Technical content
PERFORMANCE SPECIFICATIONS Nominal Voltage 12 volts (6 cells) Nominal Power (15 min.) 41 W/Cell Rated Capacity 20-hr. (525mA to 10.50 volts) 10-hr. (1.00A to 10.50 volts) 5-hr. (1.87A to 10.20 volts) 1-hr. (6.82A to 9.00 volts) 15-min. (17.2A to 9.00 volts) 10.50 AH 10.00 AH 9.35 AH 6.82 AH 4.30 AH Approximate Weight 7.00 lbs. (3.18 kg) Internal Resistance (approx.) 17.0 milliohms Max Discharge Current (5 Sec.) 31.5 amperes Max Short-Duration Discharge Current (10 Sec.) 105.0 amperes Shelf Life (% of nominal capacity at 68°F (20°C)
1 Month
3 Month
6 Month
97% 91% 83% Operating Temperature Range Charge Discharge Case and Cover Flame Retardant ABS Plastic UL94:V-0 Power Sonic Chargers PSC-122000A-C PSC-122000-PC TERMINALS (mm) DIMENSIONS inch (mm) www.power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. © 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners. All data subject to change without notice. E&O.E CORPORATE HEADQUARTERS (USA AND INTERNATIONAL EXCLUDING EMEA) Power-Sonic Corporation
7550 Panasonic Way, San Diego,
T: +1 (619) 661 2020 F: +1 (619) 661 3650 E: customer-service@power-sonic.com POWER-SONIC EUROPE LIMITED (EMEA – EUROPE, MIDDLE EAST AND AFRICA)
3 Buckingham Square,
Hurricane Way, Wickford, Essex SS11 8YQ T: +44 (0)1268 560686 F: +44 (0)1268 560902 E: salesEMEA@power-sonic.com
FEATURES
- Absorbent Glass Mat (AGM) technology for superior performance
- Designed specifically for high-rate discharge applications
- Valve regulated, maintenance free spill proof construction
- Exceptionally high energy density
- Constant power (watts/cell)
- Rugged vibration and impact resistant ABS case and cover flame retardant to UL94-V0 APPROVALS and C.A.B. certified
- U.L recognized
- ISO9001:2015 – Quality management systems UPS Data Center Telecomms Fire & Security 12 Volt 10.5 Amp. Hr. MODEL PSH-12100F2-FR BATTERYMUST BE RECYCLED Pb NONSPILLABLE
41 Watts per Cell
(UL94 V-O flame retardant) MH20845 L HT W H Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. Rev1: 11/18 PSH-12100FR 12V 10.5 AH @ 20-hr. 41 W/Cell @ 15-min. Rechargeable Sealed Lead Acid Battery PSH – High-Rate Series Torque - Not Applicable 6.35 1.5 7.95 3.4 2.5 0.8 F2: Quick disconnect tabs, 0.250" x 0.032" - Mate with AM P. INC FASTON “250” series L: 5.94 (151) W: 2.56 (65) H: 4.37 (111) HT: 4.61 (117) Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice.
www.power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. © 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners. All data subject to change without notice. E&O.E CORPORATE HEADQUARTERS (USA AND INTERNATIONAL EXCLUDING EMEA) Power-Sonic Corporation T: +1 (619) 661 2020 F: +1 (619) 661 3650 E: customer-service@power-sonic.com POWER-SONIC EUROPE LIMITED (EMEA – EUROPE, MIDDLE EAST AND AFRICA) Hurricane Way, Wickford, Essex SS11 8YQ T: +44 (0)1268 560686 F: +44 (0)1268 560902 E: salesEMEA@power-sonic.com PSH-12100FR 12V 10.5 AH @ 20-hr. 41 W/Cell @ 15-min. Rechargeable Sealed Lead Acid Battery PSH – High-Rate Series CONSTANT POWER DISCHARGE (WATTS/CELL) AT 25°C (77°F) Model Final Voltage Watts per Cell @ 25°C (68°F) 5min 10min 15min 20min 30min 45min 60min PSH-12100FR 1.75 68 47 36 27 20 15.4 13 1.70 71 52 38 29 22 16 13.2 1.67 74 57 41 32 24 16.8 13.5 CHARGING Cycle Applications: Apply constant voltage charge at Initial charging current should be set at less than 0.25C Amps. Switch to float charge to avoid overcharging. “Float” or “Stand-By” Service: Apply constant voltage charge of 2.25v/c – 2.30v/c (13.5 to 13.8 volts for 12v Monobloc at 20°C. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Temperature Compensation: Charging Voltage for both Cyclic and Standby applications should be regulated in relation to ambient temperature. As temperature rises charging voltage should be reduced to prevent overcharge and increased as temperature falls to avoid undercharge. For further charging information including temperature compensation factors, see Power Sonic Technical Manual/ Power Sonic Charger specifications.
APPLICATIONS
Power Sonic offers a wide range of chargers suitable for batteries with a variety of capacities. Please refer to our website for more information on our switch mode and transformer type chargers. Please contact our technical department for advice if you have difficulty in locating a suitable charger. FURTHER INFORMATION Please refer to our website www.power-sonic.com for a complete range of useful downloads, such as product catalogs, material safety data sheets (MSDS), ISO certification, etc.
- UPS
- Data Center
- Telecoms
- Fire and Security SHELF LIFE & STORAGE DISCHARGE CHARACTERISTICSCapacity Retention Ratio (%) Standing Period (Months) 100 0 2 4 6 8 10 12 14 16 18 20 o C (104 o o C (86 o o C (68 o o C (41 o Charging is not necessary unless 100% of capacity is required. Charging before use is necessary to help recover full capacity. SHELF LIFE & STORAGE Charge mayfail to restore full capacity. Do not let batteries reach this state. Discharge Characteristics Discharge Time Terminal Voltage (V) 13.0 min. hrs. 12.0 11.0 10.5 10.0 9.6 9.0 8.0 7.8 2010532125 18 30 6031.50 .525A.81A1.5A2.3A 5.27A 8.0A 16A24A Capacity Retention Ratio (%) Standing Period (Months) 100 0 2 4 6 8 10 12 14 16 18 20 o C (104 o o C (86 o o C (68 o o C (41 o Charging is not necessary unless 100% of capacity is required. Charging before use is necessary to help recover full capacity. SHELF LIFE & STORAGE Charge mayfail to restore full capacity. Do not let batteries reach this state. Discharge Characteristics Discharge Time Terminal Voltage (V) 13.0 min. hrs. 12.0 11.0 10.5 10.0 9.6 9.0 8.0 7.8 2010532125 18 30 6031.50 .525A.81A1.5A2.3A 5.27A 8.0A 16A24A Rev1: 11/18