G2R-1-S_V01 OMRON | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 27
Technical content
238 General-purpose Relays and Power Relays Sockets
General-purpose Relays and Power Relays Sockets Relay Type Track Mount Sockets Back Connecting Sockets Solder terminals PCB terminals G2R-1-S G2R-2-S LY1, LY2 LY3 LY4 MK2 MK3 MY2 MY3 MY4 MY2K MY4(Z)H P2RF-05 P2RF-05-E P2RF-05-S P2RF-08 P2RF-08-E P2RF-08-S PTF08A-E PTF11A PTF14A-E PFO83A-E PF113A-E PYF08A-E PYF08A-N PYF08-S PYF11A PYF14A-E PYF14A-N PYF14S PYF14A-E PYF14A-E P2R-05A P2R-08A PT08 PT11 PT14 PL08 PL11 PY08 PY11 PY14 PY14 P2R-05P P2R-08P PT08-0 PT11-0 PT14-0 PLR08-0 PLE11-0 PY08-02 PY11-02 PY14-02 PY14-02 Relay Type Mounting Track Length Mounting Bracket Track Mount Adaptor Track Mount Socket G7J-(ALL) G7L-1A-T G7L-1A-TJ G7L-1A-B G7L-1A-BJ G7L-2A-T G7L-2A-TJ G7L-2A-B G7L-2A-BJ R99-04-FOR-G5F W bracket R99-07G5D E bracket P7LF-D P7LF-06 P7LF-06 P7LF-06 P7LF-06 PFP-100N PFP-50N 1 meter .5 meter NOTES: 1. -E and -N models are finger-protect construction. Round terminals cannot be used. Use Y-shaped terminals. 2. -S types are screwless terminal styles.
General-purpose Relays and Power Relays Sockets 239 Square Sockets Note: @-E Models are of finger-protect construction. Round terminals cannot be used. Use Y -shaped terminals. Square Sockets Note: @-E and @-N Models are of finger-protect construction. Round terminals cannot be used. Use Y -shaped terminals. Item P2RF (Track-mounting) *see page 246 P2R *see page 248 P7TF (Track- mounting) *see page 249 Screw terminal Solder terminal PCB terminal Screw terminal 5 pins 8 pins --- P2RF-05 Approx. 27 g P2RF-05-E Approx. 38 g P2R-05A Approx. 5 g P2R-05P Approx. 5 g P2R-057P Approx. 5.5 g P7TF-05 Approx. 28 g P2RF-08 Approx. 33 g P2RF-08-E Approx. 38 g P2R-08A Approx. 5 g P2R-08P Approx. 5 g P2R-087P Approx. 5.5 g Item PYF (Track- mounting) *see page 250 PY (back-connecting) *see page 252 PTF (Track- mounting) *see page 253 PT (back-connecting) *see page 255 Screw terminal Solder terminal Wrapping terminal PCB terminal Screw terminal Solder terminal Wrapping terminal PCB terminal 8 pins PYF08A Approx. 32 g PYF08A-E PYF08A-N PY08 Approx. 8 g PY08-Y1 PY08-Y3 PYQ08QN Approx. 12 g PYQ08QN-Y1 PYQ08QN2-Y1 PYQ08QN2 PY08-02 Approx. 7.2 g PTF08A Approx. 39 g PTF08A-E PT08 Approx. 11 g PT08QN Approx. 10.4 g PT08-0 Approx. 8 g
240 General-purpose Relays and Power Relays Sockets
Note: @-E and @-N Models are of finger-protect construction. Round terminals cannot be used. Use Y -shaped terminals. Item PYF (Track- mounting) *see page 250 PY (back-connecting) *see page 252 PTF (Track- mounting) *see page 253 PT (back-connecting) *see page 255 Screw terminal Solder terminal Wrapping terminal PCB terminal Screw terminal Solder terminal Wrapping terminal PCB terminal 11 pins 14 pins PYF11A Approx. 46 g PY11 Approx. 9 g PY11-Y1 PY11QN PY11QN2 PY11QN-Y1 PY11QN2-Y1 PY11-02 PTF11A Approx. 50 g PT11 Approx. 