01/98 N/AL 9.12.001.01Our policy is one of continuous research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.

Ordering Information

To order, quote appropriate product number from the tables on the following pages. When ordering Polyester reinforced PVC hose state the length of hose required. l Available in a variety of different types to suit a wide range of applications l All tubing can be used with specific ranges of tube fittings l Nylon and polyurethane tube available in several colours for ease of identification Technical Data Medium: Compressed air (Consult our Technical Service for use with other fluids) Operating Pressure: Refer to specific tubing type on the following pages Operating Temperature: Refer to specific tubing type on the following pages Tube Sizes Nylon: 4, 5, 6, 8, 10, 12, 14, 16, 22, 28 mm O/D Polyurethane: 4, 5, 6, 8, 10, 12 O/D Extraflexible Nylon: 8, 10, 12, 15 mm O/D Polyester reinforced PVC hose: 3, 5, 6.3, 8, 10, 12.5, 19, 25 mm I/D Polyester reinforced PVC hose assemblies: 4, 5, 6, 8, 10, 12, 16, 22, 28 O/D Metal Braided: 4, 5, 6, 8, 10, 12, 28 mm Copper – half hard and annealed: 4, 5, 6, 8, 10, 12, 16, 22, 28 mm O/D Double Wall Brazed Steel: 4, 6, 8, 10, 12 mm O/D Materials Nylon tube: nylon (polyamide) type 11 or 12 fully plasticised Polyurethane Polyester reinforced PVC: high quality electrically non- conductive plasticised PVC hose, high tensile polyester fibre braiding, galvanised steel ‘O’ clips and brass tailpieces on assembled hoses Metal braided hose: E90 nitrile rubber hose, galvanised steel braiding wire, brass ferrules, copper tailpieces Copper tube: phosphorous de-oxidised non arsenical copper to BS6017 grade Cu-DHP Double wall brazed steel: copper coated steel strip with plated Tubing & Hose Metric Nylon, Polyurethane, Polyester Reinforced PVC, Metal Braided Rubber, Copper, Double Wall Brazed Steel

