PX0911 BULGIN | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 6

Technical content

www.elektron-bulgin.com20 BUCCANEER FOR POWER BUCCANEER POWERBUCCANEER POWER

900 Series Buccaneer®

/c5410IP68 rating tested at 1.054kg/sq cm (15lb/sq in) 10m depth for 2 weeks /c541032A, 600V ac/dc rating /c54102, 3, 4, 5, 7 and 10 pole /c5410Plug or socket connection in each body style /c5410Water and dustproof to IP68 when mated /c5410‘Scoop proof’ contacts /c5410Field termination - screw terminations /c5410Positive locating keyways - cannot be mis-connected /c5410Sealing caps available to maintain IP68 rating of unmated connectors /c5410Leading earth contact for 3, 4, 5 and 7 pole versions /c5410Trailing Neutral on 5 pole /c5410Compact design /c5410Easy assembly - no special tools required /c5410Single or 3 phase applications /c5410Bulkhead moulding available for use with flange mounting body for 45˚ or 90˚ mounting (order each separately) /c5410Cost effective solution /c5410Cable accomodation 7-22mm O/D /c5410Two cable connector versions for 15mm and 22mm (maximum) cable diameters /c5410Separate strain relief on large cable version /c5410UL, CSA and VDE approvals IP68 Conns4 - Buccaneer 2010 - Power:Conns4 - Buccaneer 2005v8 8/6/10 16:32 Page 20

www.elektron-bulgin.com 2121 BUCCANEER FOR POWER BUCCANEER POWERBUCCANEER POWER /c5410Mates with in-line flex or panel mounting versions /c5410Positive, fast acting locking ring - can be turned with a gloved hand /c5410Plug or socket versions /c5410PX0 Series13-15mm cable dia. as standard, 7-13mm with additional gland pack /c5410PXA Series 20-22mm cable dia. as standard, 14-20mm with additional gland pack /c5410Strain Relief Clamp (PXA Series only) Standard Cable Large Cable Description Standard Cable Large Cable Description PX0911/02/P PXA911/02/P 2 pole Plug PX0911/02/S PXA911/02/S 2 pole Socket PX0911/03/P PXA911/03/P 3 pole Plug PX0911/03/S PXA911/03/S 3 pole Socket PX0911/04/P PXA911/04/P 4 pole Plug PX0911/04/S PXA911/04/S 4 pole Socket PX0911/05/P PXA911/05/P 5 pole Plug PX0911/05/S PXA911/05/S 5 pole Socket PX0911/07/P PXA911/07/P 7 pole Plug PX0911/07/S PXA911/07/S 7 pole Socket PX0911/10/P PXA911/10/P 10 pole Plug PX0911/10/S PXA911/10/S 10 pole Socket Standard Cable Large Cable Description Standard Cable Large Cable Description PX0921/02/P PXA921/02/P 2 pole Plug PX0921/02/S PXA921/02/S 2 pole Socket PX0921/03/P PXA921/03/P 3 pole Plug PX0921/03/S PXA921/03/S 3 pole Socket PX0921/04/P PXA921/04/P 4 pole Plug PX0921/04/S PXA921/04/S 4 pole Socket PX0921/05/P PXA921/05/P 5 pole Plug PX0921/05/S PXA921/05/S 5 pole Socket PX0921/07/P PXA921/07/P 7 pole Plug PX0921/07/S PXA921/07/S 7 pole Socket PX0921/10/P PXA921/10/P 10 pole Plug PX0921/10/S PXA921/10/S 10 pole Socket PXA911 PX0921 PXA921 /c5410Mates with either PX0911 or PXA911 connectors /c5410Plug or socket versions /c5410PX0 Series 13-15mm cable dia. as standard, 7-13mm with additional gland pack /c5410PXA Series 20-22mm cable dia. as standard, 14-20mm with additional gland pack /c5410Strain Relief Clamp (PXA Series only) FLEX CABLE CONNECTOR IN-LINE FLEX CABLE CONNECTOR Conns4 - Buccaneer 2010 - Power:Conns4 - Buccaneer 2005v8 8/6/10 16:32 Page 21

