650W 4" x 6" AC-DC “U” Channel Power Supply Converter https://www.murata.com/support PQU650.A04.D01 Page 1 of 12 FEATURES 2 Compact high-density design and thermal performance operation to:
- 450W3 convection at +50°C; no derating with input line voltage
- 650W with forced airflow at +50°C; no derating with input line voltage
- 800W “power boost” (at output start-up) for 30s. Voltage (+15%)2 adjustment of Main V1 Output +5VAux/Standby and 12V Fan outputs 4" x 6" industry standard footprint; “U” channel form factor with industry “standard” mounting footprints.
- 40mm maximum overall “U” Channel height
- 42.7mm max overall height with cover
- Choice of screwed or pluggable connector variants. High efficiency of 95% typical at 50% load Very low no load standby power consumption True zero load operation of the Main (V1) output; no minimum load requirements Remote sense, main output (option) Universal AC input; active PFC; EN61000-3-2 Class A MTBF 797Khrs; Telcordia SR332 Issue 3; M1 Case 3; +40ºC) RoHS3 compliant Parallel/redundant capable; droop current share as standard feature IEC62368-1 Certified Typical Applications:
- Industrial
- T elecommunications and Datacoms
- Test equipment, ATE
- Vi sual signage
- Broadcast
- PoE
1 When deployed in End User Systems
2 54V output adjustment range is +5% max to maintain max voltage to <60V. 3 PQU650-12P derated to 400W convection..
DESCRIPTION
The PQU650 Series products are rated at 650W employing a “U” channel construction to operate with natural convection or forced airflow. The PQU650 series is a 6”x 4” format capable of providing a continuous 650W1 output, with a constant current overload characteristic, and 800W “power boost” at output start4 to deliver transient loads. The compact form factor offers an impressive 450W of natural convection cooled power at +50°C. Provision of an adjustable Main output, plus Auxiliary/Standby and fan outputs, will enable this technically superior solution to be deployed across multiple market sectors, complemented by safety certification applicable to Audio/Video/Communication and ITE standards. Available options include screw terminals or plug header connectors, plus optional safety cover. ORDERING GUIDE (MODEL NUMBER) Model (Order) Number Main output (V1) Aux Output (V2) Fan Output V3 5 Voltage Vdc Current Adc; @ 50°C; 650W1 Vdc Current Adc @ 50°C Vdc Current Adc @ 50°C PQU650-12 12 54.2 5 0.5 12 0.6 PQU650-24 24 27.1 PQU650-28 28 23.2 PQU650-482 48 13.6 PQU650-542 54 12.1 PQU650-12P3 12 54.2 PQU650-24P 24 27.1 PQU650-28P 28 23.2 PQU650-48P2 48 13.6 PQU650-54P2 54 12.1 PQU-COVER3 Optional cover kit; End User assembly required. PQU650-F-COVER6 Optional cover kit with integral top mounted fan; End User assembly required. 1 Forced convection airflow required.. 2 PoE Isolation Compliant. 3 Derating for convection cooling required. 4 Any condition resulting in the Main V1 output restarting; i.e. recycling of PS_ON or recovery from OCP/OTP protection. 5 Only available for forced air cooled deployments (not available for convection cooled deployments).