13 g PT11QN PT11-0 Approx. 12.2 g PYF14A Approx. 49 g PYF14A-E PYF14T Approx. 53 g PYF14A-N PY14 Approx. 10 g PY14-Y1 PY14-Y2 PY14QN PY14QN2 Approx. 14 g PY14QN-Y1 PY14QN2-Y1 PY14QN-Y2 PY14QN2-Y2 PY14-02 PTF14A Approx. 60 g PTF14A-E PT14 Approx. 17 g PT14QN Approx. 20 g PT14-0 Approx. 16.2 g Item P7LF (Track-mounting) *see page 256 Screw terminal 6 pins P7LF-06 Approx. 60 g Item P7S *see page 257 Screw terminal (Track-mounting) Solder terminal PCB terminal 14 pins P7S-14F Approx. 75 g P7S-14A Approx. 10 g P7S-14P Approx. 10 g
General-purpose Relays and Power Relays Sockets 241 Round Sockets Note: This model succeeds the P3G-11 for which production was stopped in March 1991. Item PF (Track- mounting) *see page 258 P2CF (Track- mounting) PFA (Track- mounting) P3G (Track- mounting) PL (back-connecting) *see page 261 Solder terminal Wrapping terminal PCB terminal 8 pins 11 pins PF083A Approx. 34 g PF083A-E PF085A Approx. 40 g P2CF-08 Approx. 55 g 8PFA Approx. 57 g 8PFA1 Approx. 66 g P3G-08 Approx. 40 g PL08 Approx. 14 g PL08-Q Approx. 15 g PLE08-0 Approx. 10.6 g PF113A Approx. 47 g PF113A-E P2CF-11 Approx. 70 g 11PFA Approx. 74 g P3GA-11 (see note) Approx. 47 g PL11 Approx. 15 g PL11-Q Approx. 18.5 g PLE11-0 Approx. 10.8 g 14PFA Approx. 104 g PL15 Approx. 28 g PF202 Approx. 170 g PL20 Approx. 17 g
242 General-purpose Relays and Power Relays Sockets
■Hold-down Clips For Square Sockets For Round Sockets Note: There are 2 pieces per set. 5 max. PYC-A1 (see note) 36.3 4.5 1.24.5 5 max. PYC-A2 (see note) 42.8 4.5 1.24.5 29 max. PYC-P 36.53.3 PYC-E1 (see note) 36.3 5.75 4.25 4.5+0.1 PYC-P2 PYC-S 2.5 PYC-1 9.4 52 58.2 Approx. 3 PYC-2 28.8 PYC-3 29.5 44.5 PYC-5 3.7 41.7 PYC 3.7 34.5 60.8 62 4.6 4.5 PFC-A1 (see note) 73.3 74.5 4.6 4.5 PEC-A6 (see note) 94 95.2 4.5 4.6 PEC-A7 (see note) 56.6 7.6 PLC (see note) 56.3 PLC-1 (see note) 69.2 65.7 PLC-7 (see note) 90.2 86.7 PLC-8 (see note) 66.2 PLC-10 (see note) 64.3 PLC-12 (see note)
General-purpose Relays and Power Relays Sockets 243 ■Models Used with Sockets ■Models Used with Hold-down Clips Square Sockets Note: Pin numbers 08, 11, or 14 apply to @. Round Sockets Note: 1. 8PFA(I), 11PFA, and 14PFA has hooks that can hold a Relay. 2. PL15, PL20, PF202, and Sockets that are not listed in the above table should be mounted to a panel after opening mounting holes on the panel. 3. A Hold-down Clip for PF085A is sold together with Relays that can be used with PF085A. Group Model Pin No. Socket Front-connecting Back-connecting MY(K) MY2 8 PYF PY MY3 11 MY4, MY2K 14 LY LY 1 , LY 2 8 P T F P T LY 3 1 1 LY 4 1 4 G2A(K) G2A, G2A-434, G2AK 14 PYF PY MK(K) MK2P 8 PF083A(-E) PL MK3P , MK2KP 11 PF113A(-E) MM(K) MM2(X)P 8 8PFA MM3P , MM2(X)KP 11 PFA MM3XP , MM3(X)KP , MM4(X)P , MM4(X)KP G4Q --- 8 8PFA1 G7L G7L- @A-T(J) 6 P7LF --- Item PYF @A(-E, -N), PTF@A(-E) PY @(QN), PT@(QN) PY @-02, PT@-0 MY( ), MY( )N, MY( )N-D2, MY( )N-CR, MY2K, L Y( ), L Y( )N, G3H, G3F , G3FD, G3FM PYC-A1 PYC-P , PYC-S PYC-P MY4IN PYC-P , PYC-P2 PYC-P , PYC-P2 MY2IN PYC-E1 PYC-P2 PYC-P2 L Y( )-CR Y92H-3 PYC-1 PYC-1 G2A(K) Series PYC-A2 PYC-2, PYC-3, PYC-5 PYC-3, PYC-5 Item PF083A, PF113A PL08(-Q), PL11(-Q) PLE08-0, PLE11-0 MK2P Series, MK2KP , MK3P@ (-US), G3B PFC-A1 PLC PLC-10 MK3ZP , MK3LP PLC-1 MYA-NA1, -NB1, MYA-LA1, -LB1, MYA-NA2, -NB2 MYA-LA2, -LB2 PFC-A6 PLC-7 --- MYA-LA12, -LB12 PFC-A7 PLC-8 ---
