transfer function: Ratiometric, regulated or current. SHORT LEAD TIME Due to the PX2 Series’ configurability, customers can count on a quick response to prototypes. Additionally, dedicated teams and manufacturing processes ensure that product samples are shipped quickly to support your demanding product development cycle. *Competitive Differentiator Affordability minimizes your cost to produce.

Features

Available feature-rich and fast.

sensing.honeywell.com SMALL TOTAL ERROR BAND (TEB) Honeywell specifies TEB, the most comprehensive, clear, and meaningful measurement that provides the transducer’s true accuracy over a compensated temperature range of -40 °C to 125 °C [-40 °F to 257 °F] (see Figure 1). The PX2 Series’ industry-leading TEB of ±2%:

  • Provides excellent transducer interchangeability due to minimal part-to-part variation in accuracy.
  • Eliminates the customers’ need for individual transducer testing and calibration.
  • Supports system accuracy and warranty requirements. FAST RESPONSE TIME A fast response time of <2 ms helps maximize system performance. LONG LIFE A minimum 10 million cycles to operating pressure provides long life in the application.

Dependable, consistent performance. Pressure Non-Linearity Pressure Hysteresis Pressure Non-Repeatability All Possible Errors Offset Full Scale Span Thermal Effect on Offset Thermal Effect on Span Thermal Hysteresis Total Error Band Accuracy= Figure 1: TEB For the PX2 Series

sensing.honeywell.com Durability improves output and endurance. *Competitive Differentiator Compatibility with a wide variety of harsh media, up to IP69K ingress protection, and 100 V/m radiated immunity allow for use in tough environments. WIDE OPERATING TEMPERATURE RANGE A compensated operating temperature range of -40 °C to 125 °C [-40 °F to 257 °F] allows customers to design the same sensor into a variety of applications. SHOCK AND VIBRATION RESISTANT A mechanical shock rating of 100 G per MIL-STD-202F, Method 213B, Cond. F, and a vibration rating of 20 G sweep, 10 Hz to 2000 Hz, increase flexibility of use within the application. GOOD EMC PROTECTION Provides confidence that the transducer will not be damaged by environmental electromagnetic interference. Radiated immunity protection up to 100 V/m (ISO 11452-2) is available. ENERGY EFFICIENT* AC and AD output transfer functions offer a 3.3 V ratiometric output with a <7 ms turn on time, enabling the PX2 Series to be used when energy efficiency is a key requirement. SIX SIGMA DESIGN STANDARDS* Results in the highest level of quality, performance, and consistency so that customers are assured that the transducer will perform to specification.

sensing.honeywell.com INDUSTRIAL HVAC/R May be used to monitor system performance for proper environmental control of:

  • Compressor inlet and outlet pressure
  • Rooftop chillers
  • Compressor rack rooms
  • Refrigerant recovery systems
  • Compressor oil pressure AIR COMPRESSORS May be used to monitor compressor performance and efficiency, specifically:
  • Compressor inlet and outlet pressure
  • Cooling water inlet and outlet pressure
  • Compressor oil pressure
  • Filter pressure drop GENERAL May be used to monitor:
  • Emissions monitoring
  • Factory automation
  • Flow and level
  • Fluid power
  • Foam dispensing
  • Injection molding knock-out valves
  • Lasers
  • Laminating equipment
  • Packaging equipment
  • Pneumatics
  • Pumps
  • Solar energy
  • Sprayers
  • System pressure
  • Valves Potential Applications

Table 1. Electrical Specifications

50 Ohm

10 V/m (80 MHz to 1000 MHz) per IEC 61000-4-3

3 V per IEC61000-4-6

2Transducer will not produce valid output when supply voltage is outside of operating range. 3Applies at 25 °C. See Figure 2 for Regulated Output Supply Voltage. 4Applies at 25 °C. See Figure 3 for Current Output Supply Voltage. permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. 6Absolute voltage applies to potential across power and ground terminals. 7All EMC ratings verified with the Delphi Metri-Pack 150 connector type.

