4262 PICO | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 5
Technical content
A digital oscilloscope for the analog world Supplied with an SDK including example programs • Free Technical Support
- Software compatible with Windows 7, Windows 8 and Windows 10 Low noise Two channels
16 MS buffer
10 MS/s sampling
5 MHz bandwidth
Low-distortion signal generator Arbitrary waveform generator USB powered 16 bit ...from a name you can trust PicoScope 4262 Oscilloscope PicoScope 4262 HIGH-RESOLUTION USB OSCILLOSCOPE
Digital triggering reduces trigger errors and allows our oscilloscopes to trigger on the smallest signals, even at the full bandwidth. Trigger levels and hysteresis can be set with great precision and resolution. Digital triggering also reduces re-arm delay and this combined with the segmented memory allows the triggering and capture of events that happen in rapid sequence. At the fastest timebase you can use rapid triggering to capture a new waveform every microsecond. The mask limit testing function can then scan through these waveforms to highlight any failed waveforms for viewing in the waveform buffer. Arbitrary waveform and function generator The unit has a built-in signal generator (sine, square, triangle, DC level). As well as basic controls to set level, offset and frequency, more advanced controls allow you to sweep over a range of frequencies. Combined with the spectrum peak hold option, this makes a powerful tool for testing amplifier and filter responses. Also included is a fully programmable arbitrary waveform generator with a 4 k-sample buffer. High-end features as standard To protect your investment, both the API and the firmware inside the unit can be updated. We have a long history of providing new features for free via software downloads. Other companies make vague promises about future enhancements but we deliver on our promises year after year. Users of our products reward us by becoming lifelong customers, frequently recommending us to their colleagues. High signal integrity Most oscilloscopes are built down to a price; ours are built up to a specification. Careful front-end design and shielding reduces noise, crosstalk and harmonic distortion. Years of oscilloscope experience enable us to achieve improved pulse response and bandwidth flatness. We are proud of the dynamic performance of our products and publish these specifications in detail. The result is simple: when you probe a circuit with a PicoScope, you can trust in the data you capture. Low distortion, low noise The PicoScope 4262 from Pico Technology is a 2-channel, 16 -bit high-resolution oscilloscope with a built-in low-distortion signal generator. With its 5 MHz bandwidth, it can easily analyze audio, ultrasonic and vibration signals, characterize noise in switched mode power supplies, measure distortion, and perform a wide range of precision measurement tasks. Full-featured oscilloscope The PicoScope 4262 is a full-featured oscilloscope, with a function generator and arbitrary waveform generator that includes a sweep function to enable frequency response analysis. It also offers mask limit testing, math and reference channels, advanced digital triggering, serial decoding, automatic measurements and color persistence display. Designed for the analog world When used in spectrum analyzer mode, the scope provides a menu of eleven automatic frequency-domain measurements such as IMD, THD, SFDR and SNR. Its performance is so good that it rivals many dedicated audio analyzers and dynamic signal analyzers costing several times the price. Most digital oscilloscopes have been designed for viewing fast digital signals. The trend has been to use new technology solely to increase sampling rate and bandwidth. With the PicoScope 4262 we have focused on what’s important for measuring analogue signals: increasing the resolution, improving dynamic range, and reducing noise and distortion. Advanced triggers As well as the standard range of triggers found on all oscilloscopes, the PicoScope 4262 offers a comprehensive set of advanced digital triggers including pulse width, windowed and dropout triggers to help you capture the data you need. www.picotech.com Introduction to the PicoScope 4262
PicoScope 4262 Specifications www.picotech.com VERTICAL Number of channels 2 Input connectors BNC Bandwidth (-3 dB) 5 MHz (4 MHz on ±20 mV range, 3 MHz on ±10 mV range) Bandwidth limiter 200 kHz, switchable Rise time (calculated) 70 ns (88 ns on ±20 mV range, 117 ns on ±10 mV range) Resolution 16 bits (20 bits in enhanced resolution mode) Input impedance 1 MΩ ±2% ∥ 15 pF ±2 pF Input coupling AC/DC Input sensitivity 2 mV/div to 4 V/div (10 vertical divisions) Input ranges ±10 mV, ±20 mV, ±50 mV, ±100 mV, ±200 mV, ±500 mV, ±1 V, ±2 V, ±5 V, ±10 V, ±20 V DC accuracy (% of full scale) ±0.25% (±0.5% on ±50 mV range , ±1% on ±20 mV range, ±2% on ±10 mV range) Overvoltage protection ±50 V (DC + AC Peak) HORIZONTAL Maximum sampling rate (real-time) 10 MS/s (1 or 2 channels in use) Maximum sampling rate (USB streaming) 10 MS/s using PicoScope 6 software. 