244 General-purpose Relays and Power Relays Sockets
■Socket Performance Characteristics Item Carry current Dielectric strength Insulation resistance (see note 2) P2RF-05(-E) 10 A Between contacts of same polarity: 1,000 VAC for 1 min Between coil and contact: 4,000 VAC for 1 min 1,000 M Ω min. P2RF-08(-E) 5 A Between contact of different polarity: 3,000 VAC for 1 min Between contacts of same polarity: 1,000 VAC for 1 min Between coil and contact: 4,000 VAC for 1 min 1,000 M Ω min. P2R-057P 10 A Between contacts of same polarity: 1,000 VAC for 1 min Between coil and contact: 5,000 VAC for 1 min 1,000 M Ω min. P2R-087P 5 A Between contact of different polarity: 3,000 VAC for 1 min Between contacts of same polarity: 1,000 VAC for 1 min Between coil and contact: 5,000 VAC for 1 min 1,000 M Ω min. P2R-05A 10 A Between contacts of same polarity: 1,000 VAC for 1 min Between ground terminal and other termi- nals: 1,500 VAC for 1 min Between coil and contact: 4,000 VAC for 1 min 1,000 M Ω min. P2R-08A 5 A Between contact of different polarity: 3,000 VAC for 1 min Between contacts of same polarity: 1,000 VAC for 1 min Between ground terminal and other termi- nals: 1,500 VAC for 1 min Between coil and contact: 4,000 VAC for 1 min 1,000 M Ω min. P7TF-05 5 A Between terminals: 2,000 VAC for 1 min 100 M Ω min. PYF08A-E 7 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. PYF08A-N 7 A (see note 3) Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. PYF11A 5 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. PYF14A-E 5 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. PYF14A-N 5 A (see note 3) Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. PY08(-Y1) 7 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PY08QN(-Y1) 7 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PY08-02 7 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PY11(-Y1) 5 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PY11QN(-Y1) 5 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PY11-02 5 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PY14(-Y1) 3 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PY14QN(-Y1) 3 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PY14-02 3 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PTF@@A 10 A Between terminals: 2,000 VAC for 1 min 100 M Ω min. PT@@ 10 A Between terminals: 2,000 VAC for 1 min 100 M Ω min. PT@@QN 10 A Between terminals: 2,000 VAC for 1 min 100 M Ω min. PT@@-0 10 A Between terminals: 2,000 VAC for 1 min 100 M Ω min.