Table 2. Performance Specifications1 1All specifications apply at 25 °C and under operating conditions unless otherwise noted. within the specified performance limits. range may cause permanent damage to the product. the specified performance limits. returned to the operating pressure range. Exposure to higher pressure may cause permanent damage to the product. expected to function after exposure to any pressure beyond the rated burst pressure. This rating is also the case burst rating of the product. 7Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25 °C. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability. 8Offset Error: the maximum deviation in the output signal obtained when the reference pressure is applied at 25 °C relative to the ideal transfer function. change from 10% to 90% of full scale in response to a 0% to 100% full scale step input pressure range. 12Turn On Time: Duration from power applied until first valid output. based on customer-specific usage profile.

Table 4. Mechanical Characteristics Table 3. Pressure Types 1Sealed gage option only available in pressure ranges at or above 100 psi.

Figure 5. Nomenclature and Order Guide1 1Not all catalog listing combinations are available. Custom products are available. Please contact Honeywell. 2Mating connectors available from Honeywell are 3685301 (1 m cable length) and 3685302 (3 m cable length). 3Three-wire cable is required for ratiometric and regulated outputs; two-wire cable is required for current output. 4Three meter and /f_ive meter cables are only available with Output Transfer Function CH = Current, 4 mA to 20 mA. 5Sealed gage option only available in pressure ranges at or above 100 psi. 1/4-18 NPT port type, 150 psi pressure range, absolute pressure reference, regulated, 0.25 Vdc to 10.25 Vdc output transfer function.

2.5 MPa

Figure 6. All Available Standard External Configurations

1 Meter

2 Meter

3 Meter

5 Meter

Figure 7. Connector Dimensions (For reference only: mm/[in].)

3 Vout NC

1IP rating is determined by the electrical connection chosen.

Figure 7. Connector Dimensions, Continued (For reference only: mm/[in].)

1 V+ supply red V+ red supply

2 Vout NC black GND

3 GND RTN white Vout

1IP rating is determined by the electrical connection chosen. 2Three-wire cable is required for ratiometric and regulated outputs; two wire cable is required for current output. 3Three meter and five meter cables are only available with Output Transfer Function CH = Current, 4 mA to 20 mA.

Figure 8. Port Dimensions (For reference only: mm/[in].) 1Straight thread maximum torque is validated to 150% of installation torque. 2Seals for port order codes S1, S2, M1, G1 and G2 are included and assembled to the sensor. 3O-ring material is nitrile 70 durometer -30 ºC to 125 ºC [-22 ºF to 257 ºF].

sensing.honeywell.com PX2 Series ADDITIONAL INFORMATION The following associated literature is available at sensing.honeywell.com:

  • Product line guide
  • Product part listing/nomenclature tree
  • Product range guide
  • Technical Information: – Total Error Band Specification for Honeywell Heavy Duty Pressure Transducers, PX2 Series
  • Datasheet
  • Application information
  • Product installation instructions WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell website, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this issue; however, we assume no responsibility for its use. WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION
  • The information presented in this datasheet is for reference only. Do not use this document as a product installation guide.
  • Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. CAUTION PRODUCT DAMAGE
  • Ensure torque specifications are determined for the specific application. Values provided are for reference only. NPT ports are not specified with torque values. Correct installation is based on the number of Turns From Finger Tight (TFFT). (Mating materials and thread sealants can result in significantly different torque values form one application to the next.)
  • When using NPT ports in stainless steel manifolds, use a thread sealant with anti-seize properties to prevent thread galling. Ensure the sealant is rated for the application.
  • Use appropriate tools (such as an open ended wrench or deep well socket) to install transducers.
  • Always hand-start transducers into the hole to prevent cross threading and damage Failure to comply with these instructions may result in product damage.

50069942 Rev. F - EN February 2014 © 2014 Honeywell International Inc. All rights reserved. Sales and Service Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or email us at info.sc@honeywell.com . Visit us on the Web at sensing.honeywell.com Phone and Fax: Asia Pacific +65 6355-2828 +65 6445-3033 Fax Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax Sensing and Control Honeywell