PMT2_V03 DELTA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 12

Technical content

PMT2 Panel Mount Power Supply PMT2 200 W series / PMT-□V200W2B□□ TECHNICAL DATASHEET All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated. www.DeltaPSU.com (July 2021, Rev. 01) PMT2 Highlights & Features

  • Household appliance approvals for pollution degree 3 to IEC/EN 60335-1, IEC/EN 61558-1 and IEC/EN 61558-2-16
  • AC input voltage range selectable by switch (90-132 Vac, 180-264 Vac)
  • No load power consumption < 0.5 W
  • Low profile design: 30 mm height
  • Over voltage category III
  • Wide operating temp -30°C ~70°C (Support -40°C cold start)
  • Conforms to harmonic current IEC/EN/BS EN 61000-3-2, Class A
  • High MTBF > 700,000 hrs per Telcordia SR-332 Safety Standards CB Certified for worldwide use Model Number: PMT-☐V200W2B☐☐ Unit Weight: 0.42 kg (0.926 lb) Dimensions (L x W x H): 159 x 97 x 30 mm (6.26 x 3.82 x 1.18 inch) General Description PMT 2nd generation (PMT2) power supplies is designed with low profile, offers selectable AC switch input with nominal output voltage. The highly efficient convection cooling construction can operate from -30°C to 70°C. The single output is specifically designed with compact and competitively priced for household electrical appliances safety approvals to pollution degree 3 as well as including IEC/EN 60335-1, IEC/EN 61558-2-16, IEC 60950-1 & IEC/EN/UL 62368-1 . Model Information PMT2 Panel Mount Power Supply Model Number Input Voltage Range Rated Output Voltage Rated Output Current PMT-12V200W2B☐☐ 90-132 Vac, 180-264 Vac (Selectable by Switch) 12 Vdc 17.0 A PMT-24V200W2B☐☐ 24 Vdc 8.8 A PMT-36V200W2B☐☐ 36 Vdc 5.9 A PMT-48V200W2B☐☐ 48 Vdc 4.4 A Model Numbering CC code PM T – □V 200W 2 B □ □ Panel Mount Product Type T – Enclosed Output Voltage 12 – 12 V 24 – 24 V 36 – 36 V 48 – 48 V Output Power Single Phase with Low Profile Family Code: B With No PFC Connector Type With UL, TUV, CE R – Terminal Block With UL M – Terminal Block Blank – Without connector cover & coating B – With single side coating*1 *1 : 12V/24V models only

PMT2 Panel Mount Power Supply PMT2 200 W series / PMT-□V200W2B□□ TECHNICAL DATASHEET All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated. www.DeltaPSU.com (July 2021, Rev. 01) Specifications Model Number PMT-12V200W2B☐☐ PMT-24V200W2B☐☐ PMT-36V200W2B☐☐ PMT-48V200W2B☐☐ Input Ratings / Characteristics Nominal Input Voltage 100-120 Vac, 200-240 Vac (Selectable by Switch) Input Voltage Range 90-132 Vac, 180-264 Vac (Selectable by Switch) Nominal Input Frequency 50-60 Hz Input Frequency Range 47-63 Hz Input Current 4 A typ. @ 115 Vac, 2.2 A typ. @ 230 Vac Efficiency at 100% Load @ No Load Power Consumption < 0.5 W @ 230 Vac Max Inrush Current (Cold Start) 60 A typ. @ 230 Vac Leakage Current < 0.5 mA @ 240 Vac / 50 Hz Output Ratings / Characteristics*2 Nominal Output Voltage 12 Vdc 24 Vdc 36 Vdc 48 Vdc Factory Set Point Tolerance

12 Vdc ± 1% 24 Vdc ± 1% 36 Vdc ± 1% 48 Vdc ± 1%

Output Current 0-17.0 A 0-8.8 A 0-5.9 A 0-4.4 A Line Regulation ± 0.5% typ. @ 100-132 Vac, 180-264 Vac (Selectable by Switch) Load Regulation ± 1% typ. @ 100-132 Vac, 180-264 Vac (Selectable by Switch) ± 0.5% typ. @ 100-132 Vac, 180-264 Vac (Selectable by Switch) PARD*3 (20MHz) < 150 mVpp @ 0°C to 70°C, 450 mVpp typ. @ -30°C to 0°C < 200 mVpp @ 0°C to 70°C, 600 mVpp typ. @ -30°C to 0°C Rise Time 30 ms typ. @ 115 Vac & 230 Vac Start-up Time 500 ms typ. @ 115 Vac & 230 Vac Hold-up Time 30 ms typ. @ 115 Vac & 230 Vac Dynamic Response (Overshoot & Undershoot O/P Voltage) ± 10% @ 115 & 230 Vac input, 10-100% load (Slew Rate: 2.5 A / μS, 50% duty cycle @ 5 Hz & 10 KHz) Start-up with Capacitive Loads 8,000 µF Max 8,000 µF Max 3,000 µF Max 2,000 µF Max *2 : For power de-rating from > 50°C to 70°C, see power de-rating on page 3. *3 : PARD is measured with an AC coupling mode, and in parallel to end terminal with 0.1µF ceramic capacitor & 47µF electrolytic c apacitor. PSU need to burn in > 5 minutes when AMB ≤ 0℃

