30 AMP Power PCB Relay

FEATURES

Most popular power PCB relay Up to 30 amp switching capacity Gold flashed contacts available Up to 2 horsepower rating UL Class B insulation standard UL Class F insulation available PTRH Available with UL 873 spacing Load Type General Purpose Resistive ( 100,000 cycles) Motor ( 30,000 cycles ) LRA/FLA Voltage

120 VAC

250 VAC

30 VDC

1 Form A

80 A/30 A

96 A/30 A

1 Form B

1 Form C (SPDT)

Initial Contact Resistance Service Life Mechanical Electrical AgCdO (Silver Cadmium Oxide), AgSnOInO (Silver Tin Oxide Indium Oxide) 50 milliohms max @ 0.1A, 6VDC

1 X 107

1 X 105

Operate Time Less than 15 ms. Release Time Insulation Resistance Les than 10 ms. 1,000 megohms min, at 500VDC, 50%RH Dielectric Strength 1500 Vrms, 1 min. between open contacts 1500 Vrms, 1 min. between coil and contacts (2500 Vrms for -1) Shock Resistance 10 g, 11ms, functional; 100 g, destructive Vibration Resistance DA 1.5mm, 10-55 Hz Power Consumption 0.9W, approx. Ambient Temperature Range -55 degrees C to 85 degrees C operating for class B, -40 to 130 degrees C storage Weight 30 grams approx. Sales: Call Toll Free (888)997-3933 Fax (818) 342-5296 email: pickerwest@sbcglobal.net URL: pickercomponents.com

3220 Commander Drive, Suite 102, Carrollton, Texas 75006

Epoxy sealed, immersion cleanable (SPST-NO) (SPST-NC) (locked rotor amps/full load amps) PTRH Rev D 3-25-04 PAGE 1 20 A 20 A 20 A 20 A 20 A 20 A 20 A File # E93379 Now available Lead Free & RoHS Compliant

ohms + 10% Must Operate Voltage Max. (VDC) Must Release Voltage Min. (VDC) Continuous Voltage Max. (VDC) 155 660 2560 10330 3.75 4.50 6.75 9.00 18.00 36.00 82.50 0.5 0.6 0.9 1.2 2.4 4.8 11.0 5.5 6.6 9.9 13.2 26.4 52.8 121.0 Pin Layout Bottom View Overall Dimensions Inches (millimeters) (7.62) .500 (12.7) .700 (17.8) .210 Ref. (5.3) .400 (15.2) .600 .150 (3.8) .550 (14) (8.9) (10.2) .300 .700 (17.8) .350 (19.6) .7701.05 (26.7) 1.25 (31.8) Note 1. Notes: 1. This pin omitted for UL 873 version. 2. Breakable nib may be removed after flux removal. Note 2. Schematic Note 1. Sales: Call Toll Free (888) 997-3933 Fax (818) 342-5296 email: pickerwest@sbcglobal.net URL: pickercomponents.com 3 2 max max max Note: Custom coil voltages within the ranges shown are available on special order. Tolerances + .010 unless otherwise noted Holes for Coil term. .043

ORDERING INFORMATION

Example: PTRH Model -12 Coil Voltage -1C Contact Form 1A, 1B, or 1C S Configuration Nil: Open Frame; S: Sealed plastic case; C: Dust Cover Contact Material Nil: AgCdO; T: AgSnOInO; G: AgCdO+Au F T Spacing Nil: UL 508; -1: UL 873 (Pin # 6 omitted) Insulation Material Nil: UL Class B; F: UL Class F Nil: Standard; -X ROHS Compliant