www.elektron-bulgin.com22 BUCCANEER FOR POWER BUCCANEER POWERBUCCANEER POWER PX0941 /c5410Mates with PX0911 and PXA911 connectors /c5410Supplied with high grade sealing gasket /c5410Supplied with sealing grommets for panel fixing screws (M6 thread recommended) Flange Mounting PX0941/02/P 2 pole Plug PX0941/02/S 2 pole Socket PX0941/03/P 3 pole Plug PX0941/03/S 3 pole Socket PX0941/04/P 4 pole Plug PX0941/04/S 4 pole Socket PX0941/05/P 5 pole Plug PX0941/05/S 5 pole Socket PX0941/07/P 7 pole Plug PX0941/07/S 7 pole Socket PX0941/10/P 10 pole Plug PX0941/10/S 10 pole Socket Panel Mounting PX0931/02/P 2 pole Plug PX0931/02/S 2 pole Socket PX0931/03/P 3 pole Plug PX0931/03/S 3 pole Socket PX0931/04/P 4 pole Plug PX0931/04/S 4 pole Socket PX0931/05/P 5 pole Plug PX0931/05/S 5 pole Socket PX0931/07/P 7 pole Plug PX0931/07/S 7 pole Socket PX0931/10/P 10 pole Plug PX0931/10/S 10 pole Socket PX0931 /c5410Mates with PX0911 and PXA911 connectors /c5410Single hole fixing /c5410Anti-rotation key /c5410High grade sealing gasket /c54103-7mm panel thickness Conns4 - Buccaneer 2010 - Power:Conns4 - Buccaneer 2005v8 8/6/10 16:32 Page 22

www.elektron-bulgin.com 23 Sealing Caps PX0960 Sealing cap for use with PX0911/xx/x and PXA911/xx/x PX0970 Sealing cap for use with all other styles PX0990 Heavy duty sealing cap for use with PX0911/xx/x and PXA911/xx/x PX0991 Heavy duty sealing cap for use with PX0921/xx/x and PXA921/xx/x PX0992 Heavy duty sealing cap for use with PX0931 and PX0941 Gland Packs PX0980 Pack of 3 additional cable glands for PX0911 and PX0921 to suit cable sizes; 11-13mm, 9-11 and 7-9mm dia. PXA980 Pack of 3 additional cable glands for PXA911 and PXA921 to suit cable sizes; 18-20mm, 16-18 and 14-16mm dia. BUCCANEER FOR POWER BUCCANEER POWERBUCCANEER POWER PX0950 & PX0941 PX0960, PX0970 /c5410For use with flange mounting connector PX0941, to give 45˚ or 90˚ angle /c5410Supplied with high grade sealing gasket /c5410Supplied with sealing grommets for panel fixing screws (M6 thread recommended) /c5410Sealing caps to maintain IP68 rating of unmated connectors, with plastic straps ADDITIONAL BULKHEAD ADAPTOR MOULDING ACCESSORIES PX0990, PX0991, PX0992 /c5410Heavy duty sealing caps to maintain IP68 rating of unmated connectors, with stainless steel straps Conns4 - Buccaneer 2010 - Power:Conns4 - Buccaneer 2005v8 8/6/10 16:32 Page 23