PMT2 Panel Mount Power Supply PMT2 200 W series / PMT-□V200W2B□□ TECHNICAL DATASHEET All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated. www.DeltaPSU.com (July 2021, Rev. 01) Mechanical Case Chassis Aluminum Case Cover SGCC Dimensions (L x W x H) 159 x 97 x 30 mm (6.26 x 3.82 x 1.18 inch) Unit Weight 0.42 kg (0.926 lb) Indicator Green LED (DC OK) Cooling System Convection Terminal M 3.5 x 7 Pins (Rated 300 V / 20 A) Wire AWG 18-12 Current rating can refer to page 6 “Wire AWG Table” Noise (1 Meter from power supply) Sound Pressure Level (SPL) < 25 dBA Environment Surrounding Air Temperature Operating -30°C to +70°C ( -40°C Cold Start ) Storage -40°C to +85°C Power De-rating > 50°C de-rate power by 2% / °C < 100 Vac de-rate power by 2% / V (80% load @ 90 Vac) Operating Humidity 20 to 90% RH (Non-Condensing) Operating Altitude 0 to 5,000 Meters (0 to 16,400 ft) Shock Test Non-Operating IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions Operating IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions. Vibration Non-Operating IEC 60068-2-6, Random: 5 Hz to 500 Hz (2.09 G); 20 min per axis for all X, Y, Z direction Operating IEC 60068-2-6, Sine Wave: 20 Hz to 500 Hz (5 G); 10 min per cycle, 60min for each axis (X, Y,Z) Over Voltage Category II (Compliance to EN 62477-1 OVC III with 2000 meters altitude) Pollution Degree 3 Protections Overvoltage 13.2 V - 17.4 V SELV Output, Latch Mode 26.4 V - 33.6 V SELV Output, Latch Mode 39.6 V - 48.6 V SELV Output, Latch Mode 52.8 V - 64.8 V SELV Output, Latch Mode Overload / Overcurrent 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) Over Temperature Latch Mode Short Circuit Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) Protection Against Shock Class I with PE*4 connection *4 : PE: Protection Earth Reliability Data MTBF > 700,000 hrs as per Telcordia SR-332 I/P: 230 Vac, O/P: 100% Load, Ta: 25°C) Expected Cap Life Time 10 years (230 Vac, 50% load @ 40°C)

PMT2 Panel Mount Power Supply PMT2 200 W series / PMT-□V200W2B□□ TECHNICAL DATASHEET All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated. www.DeltaPSU.com (July 2021, Rev. 01) Safety Standards / Directives Safety Entry Low Voltage SELV Electrical Safety TUV Bauart cULus CB scheme CCC KC EAC BSMI cULus CB scheme EAC PMT-☐V200W2BR☐: EN 62368-1,EN 60335-1, EN 61558-1/-2-16 UL 62368-1, and CAN/CSA C22.2 No. 62368-1 IEC 62368-1, IEC 60950-1, IEC 60335-1, IEC 61558-1/-2-16 GB 4943 (design compliance) K 60950-1 (12 & 24 V model) TP TC 004/2011 CNS 14336-1 PMT-☐V200W2BM☐: UL 62368-1, and CAN/CSA C22.2 No. 62368-1 IEC 62368-1, IEC 60950-1 TP TC 004/2011 CE PMT-☐V200W2BR☐: In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU UKCA PMT-☐V200W2BR☐: In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016 Galvanic Isolation Input to Output 4.0 KVac Input to Ground 2.0 KVac Output to Ground 1.25 KVac