O/D I/D Product number Corporate Corporate tube tube Red Yellow Green Red Grey (mm) (mm) 15 m coil 25 m coil 100 m coil 15 m coil 25 m coil 100 m coil 15 m coil 25 m coil 100 m coil 25m coil 25m coil 4 2,5 PA0104015* PA0104025* PA0104100 PA0304015* PA0304025* PA0304100 PA0204015* PA0204025* PA0204100 PA0804025 PA0604025 5 3,0 PA0105015* PA0105025* PA0105100 PA0305015* PA0305025* PA0305100 PA0205015* PA0205025* PA0205100 - - 6 4,0 PA0106015* PA0106025* PA0106100 PA0306015* PA0306025* PA0306100 PA0206015* PA0206025* PA0206100 PA0806025 PA0606025 8 6,0 PA0108015* PA0108025* PA0108100 PA0308015* PA0308025* PA0308100 PA0208015* PA0208025* PA0208100 PA0808025 PA0608025 10 7,5 PA0110015* PA0110025* PA0110100 PA0310015* PA0310025* PA0310100 PA0210015* PA0210025* PA0210100 - - 12 9,0 PA0112015* PA0112025* PA0112100 PA0312015* PA0312025* PA0312100 PA0212015* PA0212025* PA0212100 - - 14† 11,0 – PA0114025 PA0114100 – PA0314025 PA0314100 – PA0214025 PA0214100 - - N/AL 9.12.001.02 01/98 Metric Tubing and Hose Our policy is one of continuous research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. General Information – Metric Nylon Tubing To DIN Standards 73378 and 74324 Coils are supplied in polythene bags. Those coils marked * can also be supplied in boxes at nominal extra cost, add ‘C’ to end of product number. †Do not conform to above standards. 22 mm and 28 mm O/D tubing conforms to BS 5409 Part 1, Table 2. Other colours can be supplied for orders of sufficient quantity. This standard range of nylon tubing can be supplied in longer lengths to order, provided that a minimum economic production quantity is ordered. All of these coils are supplied in boxes or on drums. This standard range of polyurethane tubing can be supplied in longer lengths to order, provided that a minimum economic production quantity is ordered. O/D I/D Product number tube tube Natural Black Blue Brown (mm) (mm) 15 m coil 25 m coil 100 m coil 15 m coil 25 m coil 100 m coil 15 m coil 25 m coil 100 m coil 100 m coil 4 2,5 PA0004015* PA0004025* PA0004100 PA0704015* PA0704025* PA0704100 PA0504015* PA0504025* PA0504100 PA0404100 5 3,0 PA0005015* PA0005025* PA0005100 PA0705015* PA0705025* PA0705100 PA0505015* PA0505025* PA0505100 PA0405100 6 4,0 PA0006015* PA0006025* PA0006100 PA0706015* PA0706025* PA0706100 PA0506015* PA0506025* PA0506100 PA0406100 8 6,0 PA0008015* PA0008025* PA0008100 PA0708015* PA0708025* PA0708100 PA0508015* PA0508025* PA0508100 - 10 7,5 PA0010015* PA0010025* PA0010100 PA0710015* PA0710025* PA0710100 PA0510015* PA0510025* PA0510100 - 12 9,0 PA0012015* PA0012025* PA0012100 PA0712015* PA0712025* PA0712100 PA0512015* PA0512025* PA0512100 - 14† 11,0 PA0014015 PA0014025 PA0014100 – PA0714025 PA0714100 – PA0514025 PA0514100 - 16 12,0 PA0016015 PA0016025 – – – – – – – - 22† 17,0 PA0022015 PA0022025 – – – – – – – - 28† 22 PA0028015 PA0028025 – – – – – – – - O/D I/D Maximum working pressure (bar) Minimum bend radius (mm) tube (mm) tube (mm) at –40° C to +20° C 4 2,5 28 25 5 3,0 31 25 6 4,0 25 30 8 6 19 50 10 7,5 24 60 12 9,0 18 75 14 11,0 15 80 16 12,0 18 95 22 17,0 15 125 28 22,0 15 160 Working temperature ° C Factor –40° C to +20° C 1,00 +30° C 0,83 +40° C 0,75 +50° C 0,64 +60° C 0,57 +80° C 0,47 Polyurethane Tubing O/D I/D Product number tube tube Natural Black Blue Red Yellow Green (mm) (mm) 25 m coil 100 m coil 25 m coil 100 m coil 25 m coil 100 m coil 25 m coil 100 m coil 25 m coil 100 m coil 4 2,5 PU0004025C PU0004100C PU0704025C PU0704100C PU0504025C PU0504100C PU0104025C PU0104100C PU0304025C PU0304100C 5 3,0 PU0005025C PU0005100C PU0705025C PU0705100C PU0505025C PU0505100C PU0105025C PU0105100C PU0305025C PU0305100C 6 4,0 PU0006025C PU0006100C PU0706025C PU0706100C PU0506025C PU0506100C PU0106025C PU0106100C PU0306025C PU0306100C PU0206100C 8 5,5 PU0008025C PU0008100D PU0708025C PU0708100D PU0508025C PU0508100D PU0108025C PU0108100D PU0308025C PU0308100D PU0208100D 10 7,0 PU0010025C PU0010100D PU0710025C PU0710100D PU0510025C PU0510100D PU0110025C PU0110100D PU0310025C PU0310100D PU0210100D 12 8,0 PU0012025C PU0012100D PU0712025C PU0712100D PU0512025C PU0512100D PU0112025C PU0112100D PU0312025C PU0312100D PU0212100D To calculate working pressures at various temperatures, multiply working pressure at –40°C to +20°C by factor given in table. Maximum continuous working temperature +80°C. Maximum working pressures W orking pressure/temperature conversion factors O/D I/D Maximum Bend Natural tube tube working radius 25m coil (mm) (mm) Pressure (bar) (mm) at 20° C 8 6 10 30 PS0008025 10 8 8 40 PS0010025 12 10 6 60 PS0012025 15 12.5 6 110 PS0015025 Extraflexible Nylon Tubing Working temperature ° C Factor –40° C to +20° C 1,00 +30° C 0,83 +40° C 0,75 +50° C 0,64 +60° C 0,57 To calculate working pressures at various temperatures, multiply working pressure at –40°C to +20°C by factor given in table. Maximum continuous working temperature +60°C. W orking pressure/temperature conversion factors

