100046100 TURCK | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 5

Technical content

Features

■Fully welded metal measuring cell ■Pressure range 0…14500 psi rel. ■10…30 VDC ■Analog output 4…20 mA ■Process connection 1/4"-18 NPT male thread ■Plug-in device, M12 × 1 ■ATEX, IECEx ■Category II 1/2 GD, Ex zone 0 Wiring diagram Functional principle The pressure sensors in the PT…‐2000 product series operate with a fully welded metal measuring cell in various pressure ranges of up to -1…1000 bar in 2-, 3- or even 4-wire technology. Depending on the sensor variant, the processed signal is available as an analog output signal (4…20 mA, 0…

10 V, 0…5 V, 1…6 V, ratiometric) or as a

digital IO-Link process parameter. The IO-Link sensor variants also have two independently configurable switching outputs. In addition to the standard variants, there are special sensors for uses such as ATEX areas or for oxygen applications. A wide range of process connections and electrical connections offer a high degree of flexibility in a wide range of applications.

TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 2|5 PT14500PSIG-2003-IX-H1143 | 11/08/2023 00-22 | technical changes reserved Technical data Outputs Output 1 Analog output Output function Analog output current Analog output Current output 4…20 mA Load ≤ (Supply voltage -10)/20 kΩ Resolution <± 0.1 % FS Accuracy LHR ±0.3 % FS (typical; max. ±0.5 % FS) Mechanical data Housing material Stainless-steel/Plastic, 1.4404 (AISI 316L)/polyarylamide 50 % GF UL 94 V-0 Process connection 1/4'' NPT-18 male thread Pressure connection material Stainless steel 1.4404 (AISI 316L) Pressure transducer material Stainless steel 1.4435 (AISI 316L) Wrench size pressure connection / coupling nut Max. tightening torque of housing nut 20 Nm Electrical connection Connector, M12 × 1 Protection class IP67 Environmental conditions Ambient temperature -25…+85 °C Storage temperature -50…+100 °C Shock resistance 100 g, 11 ms, half sinusoidal curve, all 6 directions, free fall from 1 m onto concrete (6x) acc. to IEC 68-2-27 Vibration resistance 20 g, 15…2000 Hz, 15…25 Hz with amplitude ± 15 mm, 1 octave/minute in all 3 directions, 50 continuous loads Tests/approvals UL registration number E302799 Reference conditions acc. to IEC 61298-1 Temperature 15…+25 °C Atmospheric pressure 860…1060 hPa abs. Humidity 45…75 % rel. Auxiliary power 24 VDC Temperature behaviour MTTF 1189 years acc. to SN 29500 (Ed. 99) 40

TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 3|5 PT14500PSIG-2003-IX-H1143 | 11/08/2023 00-22 | technical changes reserved Technical data Type PT14500PSIG-2003-IX-H1143 ID 100046100 Pressure range Pressure type Relative pressure Pressure range 0…1000 bar 0…14504 psi 0…100 MPa Admissible overpressure ≤ 1500 bar Burst pressure ≥ 2500 bar Response time < 2 ms, typ. 1 ms Long-term stability 0.25 % FS, according to IEC EN 60770-1 Power supply Operating voltage 10…30 VDC Current consumption ≤ 23 mA Short-circuit/reverse polarity protection yes / yes Protection type and class IP67 / III Insulation voltage 750 VDC Outputs Output 1 Analog output Output function Analog output current Analog output Current output 4…20 mA Load ≤ (Supply voltage -10)/20 kΩ Resolution <± 0.1 % FS Accuracy LHR ±0.3 % FS (typical; max. ±0.5 % FS) Temperature behaviour Medium temperature -30…+120 °C Temperature coefficient ± 0.2 % of full scale/10 K Environmental conditions Ambient temperature -25…+85 °C Storage temperature -50…+100 °C Vibration resistance 20 g, 15…2000 Hz, 15…25 Hz with amplitude ± 15 mm, 1 octave/minute in all 3 directions, 50 continuous loads, acc. to IEC 68-2-6 Shock resistance 100 g, 11 ms, half sinusoidal curve, all 6 directions, free fall from 1 m onto concrete (6x) acc. to IEC 68-2-27

TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 4|5 PT14500PSIG-2003-IX-H1143 | 11/08/2023 00-22 | technical changes reserved Technical data Mechanical data Housing material Stainless-steel/Plastic, 1.4404 (AISI 316L)/polyarylamide 50 % GF UL 94 V-0 Pressure connection material Stainless steel 1.4404 (AISI 316L) Pressure transducer material Stainless steel 1.4435 (AISI 316L) Process connection 1/4'' NPT-18 male thread Wrench size pressure connection / coupling nut Electrical connection Connector, M12 × 1 Max. tightening torque of housing nut 20 Nm Reference conditions acc. to IEC 61298-1 Temperature 15…+25 °C Atmospheric pressure 860…1060 hPa abs. Humidity 45…75 % rel. Auxiliary power 24 VDC Tests/approvals Approvals cULus UL registration number E302799 Important note For intrinsically safe applications, the values specified in the correspond- ing Ex certificates (ATEX, IECEX, UL etc.) apply. Ex approval acc. to conformity certificate SEV 16 ATEX 0145 Application area II 1/2 GD Ignition protection category Gas Ex ia IIC; dust Ex ia IIIC MTTF 1189 years acc. to SN 29500 (Ed. 99) 40

TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 5|5 PT14500PSIG-2003-IX-H1143 | 11/08/2023 00-22 | technical changes reserved Instructions for use Intended use This device fulfills Directive 2014/34/EU and is suited for use in areas exposed to explosion hazards according to EN 60079-0:2012 + A11:2013, EN 60079-11:2012 and EN 60079-26:2015.In order to ensure correct operation according to the intended purpose, the national regulations and directives must be observed. For use in explosion hazardous areas conform to classification The sensors may be used only in dust or gas areas Marking (see device or technical data sheet) II 1/2 GD Ex ia IIC T4 Ga/Gb and Ex ia IIIC T125°C Da/Db acc. to EN60079-0:12+A11:2013 Installation/Commissioning These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas.Please verify that the classification and the marking on the device comply with the actual application conditions. This device is only suited for connection to approved Exi circuits according to EN 60079-0 and EN 60079-11. Please observe the maximum admissible electrical values.After connection to other circuits the sensor may no longer be used in Exi installations. When interconnected to (associated) electrical equipment, it is required to perform the "Proof of intrinsic safety" (EN60079-14). Installation and mounting instructions Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and avoid build-up of dust deposits on the device.If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against strong electro-magnetic fields.The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet.In order to avoid contamination of the device, please remove possible blanking plugs of the cable glands or connectors only shortly before inserting the cable or opening the cable socket. Special conditions for safe operation The device must be protected against any kind of mechanical damage. Service/Maintenance Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important data from the approval are listed.