CPTC Thermistor: Twin SMD Type PPL Serie s Overload Protection for Telecom Application ■■ ■■ Features 1. RoHS compliant 2. Two resistance-matched PTCs in a plastic housing 3. Wide resistance range in telecom area from 10 to 50Ω 4. Agency recognition: UL/cUL/TUV 5. Compliant with ITU-T standards 6. Operating temperature range :0 ~ +60° C (V=Vmax) /square6 Recommended Applications 1. Cable Modem, ADSL Modem with VOIP 2. Customer Premise Equipment (CPE) 3. Central Office (CO) 4. Access Equipment (AE) 5. Main Distribution Frame (MDF) 6. Public Switched Telephone Network (PSTN) 7. Exchanger /square6 Part Number Code P P L 0 7 5 0 0 M A 0 C 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Product Code PPL PTC Thermistor for Overload Protection Dimensions 07 ψ7mm Resistance (R 25 ) 7R0 7Ω 100 10 Ω 500 50 Ω Tolerance of R 25 K ±10% L ±15% M ±20% H ±25% N ±30% Y Special Curie temperature P8 80 ℃ A0 100 ℃ A2 120 ℃ A4 140 ℃ Voltage A4 140V AC B5 250V AC C0 300V AC Internal Control Code

CPTC Thermistor: Twin SMD Type PPL Serie s Overload Protection for Telecom Application ■■ ■■ Structure and Dimensions ■■ ■■ Characteristics Note1: □=Tolerance of R 25 Note2: UL/cUL File No. E138827 TUV File No. R 50171789 Nominal Zero-power Resistance Resistance Matching In Housing Non- operating Current at 25 ℃ Non- operating Current at 40 ℃ Trip Current at 25 ℃ Responding Time (s) Max Voltage Max. Current Safety Approvals Part No. R 25 (Ω) ∣R 1-R2∣ (Ω) IN (mA) @25 ℃ IN (mA) @40 ℃ It (mA) @25 ℃ 3A → 0.5A 1A → 0.5A 0.5A → 0.15A (V AC ) Imax (A) UL/ cUL TUV PPL07100 □A0B5-Y 10 130 120 390 0.8 8.0 35 250 2.5 √ √ PPL07180 □A0B5-Y 18 110 100 330 0.4 2.5 10 250 3 √ √ PPL07250 □A0B5-Y 25 90 80 225 0.35 2.0 10 250 3 √ √ PPL07390 □A0B5-Y 39 70 65 180 0.3 1.0 4.0 250 3 √ √ PPL07500 □A0C0-Y 50 ±0.5 60 55 165 0.15 0.8 3.5 300 3 √ √

CPTC Thermistor: Twin SMD Type PPL Serie s Overload Protection for Telecom Application R-T Characteristic Curves (Typical) ■■ ■■ Circuit for Typical Application PPL07500 /box3/box3 /box3/box3A0B5 PPL07390 /box3/box3 /box3/box3A0B5 PPL07250 /box3/box3 /box3/box3A0B5 PPL07180 /box3/box3 /box3/box3A0B5 PPL07100 /box3/box3 /box3/box3A0B5 PTC PTC PTC PTC Primary Protection Secondary Protection Subscriber Lines Voltage Clamp Subscriber Loop Interface Circuit (SLIC) or Transformer 25 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 Temperature (℃℃ ℃℃) 10 8 10 7 10 6 10 5 10 4 10 3 10 2 10 1 10 0

CPTC Thermistor: Twin SMD Type PPL Serie s Overload Protection for Telecom Application ■■ ■■ Soldering Recommendation /circle6 IR-Reflow Soldering Profile /circle6 Recommended Reworking Conditions With Soldering Iron Item Conditions Temperature of Soldering Iron-tip 360 ℃ (max.) Soldering Time 3 sec (max.) Diameter of Soldering Iron-tip Φ3mm (max.) 3°C /sec (max.) 60~180 sec 20~40 sec 150±20 ℃ Time 255~260 °C 150~200 °C Tamb 3° C/sec (max.) 217 °C 60~150 sec t 8 minutes max Preheating Cooling 6°C /sec (max.)