General-purpose Relays and Power Relays Sockets 245 Note: 1. The values given above are initial values. 2. The values for insulation resistance were measured at 500 V at the same place as the dielectric strength. 3. The maximum operating ambient temperature for the PYF08A-N and PYF14A-N is 55 °C. When using the PYF08A-N or PYF14A-N at an operating ambient temperature exceeding 40°C, reduce the current to 60%. ■Track and Accessories P7LF-06 30 A Between contact of different polarity: 2,000 VAC for 1 min Between contacts of same polarity: 2,000 VAC for 1 min Between coil and contact: 4,000 VAC for 1 min 1,000 M Ω min. PF@@@A 5 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. P2CF 5 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. P3G(A) 6 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. 8PFA(1) 10 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. 11PFA(1) 10 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. PL@@(-Q) 10 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. PLE@@-0 10 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. P6D-04P 5 A Between contacts of same polarity: 1,000 VAC for 1 min Between coil and contact: 3,000 VAC for 1 min 100 M Ω min. P7S-14@ 6 A Between terminals: 2,500 VAC for 1 min Between ground terminal and other termi- nals (P7S-14A): 2,000 VAC for 1 min 100 M Ω min. Item Carry current Dielectric strength Insulation resistance (see note 2) 4.5 15 25 2510 25 1000 2510 15 29.2 1.5 27 24 35±0.3 M4 x 8 pan head screw M4 spring washer 11.5 6.2 1.8 35.5 1.8 1.3 4.8 44.3 16.5 4.5 15 25 2510 1000 (500) * 2510 15 (5) Mounting Track PFP-100N PFP-50N Note: The figure in the parentheses is for PFP-50N. 35±0.3 7.3±0.15 27±0.15 Mounting Track PFP-100N2 End Plate PFP-M Spacer PFP-S 35.3 34.8
246 General-purpose Relays and Power Relays Sockets
Note: All units are in millimeters unless otherwise indicated. ■P2RF Dimensions Terminal arrangement/Internal connections (top view) Mounting holes (top view) P2RF-05 (One pole) Five, M3.5 x 8 71.5 max. 19.5 max. 54 max. 30 max. 4 dia. 4.2-dia. holes M3 (M3 x 16) or 3.5-dia. hole Note: Track-mounting is also possible. P2RF-05-E (One pole) M3.5 screw 85.5 max. 3.5-dia. holes 59 max. 48 max. * When mounted on H3RN-1@. 61 max. (80.9 max.)* Note: Figures in pa- rentheses are DIN standard numbers. Note: Track-mounting is also possible. M3 or 3.5-dia. holes 3.2-dia. holes P2RF-08 (Two poles) 71.5 max. 19.5 max. 30 max. 54 max. 4 dia.Eight, M3.5 x 8 Note: Track-mounting is also possible. 4.2-dia. holes M3 (M3 x 16) or 3.5-dia. hole
General-purpose Relays and Power Relays Sockets 247 Note: When indicator modules with an I/O SSR are used, the No. 1 pin becomes positive. Dimensions Terminal arrangement/ Internal connections (top view) Mounting holes (top view) P2RF-08-E (Two poles) M3 screw 3.5-dia. holes 85.5 max. 61 max. 63 max. (84.9 max.)* 48 max. 3 dia. * When mounted on H3RN-2@. Note: Figures in paren- theses are DIN standard num- bers. Note: Track-mounting is also possible. M3 or 3.5-dia. holes 3.2-dia. holes
248 General-purpose Relays and Power Relays Sockets
■P2R Note: When indicator modules with an I/O SSR ar e used, the No. 1 pin becomes positive. Dimensions Terminal arrangement/ Internal connections (bottom view) Mounting holes (bottom view) 14.5 max. 35.5 max. 36.5 max. P2R-05P (One pole) Five, 1.6-dia. holes 14.5 max. 35.5 max. 36.5 max. P2R-08P (Two poles) Eight, 1.3-dia. holes P2R-057P (One pole) 14 max. 37 max. 41 max. Five, 1.6-dia. holes P2R-087P (Two poles) 37 max. 14 max. 41 max. Eight, 1.3-dia. holes
General-purpose Relays and Power Relays Sockets 249 ■P2R/P7TF Note: When indicator modules with an I/O SSR are used, the No. 1 pin becomes positive. Dimensions Terminal arrangement/ Internal connections Mounting holes P2R-05A (One pole) 14.5 max. 35.5 max. Five, 3 x 1.8-dia. holes 36.5 max. (Bottom view) Use panel with thickness of 1.6 to 2.0 mm. P2R-08A (Two poles) 14.5 max. 35.5 max. Eight, 3 x 1.2-dia. holes 36.5 max. (Bottom view) P7TF-05 19 max. 71.5 max. Screw with square washer 59 max. (Top view) (−)(+) Two, 3.0 dia. (Top view) Note: Track-mounting is also possible.