6 Consult sales channel for availability
650W 4" x 6" AC-DC “U” Channel Power Supply Converter https://www.murata.com/support PQU650.A04.D01 Page 2 of 12 INPUT CHARACTERISTICS Parameter Conditions Min Nom Max Units Input Voltage AC Operating Range Single Phase 90 100-240 264 Vac Input Frequency 47 50/60 63 Hz Turn-on input voltage Input rising 75 90 Vac Turn-off input voltage Input falling 65 80 Vac Maximum input current Vin = 90VAC; Full Load1 (650W FL) 9.0 Arms Inrush Current 230Vac, Cold start, 25°C 30 Apk Power Factor At 230VAC, full load 0.95 W/VA Hold-up Time 90Vac; 650W 10 msec Efficiency @ 230VAC; 25°C 20% Full Load 92 % 50% Full Load 95 100% Full Load 94 No Load Input Power Consumption (PS_ON = OFF; Aux (V2) = 0A <0.5 W
1 Input current will increase to ≈10Arms under 800W peak power
AUXILIARY OUTPUT CHARACTERISTICS Auxiliary Output Aux Output Voltage Load Current Load Capacitance Line, Load, Cross Regulation Ripple Voltage & Noise Aux (V2) 5V 0 to 0.5A 0 to 220µF 4.75 to 5.25Vdc 100mVPP FAN OUTPUT CHARACTERISTICS (ALL MODELS) Auxiliary Output1,2 Aux Output Voltage Load Current Load Capacitance Line, Load, Cross Regulation Ripple Voltage & Noise Aux (V3) 12V 0 to 0.6A 0 to 220µF 10.8 to 13.2Vdc 120mVPP 1 Not recommended for “general use” due to its semi regulated characteristic. The output is for use with a fan intended to cool the PQU650M; therefore, if the PQU650M is convection cooled only then this output should not be used. A 1.5A non-replaceable fuse is provided in this output for overload protection. 2 Only available for forced convection cooled deployments (not available for natural convection cooled deployments). MAIN OUTPUT CHARACTERISTICS (ALL MODELS EXCEPT UNLESS NOTED) Parameter Conditions Typ. Max. Units Transient Response1 50% load step, 1A/µsec slew rate and min 10% load ± 5 % Settling Time to 1% of Nominal 500 µsec Turn On Delay After application of input power 3 sec Output Voltage Rise 200 msec Remote Sense (Option)2 Compensates for up to 120mV of total lead drop (output and return connections) with remote sense connected. Protected against short circuit and reverse connection. 1 % 1 Min. 1 second time between consecutive transients; requires 10% minimum load. 2 Remote sense fs not offered as a standard feature due to droop current share characteristic offered on the standard models; consult the sales channel for availability of remote sense option. ENVIRONMENTAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Storage Temperature Range -40 85 °C Operating Temperature Range4 See power derating curves -30 70 Operating Humidity Non-condensing 10 95 % Operating Altitude -200 50001 m MTBF Telcordia SR-332 Issue 3; M1C3 @ 25°C Telcordia SR-332 Issue 3; M1C3 @ 40°C 1810K 797K Hours Shock 30G, non-operating Complies Operational Vibration Sine Sweep; 5-150Hz, 2G Random Vibration, 5-500Hz, 1.11G Complies Safety – ITE, Audio/Video/Information and Communications Technology Equipment Standards IEC 60950-1:2005, IEC 60950-1:2005/AMD1:2009, IEC 60950-1:2005/AMD2:2013 [CSA] CAN/CSA-C22.2 No. 60950-1-07, Amendment 1:2011, Amendment 2:2014 (MOD) [CSA] ANSI/UL 60950-1-2014 [CSA] EN 62368-1: 2020/A11:2020 [TÜV SÜD] GB17625.1-2012; GB4943.1-2011; GB/T9254-2008 (Class A) [CCC] IEC 62368-1:2014 [CSA] CAN/CSA-C22.2 No. 62368-1:14; UL 62368-1 2nd Ed. [CSA] CE Marking per LVD UKCA Marking per Electrical Equipment (Safety) Regulations 2016 Fuses Dual Fuses; Line and Neutral; 12.5A Fast Acting; 250V Weight (typ.) 0.692/1.526 kg/lbs. 1 Meets 5000 M max. altitude for Medical certification requirements. 2 Starts at -30°C at 100Vac minimum input; however full specification guaranteed at -20°C.