CPTC Thermistor: Twin SMD Type PPL Serie s Overload Protection for Telecom Application ■ Reliability Item Standard Test conditions / Methods Specifications Solderability IEC60068-2-58 245 ±5℃ , 3 ±0.3 sec. At least 95% of terminal electrode is covered by new solder Resistance to Soldering Heat IEC60068-2-58 255 ±5℃ ,10 ±1 sec. R/R∣∣ 25 20% ∣∣ No visible damage Vibration IEC60068-2-6 Frequency range: 10~55Hz Amplitude: 0.75mm or 98m/S2 Direction: 3 mutually perpendicular directions, 2hrs each. R/R∣∣ 25 20% ∣∣ No visible damage Shock IEC60068-2-27 Wave: half-sine ⊿V:1.0m/s Acceleration: 50m/s2 Pulse time:30ms R/R∣∣ 25 20% ∣∣ No visible damage Rapid Change of Temperature IEC60068-2-14 The rapid change conditions shown below shall be repeated 5 cycles. Step Temperature( ℃) Period(minutes) 1 -40 ± 3 30 ± 3

2 Room temperature 5 ± 3

3 85 ± 2 30 ± 3

4 Room temperature 5 ± 3

R/R∣∣ 25 20% ∣∣ No visible damage Climatic Sequence IEC60738-1 +40 ,℃ 20%R.H X 24hrs →100 X 16hrs→25 X 2hrs→℃ ℃ +40 ,℃ 95%R.HX 24hrs→ 0 X 2hrs→+40 ,℃ ℃ 95%R.HX 24hrs →

25 X (1~2)hrs℃

R/R∣∣ 25 20%∣∣ No visible damage High Temperature Storage IEC60068-2-2 60 ℃, for 1000 hrs R/R∣∣ 25 20%∣∣ No visible damage High Temperature Continuous Load IEC60738-1 60 ℃, Vmax, It<I<Imax for 1000 hrs R/R∣∣ 25 20%∣∣ No visible damage Damp Heat, Steady State IEC60068-2-3 40 ±2℃, 90~95%RH, for 1000 ±2 hrs R/R∣∣ 25 20% ∣∣ No visible damage Over Current Specification Standard 220Vrms, 3A, 60s on and 600s off , ×20 cycles ∣△R/R25 ∣≦20% No visible damage Power Contact ITU-T K.20 9.4 230Vrms,10 Ω, 15Min ∣△R/R25 ∣≦20% No visible damage Lightning Surge ITU-T K30 4.2.5 DC:1.0KV ﹐10/1000µs,25A,×30 cycles DC:1.5KV ﹐10/310µs,37.5A,x10cycles ∣△R/R25 ∣≦20% No visible damage Power Induction Specification Standard 650Vrms, 600 Ω, 1s on and 60s off ×10 cycles ∣△R/R25 ∣≦20% No visible damage

CPTC Thermistor: Twin SMD Type PPL Serie s Overload Protection for Telecom Application ■ Packaging /circle6 Taping Specification ■■ ■■ Quantity Reel packing: 400 pcs / reel Item Nominal dimensions Tolerance D 330 ±5 W 17.5 ±0.5 t 5 ±0.5 D1 75 ±1.5 ■ Storage condition of products /circle6 Storage Conditions : 1. Storage Temperature : -10 ~+℃ 40 ℃ 2. Relative Humidity : 75%RH∣ 3. Keep away from corrosive atmosphere and sunlight. /circle6 Period of Storage: 1 year. Index Nomin al dimensions Tolerance W 16.00 ±0.30 P 16.00 ±0.10 E 1.75 ±0.10 F 7.50 ±0.10 P2 2.00 ±0.10 P0 4.00 ±0.10 A0 8.4 ±0.10 B0 8.9 ±0.10 K0 9.3 ±0.10 t 0.5 ±0.05 (Unit: mm) (Unit: mm)