  • Anywhere in the world: +1-425-446-5500 Or, visit Fluke's website at www.fluke.com. To register your product, visit http://register.fluke.com. To view, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. Safety A Warning identifies conditions and procedures that are dangerous to the user.  Warning To prevent possible electrical shock, fire, or personal injury:
  • Read all safety information before you use the Product.
  • Carefully read all instructions.
  • Do not alter the Product and use only as specified, or the protection supplied by the Product can be compromised.
  • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
  • Do not use the Product around explosive gas, vapor, or in damp or wet environments.
  • Do not use the Product if it operates incorrectly. PN 4571866 November 2014, Rev. 1, 11/16 © 2014-2016 Fluke Corporation. All rights reserved. Product specifications are subject to change without notice.
  • Examine the case before you use the Product. Look for cracks or missing plastic. Carefully look at the insulation around the terminals.
  • Do not use the Product if it is altered or damaged.
  • Remove the batteries if the Product is not used for an extended period of time, or if stored in temperatures above 50 °C. If the batteries are not removed, battery leakage can damage the Product.
  • You must close and lock the battery door before you operate the Product.
  • Replace the batteries when the low battery indicator shows to prevent incorrect measurements. Symbols Symbols used in the instructions or on the Product are shown in Table 1.

Table 1. Symbols  Risk of danger. Important information.  Conforms to European Union directives. product in domestic household waste.

  1. Select the AC or DC function with the

selection switch on the side.

  1. Place the red probe of the test tool into the (+)

terminal and press down firmly.

  1. Place the black probe of the test tool into the

(-) terminal and press down firmly.

  1. Make sure the meter reading of the Product is

valid for the test function. Table 2. Overview of PRV240

  • Do not operate the Product with covers removed or the case open. Hazardous voltage exposure is possible.
  • Repair the Product before use if the battery leaks.
  • Have an approved technician repair the Product. To install or replace the batteries: 1. Turn the battery-door latch until the unlock symbol aligns with the arrow. 2. Lift off the battery door. 3. Insert or replace the four AA batteries. Use the correct battery orientation. 4. Install the battery door. 5. Turn the battery-door latch until the locked symbol aligns with the arrow. Specifications Output voltage

50 V ac rms minimum

for the internal function of the equipment itself. due to conducted and radiated disturbances. radio reception in such environments. occur when the equipment is connected to a test object. business environments and not to be used in homes. and workmanship for one year from the date of purchase. liability may not apply to you. Fluke Corporation Fluke Europe B.V. recognized measurement standards. This document is not a certificate of calibration or traceability.

1 K 10 K 100 K1 M 10 M2 K