PowerBlock Micro-Miniature Modular Switching Power Supplies PWB series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 Single 5 Watt Outputs 3.3VDC to 24VDC Universal 90 to 264VAC Input 3,000VAC Input to Output Isolation 0 to +50°C Operation High Efficiency Model Number Output Voltage Output Amps Output Watts Size (inches) PWB-5000 3.3 VDC 1.25 4W 1 x 2 x 0.6 PWB-5001 5 VDC 1 5W 1 x 2 x 0.6 PWB-5002 12 VDC 0.42 5W 1 x 2 x 0.6 PWB-5003 15 VDC 0.33 5W 1 x 2 x 0.6 PWB-5005 24 VDC 0.23 5W 1 x 2 x 0.6 2”L x 1”W x 0.6”H

PowerBlock Micro-Miniature Modular Switching Power Supplies PWB series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 INPUT SPECIFICATIONS Input Voltage, Nominal 90-264VAC Nominal: 100-240VAC Input Frequency 47-63 Hz, 50-60Hz Nom. Inrush Current 20A @ 115VAC, typ 40A @ 230VAC, typ Leakage Current <3.5mA @ 264VAC, 50Hz OUTPUT SPECIFICATIONS Output Voltage/Current See Specific Model Initial Accuracy +/-1%, typ Load Regulation 3.3V & 5V:+/-1%, typ Line Regulation 3.3V & 5V:+/-1%, typ Temperature Coefficient +/-0.03%/°C Ripple/Noise(20Mhz BW) 200-250mV Pk-Pk, max. Overvoltage Protection 120-150%, Auto-recovery * Hold Up Time 10ms, typ. @ nom. input Short Circuit Protection Auto-recovery * Over Current Protection Auto-recovery * GENERAL SPECIFICATIONS Input-Out Isolation 3000VAC Operating Frequency 100 Khz, fixed, typ Efficiency @ nom input 71 - 80%, typ (61% typ for 3.3V) Safety UL/cUL: UL60950-1 2nd ed./ C22.2 60950-1 2nd ed. UL-EU: EN60950-1 2nd ed. CE: EN60601-1-2 CB: IEC60950-1 2nd ed. EMC EN55011 Class B ENVIRONMENTAL SPECIFICATIONS Oper. Temperature 0 to +50°C FL Derate Linearly to 20%L @ 70°C Relative Humidity 0-95%, Non-Condensing Storage Temperature -25 to +71°C * MTBF 380,000 Hrs MIL-HDBK 217, Parts Count Method, 25°C, Ground Benign PHYSICAL SPECIFICATIONS Case Material Rynite, 94V-0 Rated Construction Encapsulated, Soft Pot Weight 1.5 oz (42g) * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. All specifications are typical at nominal input, full load, and 25DegC unless otherwise noted

PowerBlock Micro-Miniature Modular Switching Power Supplies PWB series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 .10 .40in 10.16mm 20.32mm .80in 1.80in 45.72mm 2.63mm 2.54mm .10in .31in 8mm 15.24mm .59in BOTTOM VIEW ACL -Vout +Vout ACN Scale : Finish : Material : Parts No : Parts Name : ASTRODYNE PACIFIC CORP. +/- 0.2 mm Check : Date : Drawing : Tolerance : Unit : File Name : PWB-5000-A221 50.8mm 2.00in 25.57mm 1.01in MECHANICAL SPECIFICATIONS .60in 1.00in

PowerBlock Micro-Miniature Modular Switching Power Supplies PWB series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 OUTPUT DERATING CURVE

PowerBlock Micro-Miniature Modular Switching Power Supplies PWB series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 POWER BLOCK APPLICATION NOTES Output Noise The figure below ia a sample diagram to reduce Output Ripple and Noise. C1 = Electrolytic Capacitor Capacitance = 22uF - 220uF Voltage = Two times rated output voltage L1 = 3uH - 10uH C2 = Electrolytic Capacitor Capacitance = 22uF - 47uF Voltage = Two times rated output voltage C3 = Ceramic Capacitor Capacitance = 0.01uF - 0.1uF Voltage = 50 volt Notes: 1. The use of C1 alone may reduce noise to desired levels, if not use L1, C2 and C3 in addition to C1. 2. The figure above is a suggested circuit. Only by trying true application can levels be tested. EMI The figure below ia a suggested diagram to reduce Electromagnetic Interference (EMI). C1 = 0.22uF X Capacitor L1 = 10mH - 30mH Common Mode, Choke C2, C3 = 220pF Y Capacitors Notes: The diagram above is a recommended circuit, only by trying true application can levels be measured. Inrush Current If desired, the use of a Choke, NTC or Inrush Current Limiter may be used to reduce the Inrush Current 0515