Features
■Fully welded metal measuring cell ■Pressure range 0…40 bar rel. ■18…33 V DC ■NO/NC contact, 2 × PNP/NPN outputs, IO- Link ■Process connection 1/4"-18 NPT male thread ■Plug-in device, M12 × 1 Wiring diagram Functional principle The pressure sensors in the PT…‐2000 product series operate with a fully welded metal measuring cell in various pressure ranges of up to -1…1000 bar in 2-, 3- or even 4-wire technology. Depending on the sensor variant, the processed signal is available as an analog output signal (4…20 mA, 0…
10 V, 0…5 V, 1…6 V, ratiometric) or as a
digital IO-Link process parameter. The IO-Link sensor variants also have two independently configurable switching outputs. In addition to the standard variants, there are special sensors for uses such as ATEX areas or for oxygen applications. A wide range of process connections and electrical connections offer a high degree of flexibility in a wide range of applications.
TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 2|5 PT40R-2003-IOL-H1141 | 11/08/2023 00-17 | technical changes reserved Technical data Switching point distance ≥ 0.5 % Switch point: (Min. + 0.005 × range)…100 % of full scale Release point(s) Min. up to (SP - 0.005 × range) Switching cycles ≥ 100 mil. Resolution <± 0.1 % FS Accuracy LHR ±0.3 % FS (typical; max. ±0.5 % FS) IO-Link IO-Link specification V 1.1 Transmission physics corresponds to 3-wire physics (PHY2) Frame type 2.2 Transmission rate COM 2/38.4 kbps Programming FDT/DTM Programming options Offset; filter; switching points; hysteresis/ filter function, NC/NO; min./max. pressure values, pressure peak counter; operating hours counter Mechanical data Housing material Stainless-steel/Plastic, 1.4404 (AISI 316L)/polyarylamide 50 % GF UL 94 V-0 Process connection 1/4'' NPT-18 male thread Pressure connection material Stainless steel 1.4404 (AISI 316L) Pressure transducer material Stainless steel 1.4016 (AISI 430) Wrench size pressure connection / coupling nut Max. tightening torque of housing nut 20 Nm Electrical connection Connector, M12 × 1 Protection class IP67 Environmental conditions Ambient temperature -30…+85 °C Storage temperature -50…+100 °C Shock resistance 100 g, 11 ms, half sinusoidal curve, all 6 directions, free fall from 1 m onto concrete (6x) acc. to IEC 68-2-27 Vibration resistance 20 g, 15…2000 Hz, 15…25 Hz with amplitude ± 15 mm, 1 octave/minute in all 3 directions, 50 continuous loads Tests/approvals UL registration number E302799 Reference conditions acc. to IEC 61298-1 Temperature 15…+25 °C
TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 3|5 PT40R-2003-IOL-H1141 | 11/08/2023 00-17 | technical changes reserved Technical data Atmospheric pressure 860…1060 hPa abs. Humidity 45…75 % rel. Auxiliary power 24 VDC Temperature behaviour MTTF 1200 years acc. to SN 29500 (Ed. 99) 40 Technical data Type PT40R-2003-IOL-H1141 ID 100017821 Pressure range Pressure type Relative pressure Pressure range 0…40 bar 0…580.15 psi 0…4 MPa Admissible overpressure ≤ 120 bar Burst pressure ≥ 240 bar Response time < 2 ms, typ. 1 ms Long-term stability 0.25 % FS, according to IEC EN 60770-1 Power supply Operating voltage 18…33 VDC In IO-Link mode 9…33 VDC In SIO mode Short-circuit/reverse polarity protection yes / yes Protection type and class IP67 / III Insulation voltage 750 VDC Outputs Output 1 Switching output or IO-Link mode Output 2 Switching output Switching output Communication protocol IO-Link Output function NO/NC, PNP/NPN Switching current ≤ 100 mA Switching frequency ≤ 100 Hz Switching point distance ≥ 0.5 % Switch point: (Min. + 0.005 × range)…100 % of full scale Release point(s) Min. up to (SP - 0.005 × range)
TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 4|5 PT40R-2003-IOL-H1141 | 11/08/2023 00-17 | technical changes reserved Technical data Switching cycles ≥ 100 mil. Switch point SP1 Factory setting: 50 % of measuring range end value Release point rP1 Factory setting: 25 % of measuring range end value Switching point SP2 Factory setting: 60 % of measuring range end value Release point rP2 Factory setting: 30 % of measuring range end value Resolution <± 0.1 % FS Accuracy LHR ±0.3 % FS (typical; max. ±0.5 % FS) IO-Link IO-Link specification V 1.1 Programming FDT/DTM Transmission physics corresponds to 3-wire physics (PHY2) Transmission rate COM 2/38.4 kbps Frame type 2.2 Temperature behaviour Medium temperature -40…+135 °C Temperature coefficient ± 0.2 % of full scale/10 K Environmental conditions Ambient temperature -30…+85 °C Storage temperature -50…+100 °C Vibration resistance 20 g, 15…2000 Hz, 15…25 Hz with amplitude ± 15 mm, 1 octave/minute in all 3 directions, 50 continuous loads, acc. to IEC 68-2-6 Shock resistance 100 g, 11 ms, half sinusoidal curve, all 6 directions, free fall from 1 m onto concrete (6x) acc. to IEC 68-2-27 Mechanical data Housing material Stainless-steel/Plastic, 1.4404 (AISI 316L)/polyarylamide 50 % GF UL 94 V-0 Pressure connection material Stainless steel 1.4404 (AISI 316L) Pressure transducer material Stainless steel 1.4016 (AISI 430) Process connection 1/4'' NPT-18 male thread Wrench size pressure connection / coupling nut Electrical connection Connector, M12 × 1 Max. tightening torque of housing nut 20 Nm
TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 5|5 PT40R-2003-IOL-H1141 | 11/08/2023 00-17 | technical changes reserved Technical data Reference conditions acc. to IEC 61298-1 Temperature 15…+25 °C Atmospheric pressure 860…1060 hPa abs. Humidity 45…75 % rel. Auxiliary power 24 VDC Programming options Offset; filter; switching points; hysteresis/ filter function, NC/NO; min./max. pressure values, pressure peak counter; operating hours counter Tests/approvals Approvals cULus UL registration number E302799 MTTF 1200 years acc. to SN 29500 (Ed. 99) 40