650W 4" x 6" AC-DC “U” Channel Power Supply Converter https://www.murata.com/support PQU650.A04.D01 Page 3 of 12 PROTECTION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Over Voltage Protection V1 (main output) latching 115 140 % V1 (48V & 54V models) latching 60 Vdc V2 (aux output) latching 5.5 7.5 Over Current Protection V3, (Fuse Protected) 1.5A Adc Overload Characteristics The idealized Constant Current characteristic is shown in the curves opposite. This feature will enable the PQU650 to successfully start in to application loads exhibiting large inrush current i.e. large capacitive loads, incandescent lamps, motors and solenoids. The curves are generated for the PQU650 variants by subjecting the output to an incremental (constant resistance) load, equivalent to 1Adc increments (above full load). The resultant curve shows the current limited to an initial constant “brick wall” (shown by the blue portion of curve). If the load current is further incremented, the output will enter “hiccup” mode (recycling on/off) shown by the red dashed curve, commencing when the output voltage falls to ~75% of the nominal set point. If the overload current is maintained above maximum load for an extended period in the “hiccup” region, operation will continue indefinitely while the overload persists. In the event that the overload is maintained just below that where “hiccup” operation is initiated, then, dependent on the prevailing operating conditions, the power module may enter thermal protection. Each time the output recovers from hiccup the output power will be capable of 800W peak to provide additional power to ensure that the transient load is delivered. PROTECTION CHARACTERISTICS CONTINUED Parameter Conditions Min. Typ. Max. Units Over Current Protection V2, auto-recovery 110 150 % V3; non-resettable fuse1 1.5 Adc Over Voltage Protection2 Latching 110 140 %Vdc Over Temperature Protection Auto-recovery °C Primary Heatsink Temperature 130 Secondary Temperature 130 Remote Sense Short Circuit Protection Co mplies -- Remote Sense Reverse Connection Protection Co mplies -- 1OCP of the 12V Fan (V3) output is provided by an SMD fuse (accessible from top) rated at 1.5A; therefore if ruptured the 12V Fan output will not be available and the fuse shall require to be replaced. 2Refers to percentage of nominal voltage ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Isolation Primary to Chassis 1500 Vac Primary to Secondary 4000 Secondary to Chassis1 1500 Output to Output1 1500 Earth Leakage Current (under normal conditions) 264Vac, 60Hz, 25°C 400 µAac
1 Meets PoE isolation limits
650W 4" x 6" AC-DC “U” Channel Power Supply Converter https://www.murata.com/support PQU650.A04.D01 Page 4 of 12 CURRENT SHARING Model Number Description All PQU6501 Refer to ACAN-107 for additional details Main output current sharing is achieved using the “droop” method. Nominal output voltage is achieved at 50% load; the output voltage increases/decreases (approximately ±3% of nominal voltage) with decreasing/increasing (respectively) load current. This regulation window does not include the additional tolerance due to line, temperature, long term stability etc. Startup of parallel power supplies is not internally synchronized. No more than 800W combined power is allowed at start-up. To account for±10% full load current sharing accuracy, and the reduction in full load output voltage due to droop, available output power must be derated by 15% when units are operated in parallel. Current sharing can be achieved with or without remote sense2 connected to the common load. External ORING protection is recommended (see Application notes, ACAN-105 for additional details); Aux (V2) outputs can be tied together for redundancy but total combined output power must not exceed 2.5W; external ORing devices are recommended to preserve redundancy. It is not recommended that the 12V Fan (V3) outputs are connected in parallel since these outputs are only semi regulated and intended to power fans. 1 Except PQU650-xxR variants that are not provided with this feature. 2 Remote Sense is no provided as standard. EMISSIONS AND IMMUNITY Characteristic Standard Compliance Input Current Harmonics IEC/EN 61000-3-2 Class A Voltage Fluctuation and Flicker IEC/EN 61000-3-3 Complies Conducted Emissions CISPR 32/EN 55032 Class B FCC Part 15 Class B Radiated Emissions CISPR 32/EN 55032 Class B FCC 15.109 - 3 meter Class B ESD Immunity IEC/EN 61000-4-2 Level 4, Criterion 2 Radiated Field Immunity IEC/EN 61000-4-3 Level 3, Criterion A Electrical Fast Transient Immunity IEC/EN 61000-4-4 Level 4, Criterion A Surge Immunity IEC/EN 61000-4-5 Level 3, Criterion A (Com. Mode: 2kV 12 OHM, Diff. Mode: 1kV, 2ohm) Radiated Field Conducted Immunity IEC/EN 61000-4-6 Level 3, 10V/m, Criterion A Magnetic Field Immunity IEC/EN 61000-4-8 Level 3, Criterion A Voltage dips, interruptions IEC/EN 61000-4-11 Level 3, Criterion B STATUS AND CONTROL SIGNALS Parameter Models Conditions PS_ON Connector J3 Pin 4 All Models (Except as noted) This pin can be left unterminated (or alternatively pulled high to +5V_AUX; Connector J3 Pin 1) to (enable) turn on the main output. The +5V_AUX output is independent of the PS_ON signal, and comes up automatically when the input AC or input DC voltage is applied (within their respective specified operating ranges). If it is desired to turn off the Main Output (during normal operation) then this pin can be pulled “low” (sink current ≥2mA) to +5V_AUX_RTN. PWOK Connector J3 Pin 2 All Models The PWOK is a combined digital signal that signifies the status of the Main V1 output. It changes state due to loss of the incoming AC source and any condition that causes the Main V1 DC output shutdown (UVP, OCP, OTP protection). The output is via an open drain CMOS buffer (that has a 10K pull up resistor to an internal +5Vdc rail) that transitions high 15-25ms after the main output is within regulation; it transitions low at least 1msec before loss of regulation. PART NUMBER STRUCTURE PQU 650 - XX yyy Options P = Plugs/Receptacles for all input, output and signal Blank = Default is screwed Input and Main Output Terminals PQU = Power, Quality , “U” Channel Main Output Voltage Output Power (Watts) Example s: PQU650-24 = Base 24V Model; no options PQU650 -24P = Plug/Receptacles for all input, output and signal connections EMI CONSIDERATIONS For optimum EMI performance, the power supply should be mounted to a metal plate grounded to all 4 mounting holes of the power supply. To comply with safety standards, this plate must be properly grounded to protective earth (see mechanical dimension notes). Pre-compliance testing has shown the stand-alone power supply to comply with EN55032 class B radiated emissions with a metal enclosure with grounded base plate. See PQU-COVER for details - testing was based on adding a toroid (4 turns of both main output wires wound as common mode choke on FAIR-RITE#5961002701). Radiated emission results vary with system enclosure and cable routing paths. A minimum 10% load current is required, on the main output.