PMT2 Panel Mount Power Supply PMT2 200 W series / PMT-□V200W2B□□ TECHNICAL DATASHEET All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated. www.DeltaPSU.com (July 2021, Rev. 01) EMC Emissions (CE & RE) PMT-☐V200W2BR☐: CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, KN32, AS/NZS CISPR 32 Compliance to EN/BS EN 55014-1, FCC Title 47, EN/BS EN 61000-6-3 : Class B PMT-☐V200W2BM☐: CISPR 32, EN/ BS EN 55032, FCC Title 47: Class B (With Delta EMI filter P/N: 12DCCG5B) Immunity PMT-☐V200W2BR☐: EN/BS EN 55035, KN35, EN/BS EN 61000-6-2 & Compliance to EN/BS EN 55014-2,EN/BS EN 61000-6-1 Electrostatic Discharge IEC 61000-4-2 Level 4 Criteria A1) Air Discharge: 15 kV Contact Discharge: 8 kV Radiated Field IEC 61000-4-3 Level 3 Criteria A1)

80 MHz – 1 GHz, 10 V/M with 1 kHz tone / 80% modulation

Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A1) 2 kV Surge IEC 61000-4-5 Level 4 Criteria A1) Common Mode4): 4 kV Differential Mode5): 2 kV Conducted IEC 61000-4-6 Level 3 Criteria A1) 150 kHz - 80 MHz, 10 Vrms Power Frequency Magnetic Fields IEC 61000-4-8 Level 4 Criteria A1)

30 A/Meter

Voltage Dips and Interruptions IEC 61000-4-11 0% residual; 1 cycle, Criteria B 40% residual; 10 cycle, Criteria C3) 70% residual; 25 cycle, Criteria C3) Harmonic Current Emission IEC/EN/ BS EN 61000-3-2 Class A (PMT-☐V200W2BR☐ only) 1) Criteria A: Normal performance within the specification limits 2) Criteria B: Output out of regulation, or shuts down during test. Automatically restored to normal operation after test. 3) Criteria C: Output out of regulation, shuts down during test (Need to recycle AC power cord to normal operation after test) 4) Asymmetrical: Common mode (Line to earth) 5) Symmetrical: Differential mode (Line to line) Block Diagram

PMT2 Panel Mount Power Supply PMT2 200 W series / PMT-□V200W2B□□ TECHNICAL DATASHEET All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated. www.DeltaPSU.com (July 2021, Rev. 01) Device Descriptions 1) Input & Output terminal block connector 2) DC voltage adjustment potentiometer 3) DC OK control LED (Green) 4) AC selectable switch

PMT2 Panel Mount Power Supply PMT2 200 W series / PMT-□V200W2B□□ TECHNICAL DATASHEET All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated. www.DeltaPSU.com (July 2021, Rev. 01) Dimensions L x W x H: 159 x 97 x 30 mm (6.26 x 3.82 x 1.18 inch) Wire AWG Table Current rating for PVC Wire AWG 6 AWG 52.5 A 20 AWG 6.5 A 8 AWG 37.5 A 22 AWG 5.0 A 10 AWG 29.0 A 24 AWG 3.5 A 12 AWG 22.5 A 26 AWG 2.5 A 14 AWG 16.5 A 28 AWG 2.0 A 16 AWG 12.0 A 30 AWG 1.5 A 18 AWG 9.0 A

PMT2 Panel Mount Power Supply PMT2 200 W series / PMT-□V200W2B□□ TECHNICAL DATASHEET All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated. www.DeltaPSU.com (July 2021, Rev. 01) Engineering Data Output Load De-rating VS Surrounding Air Temperature Output Load De-rating VS Input Voltage 100 110 -30 -20 -10 0 10 20 30 40 50 60 70 Percentage of Max Load(%) Surrounding Air Temerature(°C) 100 110 180 100 200 132 264 Load (%) Input Voltage (Vac) Fig. 1 De-rating for Horizontal Mounting Orientation > 50°C de-rate power by 2.0% / °C Note 1. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1 & Fig.2. 2. The PSU will be bouncing and s tart up time will not exceed 5 s when ambient temperature at ‐30 °C 3. If the output capacity is not reduced when the surrounding air temperature >50°C, the device will run into Over Temperature Protection. When activated, power supply will latch off, until the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition, and require removal/re-application of input AC voltage in order to restart. 4. In order for the device to function in the manner intended, it is also necessary to keep a safety distance as recommended in the safety instructions while the device is in operation. 5. Depending on the surrounding air temperature and ou tput load delivered by the power supply, the device can be very hot!  No output power de-rating for the input voltage from 100 Vac to 264 Vac Fig. 2 De-rating for AC Input Voltage < 100 Vac de-rate power by 2% / V 180 ~ 264Vac 90 ~ 132Vac

PMT2 Panel Mount Power Supply PMT2 200 W series / PMT-□V200W2B□□ TECHNICAL DATASHEET All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated. www.DeltaPSU.com (July 2021, Rev. 01) Assembly & Installation Ⓐ Mounting holes for power supply assembly onto the mounting surface. The power supply shall be mounted on minimum 2 mounting holes using M3 screw minimum 5 mm (0.20 inch) length. Ⓑ This surface belongs to customer’s end system or panel where the power supply is mounted. Ⓒ Connector Base Mounting (Horizontal) * If the device has to be mounted in any other orientation, please contact info@deltapsu.com for more details.