250 General-purpose Relays and Power Relays Sockets
■PYF Dimensions Dimensions Terminal arrangement/ Internal connections (top view) Mounting holes (top view) Eight, M3 x 8 sems screws PYF08A Two, 4.2 x 5 mounting holes 6 72 max. 23 max. 3.4 16.5 35.4 30 max. Two, M3, M4, or 4.5-dia. holes 15±0.2 59±0.3 Note: Track-mounting is also possible. Two, 4.2 x 5 mounting holes 6 Eight, M3 x 8 sems 72 max. max. 3.4 35.4 16.5 31 max. PYF08A-E Two, M3 or M4 (or 4.5-dia.) holes 59±0.3 15±0.1 Note: Track-mounting is also possible. 22 max. 67 max. PYF-08A-N 30 max. PYF08A-N 8 5 12 9 14 14 13 41 11 A2 A2 A1 18.7 3.0 dia. 3.5 dia. or M3 Note: Track-mounting is also possible. Refer to page 245 for Mounting Tracks. PYF11A Two, 4.2 x 5 mounting holes Eleven, M3 x 8 sems 72 max. 29.5 max. 30 max. Two, M3 or M4 (or 4.5-dia.) holes Note: Track-mounting is also possible.
General-purpose Relays and Power Relays Sockets 251 Dimensions Terminal arrangement/ Internal connections (top view) Mounting holes (top view) PYF14A Two, 4.2 x 5 mounting holes Fourteen, M3 x 8 sems 72 max. 29.5 max. 30 max. 3 2 1 8765 10 91112 1314 Two, M3 or M4 (or 4.5-dia.) holes Note: Track-mounting is also possible. PYF14A-E Two, 4.2 x 5 mounting holes Fourteen, M3 x 8 sems 29.5 max. 31 max. 72 max. 30 max. 514 119 67 max. PYF-14A-N 29.5 max. PYF14A-N 4 3 2 1 8 7 6 5 12 11 10 9 14 14 13 42 32 22 12 44 34 24 14 41 31 21 11 A2 A2 A1 Two, 4.5 dia. or M4 Note: Track-mounting is also possible. Refer to page 245 for Mounting Tracks. PYF14T Two, 4.2 x 5 dia. mounting holes Fourteen, M3 x 8 sems 33 max. 70 max. 321 8765 10 91112 4 1314 Note: Track-mounting is also possible. Two, M4
252 General-purpose Relays and Power Relays Sockets
■PY Dimensions Dimensions Terminal arrangement/ Internal connections (bottom view) Mounting holes PY08 PY08-Y1 PY08-Y3 Eight, 3-dia. x 1.2 ellipses 2.7 7.7 max. 20 max. 25.5 max. 29.5 max. 2.6 max. Note: PY08-Y1 includes the part outlined by the dashed lines above. +0.2 13.2 5.8 +0.2 6.4 25.8 4.1 21.4 12.656.35 Eight, 1.3-dia. holes4.2 PY08QN PY08QN2 PY08QN-Y1 PY08QN2-Y1 * 2.7 max. (20) 41.5 max. (36.5 max.) 29.5 max. max. max. Note: 1. PY08QN(2)-Y1 includes the part outlined by the dashed lines above. 2 The fi gures in the parentheses are for PY08QN2. PY08-02 0.3 2.7 4.3 16.5 max. 1.0 25.5 max. 29.5 max. 222 max. Note: PY08-Y1 includes the part outlined by the dashed lines above. PY11 PY11-Y1 Eleven, 3-dia. x 1.2 ellipses Note: PY11-Y1 includes the part outlined by the dashed lines above. 25.5 max. 29.5 max. 24 max.20 max. 42 max. Eleven, 1.3-dia. holes PY11QN PY11QN2 PY11QN-Y1 PY11QN2-Y1 * 42 max. 41.5 max. (36.5 max.)** 29.5 max. max. max. Note: 1. PY11QN(2)-Y1 includes the part outlined by the dashed lines above. 2 The figures in the parentheses are for PY11QN2 (-Y1). PY11-02 16.5 max. 25.5 max. 29.5 max. max.
