www.panduit.com
applications
Category 6/Class E Exceeds channel requirements of ANSI/TIA-568-C.2 Categor y 6 and channel performance: ISO 11801 Class E standards at sw ept frequencies 1 to 250 MHz FCC and Meets ANSI/TIA-1096-A; contacts plated with 50 microinches of gold ANSI compliance: for super ior performance IEC compliance: Meets IEC 60603-7 PoE compliance: Meets IEEE 802.3af and IEEE 802.3at for P oE applications RoHs compliance: Compliant UL rated: UL 1863 approv ed technical information specifications Category 6/Class E, 8-position, female to female, UTP coupler module shall provide easy plug and play pass through connectivity. Coupler modules shall act as one connecting hardware component in the channel. Coupler modules shall be available individually or installed in a 24-port flat patch panel. Couplers shall be compatible with 6 or 8-position RJ45 UTP patch cords with T568A and T568B wiring schemes. Mini-Com ® TX6™ PLUS UTP Coupler Modules and Patch Panels are a component of the TX6™ PLUS UTP Copper Cabling System. This end-to-end system is interoperable and backwards compatible, providing design flexibility to protect network investments well into the future. Couplers are designed to perform as one connector in the channel, allowing up to 4 couplers in each channel to be used while maintaining channel performance. Couplers are a reliable, modular solution, ideal when setting up networks in a testing environment or during a planned system upgrade. With certified performance to the ANSI/TIA-568-C.2 Category 6 and ISO
11801 Class E standards, this system will
support the following applications:
- Ethernet 10BASE-T , 100BASE-T (Fast Ethernet), 1000BASE-T (Gigabit Ether net)
- 155 Mb/s ATM, 622 Mb/s A TM, 1.2 Gb/s ATM
- T oken Ring 4/16
- Digital video and broadband/baseband analog video
- V oice over Internet Protocol (VoIP) key features and benefits 100% performance Confidence that each coupler will deliver the cr itical electrical tested perfor mance requirements Modular Couplers snap in and out of all Mini-Com ® Faceplates, Modular Patch P anels and industrial bulkheads for easy moves, adds and changes RJ45 interface Industry standard interf ace provides a quick and easy plug and play connection to RJ45 patch cords; bac kwards compatible Identification Can be clearly identified with optional labels and icons f or port identification P opulated patch Factor y installed 24-port patch panel mounts to standard EIA 19" panel version or 23" r acks for greater system flexibility Blockout device Provides a simple and secure method to control access to data (optional) ports while not in use Mini-Com® TX6™ PLUS UTP Coupler Modules and Patch Panel SPECIFICATION SHEET TX6 ™ PLUS UTP Copper Cabling System Mini-Com ® TX6 ™ PLUS UTP Coupler Modules Coupler Module: CC688‡ Mini-Com ® TX6™ PLUS UTP Coupler Patch Panel 24-port, 1 RU: CP24688BL Y TX6500 ™ UTP Copper Cable Plenum: PUP6504*-UY Riser: PUR6504*-UY TX6000 ™ UTP Copper Cable Plenum: PUP6004* Riser: PUR6004* LSZH (60332-1): PUL6004* LSZH (60332-3): PUZ6004* CM: PUC6004* TX6 ™ PLUS UTP Patch Cords CM (foot lengths): UTPSP^Y CM (meter lengths): UTPSP^^MY LSZH (meter lengths): UTPSPL^^MY Mini-Com ® Angled Modular Patch Panels 24-port, 1 RU: CPPLA24WBL Y 48-por t, 2 RU: CPPLA48WBL Y Mini-Com ® Flat Modular Patch Panels 24-port, 1 RU: CPPL24WBL Y 48-por t, 2 RU: CPPL48WBL Y For additional modular and punchdown patch panels, visit www.panduit.com. Accessories Industrial bulkhead: IAEBH Clear dust cap: MDC-C Bloc kout device: PSL-DCJB-^^^ Phone icons: CIPIW -C+ Data icons: CIDIW -C+ ‡To designate color, add suffix BL (Black, IW (Off White), BU (Blue), GR (Green), OR (Orange), RD (Red), IG (International Gray) or YL (Y ellow). * To designate color, add suffix BU (Blue) or WH (White). For additional cable colors, contact customer service. ^ For lengths 1 to 20 feet (one foot increments) and 25, 30, 35, 40 feet, change the length designation in the part number to the desired length. For standard cable colors other than Off White, add suffix BL (Black), BU (Blue), RD (Red), YL (Y ellow), GR (Green), OR (Orange) or VL (Violet). For example, the part number for a blue 15-foot patch cord is UTPSP15BUY . ^^ For lengths 1 to 10 meters (one meter increments) and 2.5, 15, 20, 25, 30, 35, 40 meters, change the length designation in the part number to the desired length. For standard cable colors other than Off White, add suffix BL (Black), BU (Blue), RD (Red), YL (Y ellow), GR (Green), OR (Orange) or VL (Violet). For example, the part number for a blue15-meter patch cord is UTPSP15MBUY . ^^^To designate color other than Red, add suffix BL (Black), BU (Blue), YL (Y ellow), GR (Green), OR (Orange), IW (Off White) or IG (International Gray) at the end of the part number. 10/package. +To designate color other than IW (Off White), replace IW with EI (Electric Ivory), IG (International Gray), BL (Black), BU (Blue), RD (Red), YL (Y ellow), GR (Green), OR (Orange) or VL (Violet) in the part number. 100/package. Note: Mini-Com ® Coupler Modules are not compatible with Panduit® Surface Mount Boxes.
©2015 Panduit Corp. ALL RIGHTS RESERVED. COSP237--WW-ENG Mini-Com® TX6™ PLUS UTP Coupler Modules and Patch Panel WORLDWIDE SUBSIDIARIES AND SALES OFFICES For a copy of Panduit product warranties, log on to www.panduit.com/warranty PANDUIT CANADA Markham, Ontario cs-cdn@panduit.com Phone: 800.777.3300 PANDUIT EUROPE LTD. London, UK cs-emea@panduit.com Phone: 44.20.8601.7200 PANDUIT JAPAN Tokyo, Japan cs-japan@panduit.com Phone: 81.3.6863.6000 PANDUIT SINGAPORE PTE. LTD. Republic of Singapore cs-ap@panduit.com Phone: 65.6305.7575 PANDUIT AUSTRALIA PTY. LTD. Victoria, Australia cs-aus@panduit.com Phone: 61.3.9794.9020 PANDUIT LATIN AMERICA Guadalajara, Mexico cs-la@panduit.com Phone: 52.33.3777.6000 Contact Customer Service by email: cs@panduit.com or by phone: 800.777.3300 Visit us at www.panduit.com For more information Dimensions are in inches. [Dimensions in brackets are metric]. Test Results Mechanical Test Test Method Measurement Typical Test Results Normal Force — Load (grams) >100 Vibration IEC 512-6d Circuit Resistance (mOhms) <40 Shock IEC 512-6c Contact Disturbance (microseconds) <5 Durability IEC 512-9a Circuit Resistance (mOhms) <40 Mating/Unmating IEC 512-13b Mating Force (N) <20 Un-mating Force (N) <20 Termination Cycles IEC 352 Number of Cycles >20 Electrical Test Test Method Measurement Typical Test Results Low Level Circuit Resistance IEC 512-2a Resistance (mOhms) <20 Dielectric Withstand Voltage IEC 512-4a 1000 V, 1 minute Passed Insulation Resistance IEC 512-3a Resistance (MOhms) >500 Environmental Test Method Measurement Typical Test Results Temperature Life IEC 512-9b Circuit Resistance (mOhms) <40 Humidity IEC 512-11c Circuit Resistance (mOhms) <40 Thermal Shock IEC 512-11d Circuit Resistance (mOhms) <40 Climatic Sequence IEC 512-11a Circuit Resistance (mOhms) <40 Flowing Mixed Gas Corrosion IEC 512-11g Circuit Resistance (mOhms) <40 Mini-Com® Category 5e Coupler Module 24-Port Category 5e Coupler Patch Panel Compatible with Industrial Bulkhead (IAEBH) Compatible with Mini-Com® Faceplates and Modular Patch Panels 1.13 [28.6] 19.00 [482.6]1.13 [28.64] 0.71 [18.06] 1.72 [46.7] 0.62 [15.86]