  • Use flexible cable (stranded or solid) of AWG No. 18- 12. User should calculate and select the suitable wire specification The insulation stripping length should not exceed 0.275” or 7 mm. (Refer to Fig. 3). Installation of Mounting Accessories Fig. 3 Assembly Reference

PMT2 Panel Mount Power Supply PMT2 200 W series / PMT-□V200W2B□□ TECHNICAL DATASHEET All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated. www.DeltaPSU.com (July 2021, Rev. 01) Fig. 4 Mounting Screw Safety Instructions

  • If user’s mounting orientation is not according to the recommended mounting orientations, please consult Delta for further information.
  • To ensure sufficient convection cooling, always maintain a safety distance of ≥ 50 mm (1.97 inch) from all ventilated surfaces while the device is in operation.
  • The device is not recommended to be placed on low thermal conductive surface. For example, plastics.
  • The enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning!
  • Do not touch the terminals while power is being supplied. Risk of electric shock.
  • Prevent any foreign metal, particles or conductors from entering the device through the openings during installation. It may cause: Electric shock; Safety Hazard; Fire; Product failure
  • The power supply must be mounted by metal screws onto a grounded metal surface. It is highly recommended that the Earth terminal on the connector be connected to the grounded surface. Functions Start-up Time The time required for the output voltage to reach 90% of its final steady state set value, after the input voltage is applied. Rise Time The time required for the output voltage to change from 10% to 90% of its final steady state set value. Hold-up Time Time between the collapse of the AC input voltage, and the output falling to 95% of its steady state set value. ■ Graph illustrating the Start-up Time, Rise Time, and Hold-up Time  Only use M3 screw ≤ 3 mm (0.20 inch) through the base mounting holes. This is to keep a safe distance between the screw and internal components.

PMT2 Panel Mount Power Supply PMT2 200 W series / PMT-□V200W2B□□ TECHNICAL DATASHEET All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated. www.DeltaPSU.com (July 2021, Rev. 01) Inrush Current Inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. Dynamic Response The power supply output voltage will remains within ± 10% of its steady state value, when subjected to a dynamic load from 10% to 100% Overload & Overcurrent Protections (Auto-Recovery) The power supply’s Overload (OLP) and Overcurrent (OCP) Protections will be activated when output current exceeds 110% of I O (Max load). In such occurrence, the V O will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into “Hiccup mode” (Auto-Recovery). The power supply will recover once the fault condition of the OLP and OCP is removed and I O is back within the specifications. It is not recommended to prolong the duration of Io when it is <110% but >100%, since it may cause damage to the PSU. Short Circuit Protection (Auto-Recovery) The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. Overvoltage Protection (Latch Mode) The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on under “Protections”. Power supply will latch, and require removal/re- application of input AC voltage in order to restart. The power supply should be latch, and require removal /re- apply of input AC voltage in order to restart. Over Temperature Protection (Latch Mode) As described in Engineering data section, the power supply also has Over Temperature Protection (OTP). In the event of a higher operating temperature at 100% load, the power supply will run into OTP when the operating temperature is beyond what is recommended in the de-rating graph. When activated, t he output voltage will go into latch mode until the temperature drops to its normal operating temperature as rec ommended in the de -rating graph.

PMT2 Panel Mount Power Supply PMT2 200 W series / PMT-□V200W2B□□ TECHNICAL DATASHEET All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated. www.DeltaPSU.com (July 2021, Rev. 01) Others Attention Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shal l prevail (please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for eval uation of using the product before placing an order with Delta. Delta reserves the right to make changes to the information described in the datasheets without notice. Manufacturer and Authorized Representatives Information: Manufacturer: Thailand: Delta Electronics (Thailand) PCL. 909 Pattana 1 Rd., Muang, Samutprakarn, 10280 Thailand Taiwan: Delta Electronics, Inc.

3 Tungyuan Road, Chungli Industrial Zone, Taoyuan County

32063, Taiwan Authorized representatives: The Netherlands: Delta Greentech (Netherlands) B.V. Zandsteen 15, 2132 MZ Hoofddorp, The Netherlands United Kingdom: Delta Electronics Europe Limited

1 Redwood Court, Peel Park Campus,

East Kilbride, Glasgow, G74 5PF, United Kingdom