General-purpose Relays and Power Relays Sockets 253 Note: 1. Use a panel with a thickness of 1 to 2 mm when mounting a Socket on it. 2. The PY14-Y1 and the PY14QN-Y1 can be used with MY4-series models and the MY2K. ■PTF Dimensions Dimensions Terminal arrangement/ Internal connections (bottom view) Mounting holes PY14 PY14-Y1 (l=42 max.) PY14-Y3 (l=60 max.) Fourteen, 3-dia. x 1.2 ellipses Note: PY14-Y1 includes the part outlined by the dashed lines above. 25.5 max. 29.5 max. 24 max.20 max. l Fourteen, 1.3-dia. holes PY14QN, PY14QN2 PY14QN-Y1 (l=42 max.) PY14QN2-Y1 (l=42 max.) PY14QN-Y2 (l=49 max.) PY14QN2-Y2 (l=49 max.) PY14QN-Y3 (l=60 max.) PY14QN2-Y3 (l=60 max.) 41.5 max. (36.5 max.)** 29.5 max. max. max. Note: 1. PY11QN(2)-Y1 includes the part outlined by the dashed lines above. 2 The figures in the parentheses are for PY11QN2 (-Y1). PY14-02 16.5 max. 25.5 max. 29.5 max. max. Dimensions Terminal arrangement/ Internal connections (top view) Mounting holes (top view) PTF08A Two, 4.5 x 6 mounting holes Eight, 3.5M x 8 screw 78.5 max. 28.5 max. 35.4 max. 7 3.4 Two, M4 or 4.5-dia. holes Note: Track-mounting is avail- able. See page 245. ±0.3 27.5±0.2
254 General-purpose Relays and Power Relays Sockets
Note: If PTF08A and PT08 are used in combination with L Y1 with a total current flow of 10 A minimum, terminals 1 and 2, 3 and 4, 5 and 6 respec- tively should be short-circuited. Dimensions Terminal arrangement/ Internal connections (top view) Mounting holes (top view) Two, 4.5 x 6 mounting holes 7 Eight, M3.5 x 8 sems 78.5 max. 28.5 max. 3.4 35.4 32.65 max. PTF08A-E Two, M4 or two, 4.5-dia. holes 68±0.3 19±0.2 Note: Track-mounting is avail- able. See page 245. PTF11A Two, 4.5 x 6 mounting holes Eleven, 3.5M x 8 screw 78.5 max. 37 max. 30 max. Two, M4 or 4.5-dia. holes Note: Track-mounting is avail- able. See page 245. PTF14A Two, 4.5 x 6 mounting holes Fourteen, 3.5M x 8 screw 78.5 max. 45.5 max. 30 max. Two, M4 or 4.5-dia. holes Note: Track-mounting is avail- able. See page 245. PTF14A-E Two, 4.5 x 6 mounting holes Fourteen, 3.5M x 8 screw 78.5 max. 45.5 max. max.
General-purpose Relays and Power Relays Sockets 255 ■PT Dimensions Dimensions Terminal arrangement/ Internal connections (bottom view) Mounting holes 2.7 25.5 max. 29.5 max. PT08 0.3 Eight, 1.7-dia. x 3.5 ellipses PT08QN 1.5 x 10 2.7 9 20 1.5 max. 1.0 25.5 max. 29.5 max. 2.5 35 max. 20.5 max. +0.2 025.8 +0.2 021.4 PT08-0 0.3 2 5* 1 4.3 18 max. 22 max. 6.5 29.5 max. *Keep a proper distance between the Socket and PCB patterns. 5.35 6.5 15.6 4.6 12.456.45 3 Eight, 2.5-dia. holes The tolerance is ±0.1. PT11 PT11QN max. 29.5 max. Eleven, 1.7-dia. x 3.5 holes 35 max. 20.5 max. 32 max. 29.5 max. 1.5 x 10 PT11-0 18 max. 29.5 max. 32 max. *Keep a proper distance between the Socket and PCB patterns. Eleven, 2.5-dia. holes The tolerance is ±0.1.
