Features
Ambient Temperature (oC) 100 Vin (V) 100 100 115 130 145 160 265 250 -10 0 10 20 30 40 60 50 70 Output Derating CurveLoad (%)Load (%) Dimensions Performance Connections 7.83 2.04 3.90 6.180.700.26 0.70 2.50 0.49 0.49 0.98 5.08 0.98FAN Bottom View Direction of air /f_low 4 x M4, 5mm deep 4 x M4, 5mm deep 320W/48V with PFC Function
404 Westridge Drive
Watsonville, CA 95076 Tel: 800-525-1609 - Fax: 831-761-6544 www.applied-motion.com DISTRIBUTED BY: SPECIFICATION VALUE NOMINAL OUTPUT VOLTAGE V 48 MAXIMUM OUTPUT CURRENT A 6.7 PEAK OUTPUT CURRENT A 8.7 RATED OUTPUT POWER W 321.6 EFFICIENCY (TYP) (115/230VAC) ( * 1 )% 84 / 88 INPUT VOLTAGE RANGE 85 ~ 265VAC (47-63Hz) or 120 ~ 370VDC INPUT CURRENT (TYP) (115/230VAC) ( * 1 )A 3.6 / 1.8 INRUSH CURRENT (TYP) 40A at 115VAC, 80A at 230VAC, Ta=25 °C, Cold Start HARMONIC CURRENT Compliant to EN61000-3-2 POWER FACTOR (TYP) (115/230VAC) ( * 1 ) 0.99 / 0.95 OUTPUT VOLTAGE RANGE V 43.2~52.8 RIPPLE AND NOISE (115/230VAC) ( * 1, 2 ) mV 240 LINE REGULATION ( * 2 ) mV 96 LOAD REGULATION ( * 2 ) mV 240 TEMPERATURE COEFFICIENT Less than 0.02%/°C OVER CURRENT PROTECTION ( * 3 ) A 7.0 ~ 10 OVER VOLTAGE PROTECTION ( * 4 ) V 55.2~64.8 OVER TEMPERATURE PROTECTION ( * 4 ) Yes HOLD-UP TIME (TYP) (115/230VAC) ( * 1 ) 20ms LEAKAGE CURRENT 0.75mA Max, 0.25mA(Typ) at 115VAC / 0.5mA(Typ) at 230VAC SERIES OPERATION Yes OPERATING TEMPERATURE ( * 5 ) - 10 ~ + 65 °C (Refer to Output Derating Curve) OPERATING HUMIDITY 20 ~ 90 %RH (Non Condensing) STORAGE TEMPERATURE - 30 ~ +85°C STORAGE HUMIDITY 10 ~ 95%RH (Non Condensing) COOLING METHOD Forced Air Cooling by Fan - On Demand WITHSTAND VOLTAGE Input - Output : 3.0kVAC (10mA), Input - FG : 2.0kVAC (10mA) Output - FG : 500VAC (10mA) for 1min. ISOLATION RESISTANCE More than 100MΩ at Ta=25°C and 70%RH, Output - FG : 500VDC VIBRATION At Non Operation, 10 - 55Hz, 10min. 1 Cycle , 19.6m/s2 Constant, X, Y, Z 1 Hour each SAFETY Pending, UL60950-1, CSA60950-1, EN60950-1 EMI Compliant to FCC-Class B, EN55011/EN55022-B,CISPR22 Class B EMS IMMUNITY Compliant to EN61000-4-2,-3,-4,-5,-6,-8,-11 WEIGHT (TYP) Lb (g) 2.0 (900) DIMENSION inch (mm) 2.04 x 3.9 x 7.83 (50 x 99 x 199) (Refer to Page 1) * 1. At maximum output power, nominal input voltage, Ta = 25°C. * 2. Ripple & noise are measured at a bandwidth of 20MHz by using a 12’’ twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor. * 3. Constant current limit with automatic recovery. Avoid operating at overload or dead short for more than 60 seconds. * 4. Shuts down output voltage. Requires manual reset of AC power. * 5. Refer to output derating curve (next page) for details. 8/1/2010 925-0006 RevA