1 Version: A2412
6A, 600V Ultra Fast Surface Mount Rectifier
FEATURES
- AEC-Q101 qualified
- Planar technology
- Low power loss, high efficiency
- Ideal for automated placement
- Moisture sensitivity level: level 1, per J-STD-020
- RoHS Compliant
- Halogen-free
APPLICATIONS
- DC to DC converter
- Automotive application
- Car lighting
- Snubber
- Freewheeling application MECHANICAL DATA
- Case: DO-214AA (SMB)
- Molding compound meets UL 94V-0 flammability rating
- Terminal: Matte tin plated leads, solderable per J-STD-002
- Meet JESD 201 class 2 whisker test
- Polarity: Indicated by cathode band
- Weight: 0.088g (approximately) KEY PARAMETERS PARAMETER VALUE UNIT IF 6 A VRRM 600 V IFSM 75 A TJ MAX 175 °C Package DO-214AA (SMB) Configuration Single die DO-214AA (SMB) ABSOLUTE MAXIMUM RATINGS (TA = 25°C unless otherwise noted) PARAMETER SYMBOL VALUE UNIT Repetitive peak reverse voltage VRRM 600 V Reverse voltage, total rms value VR(RMS) 420 V Forward current IF 6 A Surge peak forward current single half sine-wave superimposed on rated load t = 8.3ms IFSM A t = 1.0ms 170 Junction temperature TJ -55 to +175 °C Storage temperature TSTG -55 to +175 °C
2 Version: A2412
Junction-to-lead thermal resistance RӨJL 12.1 °C/W Junction-to-ambient thermal resistance RӨJA 62 °C/W Junction-to-case thermal resistance RӨJC 13.8 °C/W Thermal Performance Note: Units mounted on PCB (10mm x 10mm Cu pad test board) ELECTRICAL SPECIFICATIONS (TA = 25°C unless otherwise noted) PARAMETER CONDITIONS SYMBOL TYP MAX UNIT Forward voltage(1) IF = 3A, TJ = 25°C VF 1.31 - V IF = 6A, TJ = 25°C 1.47 1.7 V IF = 3A, TJ = 125°C 1.00 - V IF = 6A, TJ = 125°C 1.17 - V Reverse current @ rated VR(2) TJ = 25°C IR - 2 µA TJ = 125°C 4 - µA Junction capacitance 1MHz, VR = 4.0V CJ 29 - pF Reverse recovery time IF = 0.5A, IR = 1.0A, Irr = 0.25A trr - 25 ns IF = 1.0A, di/dt = 50A/µs, VR = 30V 28 - Reverse recovery current IF = 6.0A, di/dt = 200A/µs, VR = 400V IRM 2.6 - A Reverse recovery charge Qrr 123 - nC Reverse recovery time trr 72 - ns Notes: 1. Pulse test with PW = 0.3ms 2. Pulse test with PW = 30ms
ORDERING INFORMATION
ORDERING CODE PACKAGE PACKING PU6JBH DO-214AA (SMB) 3,000/ Tape & Reel
3 Version: A2412
(TA = 25°C unless otherwise noted) Fig.1 Forward Current Derating Curve Fig.2 Typical Junction Capacitance Fig.3 Typical Reverse Characteristics Fig.4 Typical Forward Characteristics Fig.5 Typical Transient Thermal Impedance 0 25 50 75 100 125 150 175 100 1 10 100 f=1.0MHz Vsig=50mVp-p 0.001 0.01 0.1 100 10 20 30 40 50 60 70 80 90 100 TJ=25°C TJ=125°C TJ=150°C TJ=175°C 0.1 Pulse width 300μs 1% duty cycle TJ=25°C TJ=125°C TJ= -55°C TJ=150°C TJ=175°C 0.0001 0.001 0.01 0.1 100 CAPACITANCE (pF) INSTANTANEOUS FORWARD CURRENT (A) (A) INSTANTANEOUS REVERSE CURRENT (μA) AVERAGE FORWARD CURRENT (A) TRANSIENT THERMAL IMPEDANCE (°C/W) PULSE DURATION (s) REVERSE VOLTAGE (V) LEAD TEMPERATURE (°C) PERCENT OF RATED PEAK REVERSE VOLTAGE (%) FORWARD VOLTAGE (V)
4 Version: A2412
PACKAGE OUTLINE DIMENSIONS DO-214AA (SMB) G YW F = GREEN COMPOUND = DATE CODE = FACTORY CODE PU6JB GYWF
5 Version: A2412
Specifications of the products displayed herein are subject to change without notice. TSC or anyone on its behalf, assumes no responsibility or liability for any errors or inaccuracies. Purchasers are solely responsible for the choice, selection, and use of TSC products and TSC assumes no liability for application assistance or the design of Purchasers’ products. Information contained herein is intended to provide a product description only. No license, express or implied, to any intellectual property rights is granted by this document. Except as provided in TSC’s terms and conditions of sale for such products, TSC assumes no liability whatsoever, and disclaims any express or implied warranty, relating to sale and/or use of TSC products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright, or other intellectual property right. The products shown herein are not designed for use in medical, life -saving, or life -sustaining applications. Customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify TSC for any damages resulting from such improper use or sale.