256 General-purpose Relays and Power Relays Sockets
Note: Use a panel with a thickness of 1 to 2 mm when mounting a Socket on it. ■P7LF Dimensions Dimensions Terminal arrangement/ Internal connections (bottom view) Mounting holes PT14QNPT14 42.5 max. Fourteen, 1.7-dia. x 3.5 holes 35 max. 20.5 max. 1.5 x 1.0 26.5 max. 29.5 max. 42.5 max. 26.5 max. 29.5 max. PT14-0 17.5 max. 42.5 max. *Keep a proper distance between the Socket and PCB patterns. 26.5 max. 29.5 max. Fourteen, 2.5-dia. holes The tolerance is ±0.1. Dimensions Terminal arrangement/ Internal connections (top view) Mounting holes P7LF-06 Two, M3.5 (coil side) Four, M4 (contact side) 51.5 max. 55.5 max. 46 max. 0 1 2 46 8 Two, M4 or 4.5-dia. holes
General-purpose Relays and Power Relays Sockets 257 ■P7S Dimensions Dimensions Terminal arrangement/ Internal connections Mounting holes P7S-14F 40 max. Fourteen, M3.0 47 max. 90.5 max. 40 max. (top view) Two, M3.5 or 4.0-dia. holes P7S-14A 61.5 max. 33 max. max. G7S-4A2B G7S-3A3B (bottom view) P7S-14P 61.5 max. 29 max. 23 max. Two, 6.5 dia. × 7.9 23 max. G7S-4A2B G7S-3A3B (bottom view) Two, 3.6 dia. Fourteen, 1.8 dia.
258 General-purpose Relays and Power Relays Sockets
■PF Dimensions Dimensions Terminal arrangement/ Internal connections (top view) Mounting holes PF083A Eight, M3.5 x 7 sems screws 52 max. 4 33 41 max. Two 4.2-dia. holes 35.4 21 max. 3.5 Note: Track-mounting is avail- able. See page 245. Two, M4 or 4.5-dia. holes 33±0.2 PF083A-E Eight, M3.5 x 7 sems 7 Two, 4.2-dia. holes 52 max. 41 max. 35.4 3.5 2 21 max. Two, M4 or two, 4.5-dia. holes 33±0.2 PF085A Eight, M3.5 x 7 sems screws 58 max. Two 4.5-dia. holes 33±0.2 35.4 23.5 21.6 max. 1.1 40 max. Note: Track-mounting is avail- able. See page 245. Two, M4 or 4.5-dia. holes 33±0.2 PF113A Eight, M3.5 x 7 sems screws 52 max. Two 4.2-dia. holes 21 max.41 max. Note: Track-mounting is avail- able. See page 245. Two, M4 or 4.5-dia. holes PF113A-E Eight, M3.5 x 7 sems Two, 4.2-dia. holes 52 max. 41 max. 21 max.
General-purpose Relays and Power Relays Sockets 259 Note: The key groove of PF083A and PF113A (used with MK Relays) are on the upside. ■P2CF/PFA Dimensions Dimensions Terminal arrangement/ Internal connections (top view) Mounting holes PF202 101 max. Two, 4.5-dia. holes Two, M3 Relay mounting screws 33 max. 71 max. Two, M4 or 4.5-dia. holes Dimensions Terminal arrangement/ Internal connections (top view) Mounting holes P2CF-08 Eight, M3.5 x 7.5 sems screws 70 max. Two, 4.5-dia. holes 31.2 max. 50 max. Note: Track-mounting is avail- able. See page 245. Two, M4 or 4.5-dia. holes P2CF-11 Eleven, M3.5 x 7.5 sems screws 70 max. Two, 4.5-dia. holes 31.2 max. 50 max. Two, 4.5-dia. mounting holes Note: Track-mounting is avail- able. See page 245.