650W 4" x 6" AC-DC “U” Channel Power Supply Converter https://www.murata.com/support PQU650.A04.D01 Page 5 of 12 PERFORMANCE TYPICAL DATA EXAMPLES (BASED ON 24V VARIANT) Efficiency 24V Model Typical Ripple & Noise (24V Model) Transient Performance, 24V Model Half to Full Load Transient Performance, 24V Model Full to Half Load NB: Waveforms as shown includethe effects of 3% droop regulation. Inrush Current; 264Vac Input, Cold Start, 10.5Apk Hold Up Time; 90Vac; 650W EMI; Conducted CISPR 22; Peak vs. Average Limit; L1; 100Vac 24Vdc @ 25Adc
650W 4" x 6" AC-DC “U” Channel Power Supply Converter https://www.murata.com/support PQU650.A04.D01 Page 6 of 12 EMI; Conducted CISPR 22; Peak vs. Average Limit; L2/Neutral; 100Vac 24Vdc @ 25Adc PERFORMANCE TYPICAL DATA EXAMPLES EMI; Conducted CISPR 22; Peak vs. Average Limit; L1; 208Vac 24Vdc @ 25Adc EMI; Conducted CISPR 22; Peak vs. Average Limit; L2/Neutral; 208Vac 24Vdc @ 25Adc THERMAL CONSIDERATIONS
650W 4" x 6" AC-DC “U” Channel Power Supply Converter https://www.murata.com/support PQU650.A04.D01 Page 7 of 12 System thermal management is critical to the performance and reliability of the PQU650 series power supplies. Performance derating curvesare provided which can be used as a guideline for what can be achieved (at various operating conditions) in a system configuration with controlled airflow. The product is designed to provide 450W using natural convection cooling when mounted with an un-obstructed convection current airflow flow at up to +50°C local ambient temperature. At elevated temperatures the power supply data is recorded while it is surrounded by a large vented enclosure, to minimize forced cross flows inherent in the elevated temperature test. The product is capable of operation when mounted in diverse orientations; operational/derating cureves are provided to show the effect of such mounting. See ACAN-106 for additonal details. Capacitor Case Temperature and Mounting Orientation: The power supply can operate in any orientation; however, the power supply contains overtemperature protection that will shut off the output as the temperature of critical componenets exceed their safe and reliable thermal limits. Additonally, life expectantcy of the power supply is inversely proportional to the case temperature of electrolytic capacitors. The designer of the system in which this power supply is deployed should consider this relationship to ensure optium product life. The following charts are initial life predications, based on 80% of full load capability, and illustrate this relationship. The PQU650 Series will also benefit from the provision of forced convection cooling airflow (generated by an external host system fan). A dedicated 12V Fan (V3) output is provided that can be used to power an external (system) fan or when used in conjunction with the PQU650-F-COVER. This shall enable operation to the full capability of 650W at +50°C local ambient (forced convection cooling air) temperature. Please refer to ACAN-106 for additonal details NB: The above curves are based on generic predicted life. DERATNG CURVES Thermal Input Line
- The PQU650 will reliably provide 450W1 cooled by natural convection with no derating for AC line at a local ambient temperature of +50°C; except for PQU650-12P that is derated to 400W at +50°C.
