Features
- RoHS lead free solder and lead solder exempted products are available
- 208/240 VAC input
- 48 VDC output
- Input overvoltage disconnection
- Thermal protection
- Active load sharing
- Hot swappable
- Up to 92% efficient
- International standards compliance
- Natural convection cooling
- Low weight
Description
The PMP 13.48 is a convection-cooled rectifier delivering superior reliability in harsh environmental conditions where fan-cooled products may not deliver the reliability requ ired to ensure maximum network asset performance. With leading-edge patented resonant conversion topology, the PMP13 industry-leading efficiencies of 93.5% deliver significant operating expenditure savings in the network on utility and HVAC costs. Power-One also recognizes that typical network loads operate between 20-60%; hence the PMP13 unique “flat” efficiency ensures minimal energy loss down to 15% of installed capacity The PMP 13 is optimized for telecom applications, and is designed to work in PPS10 systems incorporating the PCS controller and various distribution options with up to 6 units per 19”/6U shelf and up to 8 units per 23”/6U shelf.
NOV 07, 2006 Page 2 of 2 www.power-one.com PMP 13.48 Rectifier Data Sheet NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as components in life support systems, equipment used in hazardous environments, or nuclear control sy stems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specif ications are subject to change without notice. Input Model PMP 13.48 Input Voltage 205-250 VAC ±10% single phase, (44-66 Hz) (185-160 V at reduced output power) Current (max.) <6.8 A Soft Start <12 A peak max. 100 ms Harmonics EN 61000-3-2 Power Factor >0.99 at max. load Surge Immunity EN 61000-4-5 Fuse T 10A Connection IEC-320/C14 EMC EN 61000-6-2, EN 61000-6-3, FCC Part 15 Class B Output Model 13.48 Output Voltage 44 - 56 VDC Power (max.) 1300 W at 50-56 VDC Current (max.) 28 A Efficiency (at 40-90% load)* >92% Tolerance Vout ± 1.0% Transient Response ± 5% at load variation 10-90% or 90-10%, recovery time 10 ms Load Sharing <5% of nominal current Ripple <100 mV p-p (BW. 30 MHz) Psophometric <2 mV, according to CCITT norms Connection DIN 41612F EMC EN 61000-6-2, EN 61000-6-4 Mechanical Dimensions (WxHxD) 62 x 261 x 231 mm (2.4 x 10.3 x 9.1 in) Weight 3.1 kg (6.8 lb) Cooling Natural Convection Insulation Reinforced insulation, tested at: 4.25 kVDC primary-secondary 2.12 kVDC primary-ground 0.75 kVDC secondary-ground Enclosure IP20 Mounting Up to 8 modules per shelf Other Technical Data Safety EN 60950 UL 1950 and IEC60950 , Class 1 CSA C22-2 No. 950 Protection Short-circuit proof, automatic current limiting, selective shutdown of modules at excessive output voltage. Thermal protection reduces the output power at environmental temperatures above maximum level. Shut down at >75 °C with an automatic restart.* Input overvoltage disconnection at >275 VAC with automatic reset at >260 VAC. Indications Green LED Red LED Red LED Power ON High output voltage/ shutdown Low voltage/ module failure Audible Noise <35 dBA Operating Temperature -25 to +55 °C up to 2000 m -25 to +45 °C above 2000 m Storage Temperature -40 to +85 °C Radiated EMC EN 61000-6-2, EN 61000-6-3, FCC Part 15, Class B Environment Storage: Transport: Operation: ETS 300 019-2-1 ETS 300 019-2-2 ETS 300 019-2-3 *Average performance for a single module.