1 Version: A2412

10A, 600V Ultra Fast Surface Mount Rectifier

FEATURES

  • AEC-Q101 qualified
  • Planar technology
  • Low power loss, high efficiency
  • Ideal for automated placement
  • Wettable flank
  • Moisture sensitivity level: level 1, per J-STD-020
  • RoHS Compliant
  • Halogen-free

APPLICATIONS

  • DC to DC converter
  • Automotive application
  • Car lighting
  • Snubber
  • Freewheeling application MECHANICAL DATA
  • Case: TO-277A (SMPC4.6U)
  • Molding compound meets UL 94V-0 flammability rating
  • Terminal: Matte tin plated leads, solderable per J-STD-002
  • Meet JESD 201 class 2 whisker test
  • Polarity: Indicated by cathode band
  • Weight: 0.104g (approximately) KEY PARAMETERS PARAMETER VALUE UNIT IF 10 A VRRM 600 V IFSM 115 A TJ MAX 175 °C Configuration Single die TO-277A (SMPC4.6U) ABSOLUTE MAXIMUM RATINGS (TA = 25°C unless otherwise noted) PARAMETER SYMBOL VALUE UNIT Repetitive peak reverse voltage VRRM 600 V Reverse voltage, total rms value VR(RMS) 420 V Forward current IF 10 A Surge peak forward current single half sine-wave superimposed on rated load t = 8.3ms IFSM 115 A t = 1.0ms 260 Junction temperature TJ -55 to +175 °C Storage temperature TSTG -55 to +175 °C

2 Version: A2412

Junction-to-lead thermal resistance(1) RӨJL 2 °C/W Junction-to-ambient thermal resistance(2) RӨJA 46 °C/W Junction-to-case thermal resistance(2) RӨJC 7 °C/W Thermal Performance Notes: 1. With ideal heat sink 2. Units mounted on PCB (16mm x 16mm Cu pad test board) ELECTRICAL SPECIFICATIONS (TA = 25°C unless otherwise noted) PARAMETER CONDITIONS SYMBOL TYP MAX UNIT Forward voltage(1) IF = 5A, TJ = 25°C VF 1.35 - V IF = 10A, TJ = 25°C 1.53 1.8 V IF = 5A, TJ = 125°C 1.04 - V IF = 10A, TJ = 125°C 1.24 - V Reverse current @ rated VR(2) TJ = 25°C IR - 5 µA TJ = 125°C 6 - µA Junction capacitance 1MHz, VR = 4.0V CJ - pF Reverse recovery time IF = 0.5A, IR = 1.0A, Irr = 0.25A trr - 25 ns IF = 1.0A, di/dt = 50A/µs, VR = 30V 28 - Reverse recovery current IF = 10A, di/dt = 200A/µs, VR = 400V IRM 2.7 - A Reverse recovery charge Qrr 150 - nC Reverse recovery time trr 76 - ns Notes: 1. Pulse test with PW = 0.3ms 2. Pulse test with PW = 30ms

ORDERING INFORMATION

ORDERING CODE PACKAGE PACKING PUUP10JH TO-277A (SMPC4.6U) 6,000 / Tape & Reel

3 Version: A2412

(TA = 25°C unless otherwise noted) Fig.5 Typical Transient Thermal Impedance 0.0001 0.001 0.01 0.1 100 Fig.1 Forward Current Derating Curve Fig.2 Typical Junction Capacitance Fig.3 Typical Reverse Characteristics Fig.4 Typical Forward Characteristics 0 25 50 75 100 125 150 175 100 1000 1 10 100 f=1.0MHz Vsig=50mVp-p 0.001 0.01 0.1 100 1000 10 20 30 40 50 60 70 80 90 100 TJ=25°C TJ=125°C TJ=150°C TJ=175°C 0.1 100 Pulse width 300μs 1% duty cycle TJ=25°C TJ=125°C TJ= -55°C TJ=150°C TJ=175°C CAPACITANCE (pF) INSTANTANEOUS REVERSE CURRENT (μA) PERCENT OF RATED PEAK REVERSE VOLTAGE (%) INSTANTANEOUS FORWARD CURRENT (A) (A) FORWARD VOLTAGE (V) AVERAGE FORWARD CURRENT (A) REVERSE VOLTAGE (V) LEAD TEMPERATURE (°C) PULSE DURATION (s) TRANSIENT THERMAL IMPEDANCE (°C/W)

4 Version: A2412

PACKAGE OUTLINE DIMENSIONS TO-277A (SMPC4.6U) YW F = DATE CODE = FACTORY CODE PUUP10J YWF

5 Version: A2412

Specifications of the products displayed herein are subject to change without notice. TSC or anyone on its behalf, assumes no responsibility or liability for any errors or inaccuracies. Purchasers are solely responsible for the choice, selection, and use of TSC products and TSC assumes no liability for application assistance or the design of Purchasers’ products. Information contained herein is intended to provide a product description only. No license, express or implied, to any intellectual property rights is granted by this document. Except as provided in TSC’s terms and conditions of sale for such products, TSC assumes no liability whatsoever, and disclaims any express or implied warranty, relating to sale and/or use of TSC products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright, or other intellectual property right. The products shown herein are not designed for use in medical, life -saving, or life -sustaining applications. Customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify TSC for any damages resulting from such improper use or sale.