01/98 N/AL 9.12.001.03 Metric Tubing and Hose Our policy is one of continuous research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. O/D I/D Maximum working pressure (bar) Minimum bend radius (mm) tube (mm) tube (mm) at –40° C to +20° C 4 2,5 10 6 5 3,0 11 7 6 4,0 9 9 8 5,5 9 16 10 7,0 9 17 12 8,0 9 25 To calculate working pressures at various temperatures, multiply working pressure at –40°C to +20°C by factor given in table. Maximum continuous working temperature +60°C. Maximum working pressures W orking pressure/temperature conversion factors Working temperature ° C Factor –40° C to +20° C 1,00 +30° C 0,85 +40° C 0,70 +50° C 0,60 +60° C 0,50 Product Hose Min. Hose Max (bar) ‘O’ clip Number bore bend Ø working product radius O/D pressure number PV2008030 3 25,0 8 10 48 0168 02 PV2010030 5 28,0 10 10 48 0168 03 PV2012030 6,3 31,5 12 10 48 0168 04 PV2014030 8 38,0 13,5 10 48 0168 05 PV2016030 10 48,5 16 10 48 0168 06 PV2019030 12,5 50,5 18,5 9 48 0168 07 PV2027030 20 70,0 27 7 48 0168 11 PV2033030 25 225 33 6 48 0168 15 Product A O/D B Max (bar) Min C D Number* tailpiece working bend hose hose pressure radius I/D O/D 42 0200 00 000 4 19,0 10 28 3 8 42 0210 00 000 5 21,5 10 28 3 8 42 0220 00 000 6 23,0 10 31,5 6,3 12 42 0230 00 000 8 26,0 10 31,5 6,3 12 42 0240 00 000 10 28,0 10 48,5 10 16 42 0250 00 000 12 30,0 10 48,5 10 16 42 0260 00 000 16 34,8 9 50,5 12,5 19 42 0270 00 000 22 42,0 7 70 19 27 42 0280 00 000 28 51,0 6 225 25 33 Polyester reinforced PVC hose 30m coils Pincers DC‘O’ ClipA To Order B Flexible hose assemblies A special pair of pincers, product number 39 0014 00, is available for crimping ‘O’ clips to hose. Instructions 1. Cut off the desired length of hose 2. Insert reusable tailpieces 3. Slip on the ‘O’ clips 4. Clamp tightly with pincers Polyester reinforced PVC hose Operating temperature: –20° C to +70° C. For use at temperatures above +70° C consult our Technical Service. *State the length of hose required when ordering. Maximum length 30m.

N/AL 9.12.001.04 01/98 Metric Tubing and Hose Our policy is one of continuous research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. Product A B C E Min Max (bar) Number O/D A/F bend working tube radius pressure 42 0020 00 000 4 19 * 13 34 69 42 0020 00 250 4 19 250 13 34 69 42 0020 00 300 4 19 300 13 34 69 42 0020 00 350 4 19 350 13 34 69 42 0020 00 400 4 19 400 13 34 69 42 0020 00 500 4 19 500 13 34 69 42 0020 00 600 4 19 600 13 34 69 42 0020 00 750 4 19 750 13 34 69 42 0020 01 000 4 19 100013 34 69 42 0030 00 000 5 21 * 13 34 69 42 0030 00 250 5 21 250 13 34 69 42 0030 00 300 5 21 300 13 34 69 42 0030 00 350 5 21 350 13 34 69 42 0030 00 400 5 21 400 13 34 69 42 0030 00 500 5 21 500 13 34 69 42 0030 00 600 5 21 600 13 34 69 42 0030 00 750 5 21 750 13 34 69 42 0030 01 000 5 21 100013 34 69 42 0040 00 000 6 23 * 14 35 69 42 0040 00 250 6 23 250 14 35 69 42 0040 00 300 6 23 300 14 35 69 42 0040 00 350 6 23 350 14 35 69 42 0040 00 400 6 23 400 14 35 69 42 0040 00 500 6 23 500 14 35 69 42 0040 00 600 6 23 600 14 35 69 42 0040 00 750 6 23 750 14 35 69 42 0040 01 000 6 23 100014 35 69 B BC E A Flexible hose assemblies Metal Braided Rubber Hose Product A B C E Min Max (bar) Number O/D A/F bend working tube radius pressure 42 0050 00 000 8 26 * 17 39 69 42 0050 00 250 8 26 250 17 39 69 42 0050 00 300 8 26 300 17 39 69 42 0050 00 350 8 26 350 17 39 69 42 0050 00 400 8 26 400 17 39 69 42 0050 00 500 8 26 500 17 39 69 42 0050 00 600 8 26 600 17 39 69 42 0050 00 750 8 26 750 17 39 69 42 0050 01 000 8 26 100017 39 69 42 0060 00 000 10 28 * 19 39 69 42 0060 00 250 10 28 250 19 39 69 42 0060 00 300 10 28 300 19 39 69 42 0060 00 350 10 28 350 19 39 69 42 0060 00 400 10 28 400 19 39 69 42 0060 00 500 10 28 500 19 39 69 42 0060 00 600 10 28 600 19 39 69 42 0060 00 750 10 28 750 19 39 69 42 0060 01 000 10 28 100019 39 69 42 0070 00 000 12 30 * 22 51 47 42 0070 00 250 12 30 250 22 51 47 42 0070 00 300 12 30 300 22 51 47 42 0070 00 350 12 30 350 22 51 47 42 0070 00 400 12 30 400 22 51 47 42 0070 00 500 12 30 500 22 51 47 42 0070 00 600 12 30 600 22 51 47 42 0070 00 750 12 30 750 22 51 47 42 0070 01 000 12 30 100022 51 47 Metal braided rubber hoses are suitable for use with petrol, diesel fuel, paraffin and other liquids to pressures stated in the tables below. They are also suitable for use with compressed air up to a maximum working pressure of 10 bar. The maximum working pressures quoted in these tables have been taken under ideal conditions with non-pulsating pressures when used with compression tube fittings, see Section 9.6. W orking temperature range -20°C to +100°C *State length of hose required if ordering non-standard lengths. Minimum length 155mm. When installing a flexible hose the following simple rules should be noted. 1. Flexible hose is weakened when installed in a twisted position. 2. Ample bend radius should be allowed to avoid collapsing the hose. 3. When hose is installed in a flexing application remember that metal end fittings are not part of the flexible portion. 4. Use elbows or adaptors to eliminate excess hose bends. Double wall brazed steel tubing is constructed from copper coated steel strip which is rolled twice around laterally, then furnace brazed to produce a tube of double wall structure, with a clear, scale free coppered bore, a plated external surface and a consistently uniform wall thickness. Double Wall Brazed Steel Tube Product O/D Inside Min Max Number tube diameter bend working 3m straight size radius pressure (bar) (10ft) (min) at 20° C* BU6304003 4 2,6 10 380 BU6306003 6 4,6 13 300 BU6308003 8 6,6 19 250 BU6310003 10 8,6 22 195 BU6312003 12 10,6 44 160 Tolerance on outside diameters is –0,07 mm to +0,05 mm. *Maximum working pressures stated are for tubes of straight length, with non-pulsating pressures when used with Enots compression tube fittings.

