Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ PQ ASCTB206E 201202-T

ORDERING INFORMATION

Standard packing: Carton: 100 pcs.; Case: 500 pcs. * For sockets, see page 88. 1a 5A small size power relay for interface PQ RELAYS Contact arrangement Nominal coil voltage Part No.

1 Form A

(Bifurcated) 3V DC PQ1a-3V 5V DC PQ1a-5V 6V DC PQ1a-6V 9V DC PQ1a-9V 12V DC PQ1a-12V 18V DC PQ1a-18V 24V DC PQ1a-24V VDE RoHS compliant

FEATURES

  1. Compact and slim 20 mm (L) × 10 mm (W) × 16 mm (H) .787 inch (L) × .394 inch (W) × .630 inch (H) slim type 2. Twin contact structure Gold-clad twin (bifurcated) contacts provide high reliability. 3. High capacity and small size This small package can provide high 5 A capacity. 4. High sensitivity with 200 mW nominal operating power 5. 8,000 V surge breakdown voltage Despite the compact size, between contact and coil surge resistance of 8,000 V has been achieved. The relay has low susceptibility to noise. 6. Outstanding shock resistance. Functional shock resistance: 294 m/s 7. Most suitable for PLC output and internal device output relays. 8. Sealed type 9. Sockets are available. TYPICAL APPLICATIONS 1. Programmable controllers 2. Interface relays for Factory Automation and Communication equipment 3. Output relays for measuring equipment, timers, counters and temperature controllers Contact arrangement 1a: 1 Form A (Bifurcated) PQ 1a Nominal coil voltage (DC) 3, 5, 6, 9, 12, 18, 24 V Notes: 1. Certified by UL, CSA, VDE and SEMKO 2. TÜV approved type is available.

Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ PQ ASCTB206E 201202-T RATING 1. Coil data 2. Specifications Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981 *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. REFERENCE DATA Nominal coil voltage Pick-up voltage (at 20°C 68°F) Drop-out voltage (at 20°C 68°F) Nominal operating current Coil resistance Nominal operating power Max. applied voltage 3V DC 75%V or less of nominal voltage (Initial) 5%V or more of nominal voltage (Initial) 66.7mA 45 Ω 200mW 180%V of nominal voltage (at 20°C 68°F) 130%V of nominal voltage (at 70°C 158°F) 5V DC 40mA 125 Ω 6V DC 33.3mA 180 Ω 9V DC 22.2mA 405 Ω 12V DC 16.7mA 720 Ω 18V DC 11.1mA 1,620 Ω 24V DC 8.3mA 2,880 Ω Characteristics Item Specifications Contact Arrangement 1 Form A (Bifurcated) Contact resistance (Initial) Max. 50 m Ω (By voltage drop 6 V DC 1A) Contact material Au-clad AgNi type Rating Nominal switching capacity (resistive load) 5 A 250 V AC, 5 A 30 V DC Max. switching power (resistive load) 1,250 VA, 150 W Max. switching voltage 250 V AC, 110 V DC (0.3 A) Max. switching current 5 A Nominal operating power 200 mW Min. switching capacity (Reference value)* 1 100µA 100mV DC Electrical characteristics Insulation resistance (Initial) Min. 1,000M Ω (at 500V DC) Measurement at same location as “Breakdown voltage” section. Breakdown voltage (Initial) Between open contacts 1,000 Vrms for 1min. (Detection current: 10mA.) Between contact and coil 4,000 Vrms for 1min. (Detection current: 10mA.) Surge breakdown voltage (Initial)*

2 Between contacts and coil 8,000 V

Temperature rise (coil) Max. 45°C (By resistive method, nominal coil voltage applied to the coil, contact carrying current: 5 A, at 70°C) Operate time (at 20°C 68°F) (Initial) Max. 20 ms (Nominal voltage applied to the coil, excluding contact bounce time.) Release time (at 20°C 68°F) (Initial) Max. 10 ms (Nominal voltage applied to the coil, excluding contact bounce time.) (without diode) Mechanical characteristics Shock resistance Functional 294 m/s 2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.) Destructive 980 m/s 2 (Half-wave pulse of sine wave: 6 ms.) Vibration resistance Functional 10 to 55 Hz at double amplitude of 2.0 mm (Detection time: 10 µs.) Destructive 10 to 55 Hz at double amplitude of 3.5 mm Expected life Mechanical Min. 2 ×107 (at 180 times/min.) Electrical (at 20 times/min.) Min. 2 ×105 (5 A 125 V AC), Min. 105 (5 A 250 V AC), Min. 105 (5 A 30 V DC) Conditions Conditions for operation, transport and storage*3 Ambient temperature: –40°C to 70°C –40°F to 158°F; Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Max. operating speed (at rated load) 20 times/min. Unit weight Approx. 7 g .25 oz 1. Max. switching capacity 2. Operate & release time Tested sample: PQ1a-24V, 25 pcs. 3. Coil temperature rise Measured portion: Inside the coil Contact carrying current: 5 A 100 Contact current,A 0.3 10 30 Contact voltage, V AC resistive load 100 250 1,000 DC resistive load 0 80 100 120 150 Coil applied voltage, %V Operate & release time, ms Operate time Release time Max.Min. Max.Min. 0 100 110 120 130 140 150 160 50°C Coil applied voltage,%V Temperature rise,°C 70°C

Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ PQ ASCTB206E 201202-T DIMENSIONS (mm inch) SAFETY STANDARDS For Cautions for Use. UL/C-UL (Recognized) CSA (Certified) VDE (Certified) TÜV (Certified) SEMKO (Certified) E43028 5A 277V AC 1/6HP 277V AC 5A 30V DC 0.3A 110V DC LR26550 etc. 5A 277V AC 1/6HP 277V AC 5A 30V DC 0.3A 110V DC 40013088 5A 250V AC (cos φ=0.4) 5A 30V DC (0ms) B 11 05 13461 300 5A 250V AC (cos φ=0.4) 5A 30V DC (0ms) 817131 3(2)A 250V AC 5A 30V DC 4. Ambient temperature characteristics Tested sample: PQ1a-24V Contact carrying current: 5 A 300 200 100 2004 0 6 0 8 0 100 Ambient temperature, °C Coil applied voltage, %V Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115°C 239°F) Pick-up voltage with a hot-start condition of 100%V on the coil Pick-up voltage The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ External dimensions 7.62 7.627.6210.16 15.6 4.2 0.4 0.3 0.8 0.3 0.5 .300 .394 .300.300 .400 .787 .614 .165 .016 .012 .031 .012 .020 Schematic (Bottom view) PC board pattern (Bottom view) Tolerance: ±0.1 ±.004 COM Coil N.O. 7.62 7.6210.16 4-1.3 dia. .300 .300 .400 4-.051 dia. CAD Data Dimension: Less than 1mm .039inch: Min. 1mm .039inch less than 5mm .197 inch: Min. 5mm .197 inch: General tolerance ±0.2 ±.008 ±0.3 ±.012 ±0.4 ±.016