Technical content
125W Single Output with PFC Function PPS125 series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 Universal AC input Protections: Short circuit / Overload / Over voltage Built-in active PFC function PWM control and regulated High power density 6.117W/cubic inch Built-in remote sense function 125W with 18CFM FAN 5”x3” compact size Model Number Output Volts Output Amps OVP DC Volt Adjust Min Load(Convection) Min Load(18CFM FAN) TRIPLE OUTPUT PPS125-5 5 Volts(DC) 20 Amps 5.5~6.75Volts(DC) 4.75~5.25Volts(DC) 0~20Amps 0~25Amps
125W Single Output with PFC Function PPS125 series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 INPUT SPECIFICATIONS Input Voltage Range 90-264VAC / 127-370 Volts(DC) Frequency Range 47-63 Hz Inrush Current, typ: (cold start) 24Amps / 230VAC Input Current 3.3Volts(DC): 1.2Amps / 115VAC; 0.6Amps / 230VAC 5Volts(DC): 1.7Amps /115VAC; 0.75 Amps / 230VAC Leakage current < 2mA / 240 VAC Power Factor PF >0.93 / 230VAC >0.98 / 115VAC OUTPUT SPECIFICATIONS Voltage and Current See Selection Chart Line Regulation ±0.5% Load Regulation ±1.0% Voltage Tolerance (Note 2) ±0.2%: 3.3~15Volts(DC) ±1.0%: 24~48Volts(DC) Ripple/Noise (Note 1) 100mVpk-pk: 3.3~15Volts (DC) 150mVpk-pk: 24~27Volts(DC) 250mVpk-pk: 48Volts(DC) Hold Up Time @ FL 24mS @ 230VAC 24mS @ 115VAC Setup, Rise Time @ FL 1000mS, 30mS/230VAC 2000mS. 30mS/115VAC Over Voltage Protection 5.75~6.75Volts: 5Volts(DC) (PPS125B/C/D) 3.6~4.45Volts: 3.3Volts(DC) (PPS125A) Hiccup mode, auto recover Over Current Protection 130~160% rated output power Fold back current limiting, auto-recover DC Voltage Adjust 4.75~5.25Volts: 5Volts(DC) (PPS125B/C/D) 3.13~3.46Volts: 3.3Volts(DC) (PPS125A) GENERAL SPECIFICATIONS Safety UL60950-1 TUV EN60950-1 approved Insulation Resistance ≥ 100MΩ / 500Volts(DC) / 25°C / 70%RH EMI Compliance to EN55011B (CISPR11B) Harmonic Current Compliance to EN61000-3-2,-3 Efficiency 70% (PPS-125-3.3) 79% (PPS-125-5) 84% (PPS-125-48) Isolation 3000VAC Input - Output 1500VAC Input - Ground 500VAC Output - Ground EMS Compliance to ENV50204, EN55024, light industry level, criteria A ENVIRONMENTAL SPECIFICATIONS Oper. Temperature -20°C to +70°C (See Derate Curve) Storage Temperature -40°C to +85°C, 10~95% RH Relative Humidity 20 to +90% RH Temperature Coefficient ±0.05% / °C (0-50°C) MTBF 111.7KHrs min, MIL-HDBK-217F (25°C) Vibration 10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes PHYSICAL SPECIFICATIONS Size Millimeters 127 x 76.2 x 34.6 Inches 5” x 3” x 1.36” Weight 13.05 oz (370g) NOTE 1. Ripple and Noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor. 2. Tolerance: includes set up tolerance, line regulation and load regula- tion. 3. Heat Sink HS1,HS2 & HS3 can not be shorted. All specifications are typical at nominal input, full load, and 25°C unless other- wise noted
125W Single Output with PFC Function PPS125 series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458
125W Single Output with PFC Function PPS125 series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458