01/98 N/AL 9.12.001.05 Metric Tubing and Hose Our policy is one of continuous research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. Product O/D I/D Wall Min Recommended Number tube tube thickness bend safe working 10m coils size size radius pressure (bar) -200° C to +50° C CS6004010 4 2,8 0,6 12 128 CS6005010 5 3,4 0,8 15 138 CS6006010 6 4,4 0,8 19 112 CS6008010 8 6,4 0,8 24 81 CS6010010 10 8,4 0,8 30 64 3m straight CS6012003 12 9,6 1,2 40 81 CS6016003 16 13,6 1,2 48 59 CS6022003 22 19,0 1,5 67 53 CS6028003 28 25,0 1,5 86 41 The following technical information is valid for copper tube when used with compression fittings, see Section 9.5. For further information please consult our Technical Service. Copper Tubing Standard Duty: Annealed Manufactured to BS 2871: Part 2 with dimensions generally to Table 4. Tolerances on O/D are +0,00mm to –0,08mm. The recommended safe working pressures are calculated in accordance with BS1306 with a stress value of 41N/mm2 and minimum tube wall thickness. For safe working pressures at temperatures other than -200° c to +50° C refer to Pressure De-rating Factor table below. Copper Tubing Pressure De-rating Factor For temperatures other than -200°C to +50°C Tube -200° C +50° C +100° C +150° C +175° C to to to to to Annealed 1,0 0,97 0,82 0,63 0,43 Half-hard 1,0 0,95 0,88 0,54 0,29 To calculate the working pressure at temperatures other than –200° C to +50° C multiply the working pressure given in the appropriate table by the factor given in this table.e.g. Safe working pressure of standard duty half-hard copper tube, 8 mm O/D at +120° C = 157 x 0,88 = 138 bar. Product O/D I/D Wall Min Recommended Number tube tube thickness bend safe working 3m straight size size radius pressure (bar) -200° C to +50° C CS7004003 4 2,8 0,6 12 193 CS7005003 5 3,4 0,8 15 208 CS7006003 6 4,0 1,0 19 218 CS7008003 8 6,0 1,0 24 157 CS7010003 10 7,6 1,2 30 150 CS7012003 12 9,6 1,2 40 122 CS7016003 16 13,6 1,2 48 89 CS7022003 22 19,0 1,5 67 81 CS7028003 28 25,0 1,5 86 62 Standard Duty: Half Hard Manufactured to BS 2871: Part 2 with dimensions generally to Table 4. Tolerances on O/D are +0,00mm to –0,08mm. The recommended safe working pressures are calculated in accordance with BS1306 with a stress value of 62N/mm2 and minimum tube wall thickness. For safe working pressures at temperatures other than -200° c to +50° C refer to Pressure De-rating Factor table below. Product Description Number M/3314 Tube cutter

39012061 Replacement blades

Tube Cutter - Plastic Tubing Suitable for providing clean square cuts through 3mm to 19mm plastic tubing. Cutter is provided with Norgren branding in corporate red colour. 79mm 27mm W arning These products are intended for use in industrial compressed air systems only. Do not use these products where pressuresand temperaturescan exceed those listed under ‘Technical Data’. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult Norgren. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products where applicable.