- It is also capable of providing 300W at operation up to +70°C.
- The PQU650 will provide 650W of power with a minimum recommended airflow of 40mm this equates to circa 13CFM/ 6.14 litre/s). No derating with input line voltage for convection or forced cooling airflows for all variants in the series, except for PQU650-12P that derates to 400W when convection cooled.
650W 4" x 6" AC-DC “U” Channel Power Supply Converter https://www.murata.com/support PQU650.A04.D01 Page 8 of 12 WIRING DIAGRAM FOR OUTPUT CONNECTIONS Note: For parallel (current share) operation it is required to connect the sharing power supplies in parallel (+DC out connected together and DC out Return connected together). Since each output has an identical “droop” share characteristic then each output will intrinsically share the total load current. See ACAN-107 for more details. It is recommended that for redundant (critical) applications that external isolation devices (diodes or MOSFETS) are employed; see ACAN-105 for suggested devices.
650W 4" x 6" AC-DC “U” Channel Power Supply Converter https://www.murata.com/support PQU650.A04.D01 Page 9 of 12 MECHANICAL DIMENSIONS (Nominal) PQU650-xx MODELS Input Connector J1 Phoenix Contact Part# 1715734 Supported Cable Gauge: 26-12AWG; 0.14-2.5mm2 Pin 1 PE/GND Pin 2 AC Neutral/L2 Pin3 AC Line/L1 Output Connector J701, J701A IHI Connectors; B2A-PCB Cable stripped end or with suitable ferrule J701 +DC_OUT J701A +DC_OUT_RTN Signal Connector; J3 PCB Connector: Molex 90130-1108 (C-Grid IIITM Series Mating Half Housing: Molex 0901420008 Crimps Terminals/pins Molex 0901190109 Pin 1 +5V_AUX Pin 2 PWR_OK Pin 3 +12V_FAN_RTN Pin 4 PS_ON Pin 5 +Remote Sense Pin 6 -Remote Sense Pin 7 +12V_FAN Pin 8 +5V_AUX_RTN
650W 4" x 6" AC-DC “U” Channel Power Supply Converter https://www.murata.com/support PQU650.A04.D01 Page 10 of 12 MECHANICAL DIMENSIONS (Nominal) PQU650-xxP MODELS Input Connector J1 JST Connectors, B03P-VL (VL Series) Mating Half: JST Housing VLP-03V Crimps/Terminals: SVF-61T-P2.0; 20-14AWG & SVT-81T-P2.0 12AWG Pin 1 AC Line/L1 Pin 2 AC Neutral/L2 Pin3 PE/GND Output Connector; J701 JST Connectors; B06P-VL (VL Series) Mating Half: JST Housing VLP-06V Crimps/Terminals: SVF-61T-P2.0; 20-14AWG & SVT-81T-P2.0 12AWG Pin 1 +DC_OUT_RTN Pin 2 Pin 3 Pin 4 +DC_OUT Pin 5 Pin 6 Signal Connector; J3 PCB Connector: Molex 90130-1108 (C-Grid IIITM Series Mating Half Housing: Molex 0901420008 Crimps Terminals/pins Molex 0901190109 Pin 1 +5V_AUX Pin 2 PWR_OK Pin 3 +12V_FAN_RTN Pin 4 PS_ON Pin 5 +Remote Sense Pin 6 -Remote Sense Pin 7 +12V_FAN Pin 8 +5V_AUX_RTN SAFETY CONSIDERATIONS 1. This power supply is a component level power supply intended for use in Class I applications. 2. A protective bonding conductor from the end product protective earthing terminal must be tied to connector J1 (relevant pin dependent on connector type). 3. The primary heatsink is considered a live primary circuit and should not be touched. It is recommended that the primary heatsink be kept at least 4mm from chassis/ground and 8mm from secondary (SELV) circuitry. In all cases, the applicable safety standards must be applied to ensure proper creepage and clearance requirements are met. 4. This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: https://www.murata- ps.com/requirements/ 5. The power supply has been evaluated for 5000m altitude and tropical climatic conditions for China. 6. Double pole/neutral fusing is used; the product label is annotated accordingly. 7. If the product is used with the PQU650 cover assembly the relevant safety creepage and clearance requirements are preserved when the PQU650 if so installed. 8. For all deployment installed chassis mounting screws, the End User should ensure that the screw does not protrude by more than two (2) threads through the captive PEM mounted in the “U” channel.