260 General-purpose Relays and Power Relays Sockets
■PFA/P3G/P3GA Dimensions Dimensions Terminal arrangement/ Internal connections (top view) Mounting holes 8PFA Eight, M3.5 x 7 sems screws 81 max. Two, 4.5-dia. holes 24 max. 118 max. 51 max. Two, 4.5-dia. mounting holes Note: Track-mounting is avail- able. See page 245. 8PFA1 Eight, M3.5 x 7 sems screws 93 max. Two, 4.5-dia. holes 24 max. 130 max. 51 max. Dimensions Terminal arrangement/ Internal connections (top view) Mounting holes 11PFA Eleven, M3.5 x 7 sems screws 81 max. Two, 4.5-dia. holes 33.5 max. 118 max. 51 max. Note: Track-mounting is avail- able. See page 245. Two, M4 or 4.5-dia. holes 14PFA Fourteen, M3.5 x 7 sems screws 81 max. Two, 4.5-dia. holes 33.5 max. 118 max. 72 max. Note: Track-mounting is avail- able. See page 245. Two, M4 or 4.5-dia. holes
General-purpose Relays and Power Relays Sockets 261 ■PL Dimensions Note: When mounting, pay due attention to the direction of the key groove of applicable Relays. Dimensions Terminal arrangement/ Internal connections (top view) Mounting holes --- --- P3G-08 27 dia. P3GA-11 27 dia. Dimensions Terminal arrangement/ Internal connections (bottom view) Mounting holes PL08 3.5 51 max. 40 max. 4 1 30 dia. max. 0.6t x 1.3 74 or 8640±0.3 Two, 3.5-dia. or two, M3 Relay-mounting holes Two, 3.5-dia. or two, M3 Socket-mounting holes 31-dia. hole PL08-Q 50.5 max. 40 3.5 max. 30 dia. Two, 2-dia. holes Approx. 20.5 3.9 Two, 3.5-dia. or two, M3 Relay-mounting holes Two, 3.5-dia. or two, M3 Socket-mounting holes 31-dia. hole 40 ±0.3 PLE08-0 29 dia.±0.3 14 5 0.3t 21.5 max. Two, 3.5-dia. Hold-down Clip-mounting holes40±0.3 27.7±0.5 Eight, 2.5-dia. holes
262 General-purpose Relays and Power Relays Sockets
■PL Dimensions Dimensions Terminal arrangement/ Internal connections (bottom view) Mounting holes PL11 51 max. Approx. 20.5 max. Two, 2-dia. holes 30 dia. 35 max. Two, 3.5-dia. or two, M3-mounting holes for applicable models Two, 3.5-dia. or two, M3 Socket-mounting holes 31-dia. hole L=40 mm MK3P , MK2KP , MK3ZP , MK3LP L=74 mm MM3P , MM2(X)KP PL11-Q 51 max. 35 max. 35 max. PLE11-0 29±0.1 dia. 22 max. Eleven, 2.5-dia. holes Two, 3.5-dia. Hold-down Clip-mounting holes L= Distance between mounting holes required for MK Eleven, 2.5-dia. holes MK3P MK2KP PL15 66 max. 22 max. Two, 2-dia. holes 41 max. 45 max. Two, 3.5-dia. or two, M3-mounting holes for applicable models Two, 3.5-dia. or two, M3 Socket-mounting holes 42-dia. hole MK3XP , MM4(X)P , MM3(X)KP , MM4(X)KP PL20 46.5 max. 36.5 max. 23 max. Two, 2-dia. holes Two, 3.5-dia. holes31 max. Two, 4.5-dia. Relay-mounting holes Two, Socket-mounting holes 33-dia. hole Note: Mounting hole preparation not required for LDNP . ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
- Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
- Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations.
- Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2010.1 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2010 All Right Reserved.
J35I-E-01 01/07 Note: Specifications are subject to change. © 2010 Omron Electronics LLC OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 www.omron247.com OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE OMRON ELECTRONICS MEXICO SA DE CV • HEAD OFFICE OMRON ARGENTINA • SALES OFFICE Cono Sur • 54.11.4783.5300 OMRON CHILE • SALES OFFICE Santiago • 56.9.9917.3920 OTHER OMRON LATIN AMERICA SALES 54.11.4783.5300