PS-PMRMC GREYSTONE | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM ROOM PARTICULATE MATTER SENSOR PMRMC SERIES PRODUCT DESCRIPTION The PMRMC Particulate Matter Sensor uses an optical sensor based on laser scattering principles and features innovative contamination resistance technology to perform highly accurate and reliable PM measurements. The replaceable sensor measures particles of PM1.0, PM2.5, PM4.0, and PM10, with a continuous operation lifetime of more than 8 years. The sensor will provide long-term reliability and high resolution particle size binning for the detection of environmental dust and other particles. TYPICAL INSTALLATION For complete installation and wiring details, please refer to the product installation instructions. The PMRMC series can be mounted directly to a single gang electrical box or directly to a wall. The backplate includes many mounting hole configurations to allow for mounting on a variety of electrical boxes. The basic PMRMC has a screw block terminal provided for connection to the Building Automation System. SENSOR Laser scatter method (field replaceable) PARTICULATE SIZE PM1.0, PM2.5, PM4.0, or PM10 (selectable) MASS CONCENTRATION RANGE 0 - 1000 ug/m3 RESOLUTION 1 ug/m3 ACCURACY ±10 ug/m3 (0 - 100 ug/m3), ±10% (100 - 1000 ug/m3) RESPONSE TIME 1 second SENSOR LIFETIME >8 years ANALOG MODEL Consumption: 75 mA max @ 24 Vdc, 100 mA max @ 24 Vac Output Signals: 4-20 mA (sourcing) or 0-5 Vdc / 0-10 Vdc (selectable) Output Drive Capability: Current - 550Ω max Voltage - 5,000Ω min Output Scale: 0 to 1000 ug/m3 (menu selectable) BACnet® MODEL Consumption: 50 mA max @ 24 Vdc, 80 mA max @ 24 Vac Interface: MS/TP , 2 wire RS-485 Baud Rate: 9600, 19200, 38400, 57600, 76800 or 115200 (menu selectable) Address Range: 0 - 127 (menu selectable) MODBUS MODEL Consumption: 50 mA max @ 24 Vdc, 80 mA max @ 24 Vac Interface: MS/TP , 2 wire RS-485, RTU Baud Rate: 9600, 19200, 38400, 57600, 76800 or 115200 (menu selectable) Address Range: 1-255 (menu selectable) TRI-COLOR LED (OPTIONAL) Good: Green (0 - 50 ug/m3) Moderate: Yellow (51 - 150 ug/m3) Poor: Red (151 - 1000 ug/m3) PM ALARM RELAY (OPTIONAL) Contact Ratings: Form C (NO + NC), 2A @ 140 Vac, 2A @ 30 Vac Setpoint + Hysteresis: Programmable via menu Time Display: Programmable via menu LCD SIZE 35mm W x 15mm H (1.4” x 0.6”) LCD BACKLIGHT Enable or disable via menu DISPLAY VALUE Mass Concentration: 0 - 1000 ug/m3 Air Quality Index: 0 - 500 AQI Good/Moderate/Poor (menu selectable) POWER SUPPLY 24 Vac/dc ±20% (non-isolated half-wave rectified) PROTECTION CIRCUITRY Reverse voltage protected, overvoltage protected OPERATING CONDITIONS 0 to 50°C (32 to 122°F), 20 to 80 %RH non-condensing STORAGE CONDITIONS -30 to 60°C (-22 to 140°F) ENCLOSURE White ABS, UL94-V0, IP30 (NEMA 1) ENCLOSURE DIMENSIONS 84mm W x 117mm H x 29mm D (3.3” x 4.6” x 1.15”) WIRING Screw terminal block (14 to 22 AWG) WEIGHT 150 gm (5.3 oz) COUNTRY OF ORIGIN Canada SPECIFICATIONS 84 mm 3.3" 29 mm 1.15" 119 mm 4.7" 58 mm 2.3" 82.6 mm 3.25" Cover PCB Backplate

PRINTED IN CANADA Copyright © Greystone Energy Systems Inc. All Rights Reserved www.greystoneenergy.com PS-PMRMCXXX-05 Greystone Energy Systems, Inc.

150 English Drive, Moncton,

New Brunswick, Canada E1E 4G7 Ph: +1 (506) 853-3057 Fax: +1 (506) 853-6014 North America: 1-800-561-5611 E-mail: mail@greystoneenergy.com WIRING INFORMATION TERMINAL FUNCTION PWR + 24 Vdc/24 Vac (HOT) COM Common OUT Analog Output NO Digital Output R. COM Digital Output NC Digital Output If BACnet® or Modbus Output Selected B(+) Network Output A(-) Network Output SHLD Network Output LED DISPLAY: AIR QUALITY INDEX VALUES 0 to 50: Good 51 to 100: Moderate 101 to 150: Unhealthy for Sensitive Groups 151 & up: Unhealthy Tri-color system developed in relation to the EPA Air Quality Index as found at: https://airnow.gov/index.cfm?action=aqibasics.aqi PRODUCT PMRMC Room Particulate Matter Sensor LCD DISPLAY C V Concealed Viewable LED X L None Viewable Tri-Color LED RELAY X R None Alarm Relay OUTPUT X B M Analog Output Only BACnet® and Analog Outputs Modbus and Analog Outputs ORDERING PMRMC PART NUMBER NOTE: Greystone Energy Systems, Inc. reserves the right to make design modifications without prior notice. ACCESSORIES PMFRSM Replaceable sensor module and wire harness MCERTS CERTIFICATION The PMRMC series incorporates the SPS30 PM sensor for accurate and reliable PM sensing. The SPS30 particulate matter sensor has achieved MCERTS certification, which proves the performance of the PM sensor. In addition, the certification confirms that the SPS30 can be easily integrated into applications that comply with the European Air Quality Standard DIN EN 15267. The MCERTS certification scheme was established by the UK’s Environment Agency and is built around international and European standards to ensure high- quality environmental data monitoring. The SPS30 underwent laboratory and field tests and has been proven to fulfill the latest MCERTS and associated DIN EN 15267 European air quality standards. Compliance with the above-mentioned standards requires low intra-model variability (≤ 5 µg/m3), making the SPS30 the first choice for integration into applications requiring high precision. The certification is issued by the Sira Certification Service, one of the leading notified bodies in Europe. They are also accredited according to ISO/IEC 17065 UKAS and are part of the Canadian Standards Association (CSA Group). Learn more about the MCERTS certification on the website of CSA Group or have a look at the certificate as linked below.. Website: https://www.csagroupuk.org/services/mcerts/mcerts-product-certification/mcerts-certified-products/mcerts-certified-products-indicative-ambient-particulate-monitors/ Certificate: https://www.sensirion.com/fileadmin/user_upload/customers/sensirion/Dokumente/9.6_Particulate_Matter/Datasheets/Sensirion_PM_Sensors_Datasheet_SPS30_MCERTS-Certificate_2020.pdf 0 to 50 51 to 150 151 & up