650W 4" x 6" AC-DC “U” Channel Power Supply Converter https://www.murata.com/support PQU650.A04.D01 Page 11 of 12 PQU650-F-COVER ASSEMBLY VIEW (APPLICABLE TO PQU650-XX AND PQU650-XXP VARIANTS)
650W 4" x 6" AC-DC “U” Channel Power Supply Converter https://www.murata.com/support PQU650.A04.D01 Page 12 of 12 INPUT/OUTPUT CONNECTOR AND SIGNAL SPECIFICATION AND MATING CONNECTORS – PQU650-xx series Connector PIN Description Technical Data Manufacturer Input Connector J1 1 Protective Earth (PE)/Ground 300V, 10A, 3 positions. Flame Rated: UL94V-0; 5.08mm Pitch Phoenix Contact Order# 1715734 2 AC Neutral/ L2
3 AC Line/L1)
Output Connectors; J70x J701 +DC_OUT 600V, 100A, @AWG Wire Lug IHI Connectors; B2A-PCB J701A +DC_OUT_RTN Output Connector J3 1 +5V_AUX 250V, 3A, 8 positions. Flame RatedUL94V-0; 85°C (minimum) PCB Connector: Molex 90130-1108 (C-Grid IIITM Series Mating Half Housing: Molex 0901420008 Crimps Terminals/pins Molex 0901190109
2 PWR_OK
3 +12V_FAN_RTN
4 PS_ON
7 +12V_FAN 8 +5V_AUX_RTN INPUT/OUTPUT CONNECTOR AND SIGNAL SPECIFICATION AND MATING CONNECTORS – PQU650-xxP Connector PIN Description Technical Data Manufacturer Input Connector J1
1 AC Line/L1
250V, 7.5A, 3 positions. Flame Rated: UL94V-0; 5.08mm Pitch JST Connectors, B03P-VL (VL Series) Mating Half: JST Housing VLP-03V Crimps/Terminals: SVF-61T-P2.0; 20-14AWG & SVT-81T-P2.0 12AWG
2 AC Neutral/L2
3 Protective Earth (PE)/Ground
Output Connectors; J701 +DC_OUT_RTN 600V, 15A, Flame Rated at 94V-0; 90°C temperature rated JST Connectors; B06P-VL (VL Series) Mating Half: JST Housing VLP-06V Crimps/Terminals: SVF-61T-P2.0; 20-14AWG & SVT-81T-P2.0 12AWG +DC_OUT 5 Output Connector J3 1 +5V_AUX 250V, 3A, 8 positions. Flame Rated UL94V-0; 85°C (minimum) PCB Connector: Molex 90130-1108 (C-Grid III TM Series Mating Half Housing: Molex 0901420008 Crimps Terminals/pins Molex 0901190109 3 +12V_FAN_RTN 7 +12V_FAN 8 +5V_AUX_RTN APPLICATION NOTES & ASSOCIATTED DATASHEETS Document Number Description Link to Document ACAN-105 PQU650 External ORING deployment notes ACAN-105 ACAN-106 PQU650 Installation/Thermal deployment notes ACAN-106 ACAN-107 PQU650 Current Sharing deployment notes ACAN-107 PQU-COVER Cover Kit datasheet PQU650-COVER_Datasheet Murata Power Solutions, Inc.
129 Flanders Road
Westborough, MA 01581 ISO 9001 and 14001 REGISTERED This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy. Refer to: https://www.murata.com/requirements/ Murata Power Solutions, Inc. (“Murata”) makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not i nfringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, monitor failures and their consequences lessen the likelihood of failures that might cause harm, and take appropriate remedial actions. Buyer will fully indemnify Murata, its affiliated companies, and its representatives against any damages arising out of the use of any Murata products in safety-critical applications. Specifications are subject to change without notice. Customer hereby acknowledges and agrees that Murata has not made, and will not make, any representations, warranties, covenants or other statements that would in any way indicate that the Products are suitable for use in connection with medical devices, medical equipment or for any other medical purposes, whether as a stand-alone product, or combined in any way with another good, product, part, hardware or otherwise, and, to the extent permitted by applicable law, Customer hereby expressly assumes any and all liability for any and all such use of the Products. © 2024 Murata Power Solutions, Inc.