PMP110 POWERBOX | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Features
- In compliance with EN61000-3-2, EN61000-3-3 and EN61000-1-1-2. Thermal protection. Overvoltage protection. Overcurrent protection. 100% burn-in at full rated load. Specifications INPUT Input Voltage 90-132/180-264Vac Frequency 47Hz–67Hz Input Current 3.2A (rms) for 115Vac. 1.8A (rms) for 230Vac. Leakage current 90µA max. @ 115Vac. 60Hz. 150µA max. @ 230Vac. 50Hz. Insulation Input – Output: 4000VAC Input – Ground: 1500VAC Output – Ground: 500VAC Inrush Current 15A @ 115V, 30A @ 230V OUTPUT Output Voltage See table Output Current See table Ripple & Noise 1% peak to peak Line Regulation ±0.2% maximum at full load. Load Regulation See table Transient Response Max. deviation 4% recovering to 1% within 500µs after 25% load charge Overvoltage Protection Provided on V1 only. Set at 110%–132% of nominal. Overcurrent Protection All outputs protected for short circuit conditions Temperature Coefficient All outputs ±0.04% per °C. Holdup Time Typically 12ms at 110VAC. PFD Signal (Optional) Power fail detection signal. TTL logic low upon loss of input power. OPERATING MTBF 550,000 hrs @ 25°C Efficiency 65-70% minimum. ENVIRONMENTAL Operating Temperature 0°C to 70°C Derating Derate to 50% at 70°C Storage Temperature -40°C to 85°C Relative Humidity 5%–95% non-condensing STANDARDS AND APPROVALS Safety standards UL2601-1, CSA C22.2, TUV EN60601-1 C-Tick AS/NZS CISPR11 Group 1, Class A EMC standards EN60601-1-2: 2001,EN61000-3-2, -3, EMI standards EN55011 Class B, FCC Class B, VCCI Class B MEPS compliance TBC MECHANICAL Dimensions 254x127x68.58mm Weight 1.4kgs approx.
MEDICAL & MILITARY 366 MAX. MODEL OUTPUT #1 OUTPUT #2 OUTPUT #3 OUTPUT #4 OUTPUT NUMBER VNOM IMIN IMAX TOL VNOM IMIN IMAX IPEAK TOL VNOM IMIN IMAX TOL VNOM IMIN IMAX TOL POWER PMP110-23 +5V 0.8A 10A 5% +12V 0A 5A 9.0A 5% (N/A) (N/A) 110W PMP110-31 +5V 0.8A 10A 5% +12V 0A 5A 9.0A 5% -12V 0A 2A 5% (N/A) 110W PMP110-32 +5V 0.8A 10A 5% +15V 0A 4A 7.5A 5% -15V 0A 2A 5% (N/A) 110W PMP110-40 +5V 0.8A 10A 5% +12V 0A 5A 9.0A 5% -12V 0A 2A 5% -5V 0A 2A 5% 110W PMP110-41 +5V 0.8A 10A 5% +15V 0A 4A 7.5A 5% -15V 0A 2A 5% +24V 0A 2A 5% 110W PMP110-42 +5V 0.8A 10A 5% +12V 0A 5A 9.0A 5% -12V 0A 2A 5% +12V 0A 2A 5% 110W PMP110-45 +5V 0.8A 10A 5% +12V 0A 5A 9.0A 5% -12V 0A 2A 5% +24V 0A 2A 5% 110W PMP110-45-1 +5V 2A 10A 5% +12V 0A 5A 9.0A 5% -12V 0A 2A 5% +24V 1.5A 3A 10% 110W PMP110-45-2 +5V 0.8A 10A 5% +24V 0A 3A 5.0A 5% -12V 0A 2A 5% +12V 0A 2A 5% 110W PMP110-46 +5V 0.8A 10A 5% +15V 0A 4A 7.5A 5% -15V 0A 2A 5% -5V 0A 2A 5% 110W NOTES: (1) Peak output current with 10% maximum duty cycle for less than 60 seconds. Total peak power must not exceed 130 watts. (2) The output 1 of model PMP110-45-1 needs a minimum current of 2A to support the other outputs at their maximum rated loads. Selection Table PMP110 Series
110 WATTS MULTIPLE OUTPUT AC/DC MEDICAL
Return N.C. Output 1 N.C. Output 2 Common Return Output 1 N.C. or PFD PMP110-31 PMP130-32 Common Return Output 3 Output 1 N.C. Output 2 Common Return Output 1 N.C. or PFD PMP130-40 PMP130-41 PMP130-45 PMP130-45-1 PMP130-45-2 PMP130-46 Common Return Output 3 Output 1 Output 4 Output 2 Common Return Output 1 N.C. or PFD Pin Chart Technical Illustration