www.elektron-bulgin.com24 Electrical: No Poles: 2, 3 4, 5 7 10 † Current Rating: 32A 32A 32A 10A 30A, CSA 25A, CSA 25A, CSA* Voltage Rating: 600V ac/dc 600V ac/dc 430V ac/dc 250V ac/dc Contact Resistance: <10m Ω (initial) Insulation Resistance: >106M Ω (@ 500V dc) Dielectric strength: 2.2kV ac min AC Breakdown voltage: 6kV Operating Temperature Range: –40°C to +85°C Approvals: UL E214972 CSA 1211899 VDE 40003148 CCC Pending Mechanical: Sealing: IP68, EN60529 :1992 tested @ 2 weeks Cable Acceptance: PX0911-PX0921 13 - 15mm O/D standard, 7-13mm with gland pack PXA911-PXA921 20 - 22mm O/D standard, 14 - 20mm with gland pack Contact Accommodation: 2-7 pole - 2.5 to 4mm2 (13 to10AWG) conductor, single or multi stranded 10 pole - 0.75 to 2mm2 (14 to 18AWG) conductor, single or multi stranded Termination: Axial screw terminals Cable Retention force: 22mm dia, 150N 15mm dia, 150N 7mm dia, 80N Gland Nut Torques: PX0 range 13-15mm (Yellow - std.) 3.16Nm (28 lbf.in.) 11-13mm (black) 3.16Nm (28 lbf.in.) 9-11mm (white) 3.16Nm (28 lbf.in.) 7-9mm (dark grey) 3.16Nm (28 lbf.in.) PXA range 20-22mm (Yellow - std.) 3.16Nm (28 lbf.in.) 18-20mm (black) 3.16Nm (28 lbf.in.) 16-18mm (white) 3.16Nm (28 lbf.in.) 14-16mm (dark grey) 3.16Nm (28 lbf.in.) Tightening Torques: Panel mount nut 2.25Nm (20 lbf.in.) Flange & Bulkhead fixing screws 0.9Nm (8 lbf.in.) Term screws - 2 to 5 poles 1.0Nm (9 lbf.in.) max Term screws - 7 pole 0.4Nm (3.5 lbf.in.) max Term screws - 10 pole 0.25Nm (2.2 lbf.in.) max Rear thread PX0931 series M36 x 2-6g Material: Body Mouldings: Polyamide Flammability Rating: UL94V-0 UV Resistance: To EN50021: 1999 Contacts: Machined Solid Brass, Nickel plated O Rings: Nitrile Panel Sealing Gasket: Silicone Rubber Compliant SPECIFICATION Dimensions: Overall dimensions of connectors when mated together PX0911 + PX0921 230 mm max. PXA911 + PXA921 270 mm max. PX0911 + PX0931 135 mm max. (to panel) PXA911 + PX0931 175 mm max. (to panel) PX0911 + PX0941 145 mm max. (to panel, mid point on flange) PXA911 + PX0941 174 mm max. (to panel, mid point on flange) *with 75ºC min. rated cable † approvals pending for 10 Pole version CONTACT LAYOUT 2 pole 3 pole 4 pole 5 pole 7 pole 10 pole BUCCANEER FOR POWER BUCCANEER POWERBUCCANEER POWER Conns4 - Buccaneer 2010 - Power:Conns4 - Buccaneer 2005v8 8/6/10 16:32 Page 24

www.elektron-bulgin.com 25 09 = Standard Cable Accommodation (7-13mm) A9 = Large Cable Accommodation (14-22mm) Body Styles 1 = Flex, 2 = Flex In-line, 3 = Panel, 4 = Flange Panel Contact Termination 1 = Screw Terminal Number Contacts 02 = 2 pole, 03 = 3 pole, 04 = 4 pole, 05 = 5 pole, 07 = 7 pole, 10 = 10 pole Contact Type P = Plug, S = Socket Cable Acceptance PX0 version: Blank = 13-15mm Yellow cable gland (standard) 03 = 11-13mm Black cable gland 02 = 9-11mm White cable gland 01 = 7-9mm Dark Grey cable gland PXA version: Blank = 20-22mm Yellow cable gland (standard) 09 = 18-20mm Black cable gland 08 = 16-18mm White cable gland 07 = 14-16mm Dark Grey cable gland Example: PX0911/07/P/03 = Flex cable connector with standard cable accommodation body, seven pin contacts, with gland to suit 11-13mm cable. BUCCANEER FOR POWER BUCCANEER POWERBUCCANEER POWER Conns4 - Buccaneer 2010 - Power:Conns4 - Buccaneer 2005v8 8/6/10 16:33 Page 25