PSE100 POWERBOX | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Features
- Under voltage logic alarm. Conformally coating, tropic. Reverse input voltage protection. High efficiency. Fully encapsulated, meets IP30 standard. Convectional cooled. Specifications INPUT Voltage See table Isolation Input – Output: 2kVdc (Input code A, B) Input – Output: 2.5kVac / 4kVdc (Input code C/ D) Input – Case: 2kVdc (Input code A, B) Input – Case: 2.5kVac / 4kVdc (Input – code C/ D) Output – Case: 2kVdc Reverse voltage protection Yes. OUTPUT Voltage See table. Current See table. Source regulation 0.2%. Load regulation 0.2% (0-100% load) Output ripple (100kHz) 10mV p-p (typical) Voltage adjustment 90% - 110%. Current limit protection 105%. Under voltage logic alarm 90% of nominal output. Soft start Yes. Start-up time 1s. Hold-up time 2-10ms Efficiency 80-88% ENVIRONMENTAL Operating temperature -25°C to +70°C (100% load, O/P > 10V). -25°C to +55°C (100% load, O/P < 10V). Temperature coefficient 0.02% / °C. Storage temperature -40°C to 85°C. Conformal coating Conformal coated to withstand non-condensing tropical environment RH 95% MECHANICAL Mechanical dimensions 3U x 8TE x 167mm Weight 0.85kg GENERAL Cooling Convectional cooling. Optional features -Overvoltage protection, option A.The output voltage is limited to 15% nominal output voltage. A thyristor short- circuit the output. -Undervoltage alarm with relay, option B.The logic alarm output is replaced with Relay with selectable alarm logic NO or NC. -Built in series diode, option C.A series diode on the output, when output is connected in parallel with other power supplies to achieve redundancy. Output power might be derated. -Remote sense, option S.The voltage sensing can be put at the load to compensate for voltage drop. This is standard feature on 5V output. -Inrush current limit with NTC, option H.Only for C -input code. Reduce the inrush current during the start up. The input voltage range will be affected. - 2.5kVac isolation input/case, option E1.On A and B inputs. The emission level increase to level A. - 2.5kVac isolation output/case, option E2.The emission level will increase to level A. -Train input, option T.Input voltage range according to train Standard EN50155 and IEC 60751. - Euro panel, option L 8TE for PSE 100, 10TE for 5V output with extra cooler. - Wall mounting panels, option N.Wall mounting panel with connector holder The female connector has to be chosen. - H15 screw type female, H15-S - H15 fast-on 6.3mm female, H15-T - Din rail TS35 clips, option Q. STANDARDS Safety IEC60950-1: 2001 EMI standards EN55011/EN55022 class B, IEC/EN61000-6-2, C-Tick AS/NZS CISPR11: 2002 Group1 Class A EMC standards EN61000-6-2, EN/IEC61000-4-4, EN61000-4-5
412 EURO CASSETTE
60-100 WATTS DC/DC SINGLE OUTPUT MODEL NUMBER INPUT OUTPUT COOLING POWER PSE100A5 10-30V 5V 20A Convection 60W PSE100A13.2 10-30V 13.2V 7.6A Convection 100W PSE100A15 10-30V 15V 6.7A Convection 100W PSE100A24 10-30V 24V 4.2A Convection 100W PSE100A48 10-30V 48V 2.1A Convection 100W PSE100B5 20-72V 5V 20A Convection 100W PSE100B13.2 20-72V 13.2V 7.6A Convection 60W PSE100B15 20-72V 15V 6.7A Convection 100W PSE100B24 20-72V 24V 4.2A Convection 100W PSE100B48 20-72V 48V 2.1A Convection 100W PSE100C5 50-150V 5V 20A Convection 60W PSE100C13.2 50-150V 13.2V 7.6A Convection 100W PSE100C15 50-150V 15V 6.7A Convection 100W PSE100C24 50-150V 24V 4.2A Convection 100W PSE100C48 50-150V 48V 2.1A Convection 100W PSE100D5 90-270V 5V 20A Convection 60W PSE100D13.2 90-270V 13.2V 7.6A Convection 100W PSE100D15 90-270V 15V 6.7A Convection 100W PSE100D24 90-270V 24V 4.2A Convection 100W PSE100D48 90-270V 48V 2.1A Convection 100W Selection Table Technical Illustrations