10 MS/s (1 channel in use), 6.7 MS/s (2 channels in use) using supplied SDK. Buffer memory 16 MS Waveform buffer (no. of segments) 10 000 (with supplied software), 32 768 (in SDK) Timebase ranges 1 ns/div to 5000 s/div Timebase accuracy ±50 ppm Sample jitter < 10 ps RMS ADC sampling Simultaneous sampling on all enabled channels DYNAMIC PERFORMANCE (typical) Crosstalk > 50 000:1 Total harmonic distortion −95 dB typical at 10 kHz, −1 dBfs input SFDR 96 dB typical at 10 kHz, −1 dBfs input Pulse response <1% overshoot all ranges Bandwidth flatness +0.25 dB to –3 dB, DC to full bandwidth Noise 8.5 μV RMS (on most sensitive range) TRIGGERS (CHANNELS A & B) Trigger modes None, auto, repeat, single, rapid (segmented memory) Basic trigger types Rising, falling Advanced digital trigger types Edge, window, pulse width, window pulse width, dropout, window dropout, interval, runt pulse, logic Trigger sensitivity (Ch A, Ch B) Digital triggering provides 1 LSB accuracy up to full bandwidth of scope Max. pre-trigger capture Up to 100% of capture size Max. post-trigger delay Up to 4 billion samples Trigger re-arm time < 10 µs on fastest timebase EXT TRIGGER Trigger types Edge, pulse width, dropout, interval, logic, delayed Input characteristics Rear panel BNC, 1 MΩ ±2% ∥ 15 pF ± 2 pF Threshold range ±5 V and ±500 mV, DC coupled Sensitivity 25 mV p-p at 1 MHz, typical DC accuracy ± 1% Bandwidth 5 MHz Overvoltage protection ± 50 V SPECTRUM ANALYZER Frequency range DC to 5 MHz Windowing functions Rectangular, Gaussian, triangular, Blackman, Blackman-Harris, Hamming, Hann, flat-top Display modes Magnitude, peak hold, average Number of FFT points 128 to 1 million MATH CHANNELS Functions −x, x+y, x−y, x*y, x/y, sqrt(x), x^y, exp(x), ln(x), log(x), abs(x), norm(x), sign(x), sin(x), cos(x), tan(x), arcsin(x), arccos(x), arctan(x), sinh(x), cosh(x), tanh(x) Operands Input channels A and B, time, reference waveforms, pi
Protocols I2C, CAN Bus, SPI, RS232/UART, I2S, LIN MASK LIMIT TESTING Statistics Pass/fail, failure count, total count DISPLAY MODES Interpolation Linear or sin (x)/x Persistence modes Digital color, analog intensity, custom, fast SIGNAL GENERATOR Standard output signals Sine, square, triangle, DC voltage, ramp, sinc, Gaussian, half-sine, white noise, PRBS Bandwidth 20 kHz Output frequency accuracy ±50 ppm Output frequency resolution < 0.01 Hz Output voltage range ±1 V (into high impedance load) Offset voltage adjustment 100 μV steps (within overall ±1 V range) DC accuracy ±0.5% of full scale Amplitude flatness < 0.1 dB to 20 kHz, typical SFDR 102 dB typical @ 10 kHz, −1 dBfs input Connector type Front panel BNC Output characteristics 600 Ω Overvoltage protection ±10 V Sweep modes Up, down, dual with selectable frequency and sweep time AWG Update rate 192 kS/s Buffer size 4096 samples Resolution 16 bits Bandwidth 20 kHz Rise time (10% to 90%) 11 μs, typical AUTOMATIC MEASUREMENTS Scope mode AC RMS, true RMS, frequency, cycle time, duty cycle, DC average, falling rate, rising rate, low pulse width, high pulse width, fall time, rise time, minimum, maximum, peak to peak Spectrum mode Frequency at peak, amplitude at peak, average amplitude at peak, total power, THD %, THD dB, THD+N, SFDR, SINAD, SNR, IMD Statistics Minimum, maximum, average, standard deviation GENERAL PC connectivity USB 2.0 (USB 1.1 compatible) Power requirements Powered from USB port Dimensions 210 x 135 x 40 mm (including connectors) Weight < 0.5 kg Temperature range Operating: 0 °C to 45 °C (20 °C to 30 °C for stated accuracy). Storage: −20 °C to +60 °C. Humidity range Operating: 5% to 80% RH, non-condensing. Storage: 5% to 95% RH, non-condensing. Safety approvals Designed to EN 61010-1:2010 Compliance RoHS and WEEE compliant. CE: Tested to EN61326-1:2006. FCC: Tested to part 15 subpart B. Software included PicoScope 6, SDK and example programs PicoScope software PC requirements Microsoft Windows 7, Windows 8 or Windows 10, 32-bit or 64-bit Languages Chinese (simplified & traditional), Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Romanian, Russian, Spanish, Swedish, Turkish Specifications Continued... Have you seen our PicoScope 4000 Series data sheet? It shows the full range of features available with the PicoScope software, which turns your PicoScope 4262 into a powerful oscilloscope and spectrum analyzer. All of these capabilities are included in the price of your oscilloscope. www.picotech.com
& Function Generator The front panel of the PicoScope 4262 has two BNC input channels and a BNC output for the function generator and AWG. The rear panel of the PicoScope 4262 has two connections: a USB port for connection to the PC, and a BNC for an external trigger to be connected. USBTrigger Input Your PP799 PicoScope 4262 product pack contains the following items:
- 2 x MI007 probes
- PicoScope 4262
- USB cable
- Quick Start Guide
- Software and Reference CD
Ordering information
ORDER CODE PART DESCRIPTION USD* EUR* GBP* PP799 PicoScope 4262 16-bit oscilloscope with 2 probes 1235 1045 859 *Prices are correct at the time of publication. Sales taxes not included. Please contact Pico Technology for the latest prices before ordering. UK headquarters: Pico Technology James House Colmworth Business Park St. Neots Cambridgeshire PE19 8YP United Kingdom +44 (0) 1480 396 395 +44 (0) 1480 396 296 sales@picotech.com Errors and omissions excepted. Pico Technology and PicoScope are internationally registered trade marks of Pico Technology Ltd. US headquarters: Pico Technology
320 N Glenwood Blvd
+1 800 591 2796 +1 620 272 0981 sales@picotech.com PicoScope 4262 Connections