PST600 MITSUMI | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

Features

  1. Follows load current so that circuit current flow increases for ON, and has low current consumption for both ON and OFF. No load : I CCL=7µA typ.; ICCH=5µA typ. 2. Low operating limit voltage 0.65V typ. 3. Hysteresis voltage provided in detection voltage 50mV typ. 4. The following 10 ranks of detection voltages are available. PST600 C : 4.5V typ. H : 3.1V typ. D : 4.2V typ. I : 2.9V typ. E : 3.9V typ. J : 2.7V typ. F : 3.6V typ. K : 2.5V typ. G : 3.3V typ. L : 2.3V typ. Package MMP-3A (PST600 M) TO-92A (PST600 ) * contains detection voltage rank.

Applications

  1. Microcomputers, CPU, MPU reset circuits 2. Logic circuit reset circuits 3. Battery voltage check circuits 4. Back-up power supply switching circuits 5. Level detection circuits Equivalent Circuit

MITSUMI System Reset PST600 Absolute Maximum Ratings (Ta=25° C) Electrical Characteristics (Ta=25° C) (unless otherwise indicated resistance unit is Ω ) *2 VCC=Vs min. -0.15V Pin Assignment 123 TO-92A MMP-3A

1 VCC

2 GND

3 VOUT

Storage temperature TSTG -40~+125 ° C Operating temperature TOPR -20~+75 ° C Power supply voltage VCC max. -0.3~10 V Allowable loss Pd 200 (MMP-3A) mW300 (TO-92A) Item Symbol Measurement Measurement conditions Min. Typ. Max. Unitscircuit PST600C 4.3 4.5 4.7 PST600D 4.0 4.2 4.4 PST600E 3.7 3.9 4.1 R L=470 PST600F 3.4 3.6 3.8 Detection voltage Vs 1 V OL <= 0.4V PST600G 3.1 3.3 3.5 V VCC=H L PST600H 2.9 3.1 3.3 PST600I 2.75 2.90 3.05 PST600J 2.55 2.70 2.85 PST600K 2.35 2.50 2.65 PST600L 2.15 2.30 2.45 Hysteresis voltage Vs 1 R L=470, VCC=L H L 30 50 100 mV Detection voltage temperature coefficient Vs/ T 1 R L=470, Ta=-20° C~+75° C ±0.01 %/ ° C Low level output voltage VOL 1 VCC=Vs min. -0.05V, RL=470 0.3 0.4 V Output leak current IOH 1V CC=10V ±0.1 µA Circuit current for ON ICCL 1 VCC=Vs min. I OL=0mA 7 14 µA-0.05V I OL=8mA 50 130 Circuit current for OFF ICCH 1V CC=Vs typ./0.85V, RL=∞ 51 0 µ A H transmission delay time tPLH 2R L=4.7k, CL=100pF *1 2 04 08 0µ S L transmission delay time tPHL 2R L=4.7k, CL=100pF *1 1 02 04 0µ S Operating limit voltage VopL 1 R L=4.7k, VOL <= 0.4V 0.65 0.85 V Output current 1 for ON IOL 11 V CC=Vs min. -0.05V, RL=0 8 mA Output current 2 for ON IOL 21 Ta=-20° C~+75° C, RL=0 *2 6m A

MITSUMI System Reset PST600 Measurement Circuit [1] [2] Characteristics (PST600C is used as the representative model for characteristics examples.) -40 -20 0 20 40 60 80 4.2 4.3 4.4 4.5 4.6 4.7 VS (V) Ta(°C) VS (mV) Ta (°C) -40 -20 0 20 40 60 80 VS vs. Ta V S vs. Ta VOL (mV) Ta (°C) -40 -20 0 20 40 60 80 200 250 300 350 400 450 Ta=-25°C Ta=25°C Ta=75°C 123456 78 Vout (V) VCC (V) VCC vs. VOUT VOL vs. Ta VS 4.9 4.1 * The input model is an example of PST600C (MMP-3P). ICCH (µA) Ta(°C) -40 -20 0 20 40 60 80 ICCL (µA) IOL (mA) 02 468 1 0 1 2 100 ICCL vs. IOLI CCH vs. Ta

MITSUMI System Reset PST600 ICCL (µA) Ta (°C) -40 -20 0 20 40 60 80 ICCL (IOL=0mA) vs. Ta VOL (mV) IOL (mA) 02 468 1 0 1 2 100 200 300 400 500 IOL (mA) Ta (°C) -40 -20 0 20 40 60 80 IOL vs. Ta V OL vs. IOL Application Circuits 1. Normal hard reset Delay Time (tPLH) CL : µF Vs CPU : CPU, MPU reset threshold voltage RL : kΩ Voltage : V Note : When VCC line impedance is high, connect a capacitor between IC Pins 1 and 2. 2. Manual Reset Note : Prevent Manual SW chattering by using RL , CL and Rm. Rm setting conditions are as follows : Rm <= 1/20 RL Note : When VCC line impedance is high,connect a capacitor between IC Pins 1 and 2.

MITSUMI System Reset PST600 3. Battery Checker (LED ON for High voltage) Note : When VCC line impedance is high, connect a capacitor between IC Pins 1 and 2. 4. Battery Checker (LED ON for Low voltage) Note : When VCC line impedance is high, connect a capacitor between IC Pins 1 and 2.