PMKC03 ASTRODYNE | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

Isolated and Regulated 3 WATT Modular DC/DC Converters PMKC03 series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 Low 5V or Wide 2 : 1 Input Range PI Input Filter Regulated Outputs 1600V Isolation 3.3 to 15VDC Outputs Standard Pinouts Model Number Output Voltage Output mAmps Input Range Efficiency SINGLE OUTPUT PMKC03-05S33 3.3 VDC 600 4.5-6.0 VDC 61% PMKC03-12S33 3.3 VDC 600 9-18 VDC 65% PMKC03-24S33 3.3 VDC 600 18-36 VDC 66% PMKC03-48S33 3.3 VDC 600 36-75 VDC 68% PMKC03-05S05 5 VDC 500 4.5-6.0 VDC 70% PMKC03-05S12 12 VDC 250 4.5-6.0 VDC 75% PMKC03-05S15 15 VDC 200 4.5-6.0 VDC 75% DUAL OUTPUT PMKC03-05D05 +/-5 VDC +/-300 4.5-6.0 VDC 70% PMKC03-05D12 +/-12 VDC +/-125 4.5-6.0 VDC 75% PMKC03-05D15 +/-15 VDC +/-100 4.5-6.0 VDC 75% Unit measures 0.8”W x 1.25”L x 0.4”H

Isolated and Regulated 3 WATT Modular DC/DC Converters PMKC03 series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 INPUT SPECIFICATIONS Input Voltage Ranges: 5 VDC Nominal 4.5-6.0 VDC

12 VDC Nominal 9-18 VDC

24 VDC Nominal 18-36 VDC

48 VDC Nominal 36-75 VDC

Voltage and Current See Selection Chart Load Regulation (singles/duals) +/- 0.2% / +/- 2% (25%-FL) Line Regulation (PMKC03) +/- 0.5% Temperature Coefficient +/-0.02%/°C Ripple/Noise(Single/Dual) 1% Pk-Pk, max. Voltage Accuracy +/- 2%, typ Voltage Balance, Dual Outputs +/- 2%, typ Short Circuit Protection Continuous GENERAL SPECIFICATIONS Input-Out Isolation 1600VDC Isolation Resistance 10000 M Ohms In/Out Capacitance 300 pF Efficiency See Selection Chart Switching Frequency 100 Khz ENVIRONMENTAL SPECIFICATIONS Oper. Temperature -25 to +71°C * Cooling Free Air Convection Storage Temperature -55 to +125°C * MTBF 1090 kHrs MIL-HDBK-217F TA=25C (FL) PHYSICAL SPECIFICATIONS Case Material Non-Conductive Black Plastic Construction Fully Encapsulated Weight 0.5 oz, (14g) Dimensions 1.25”x0.80”x0.40” * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. All specifications are typical at nominal input, full load, and 25DegC unless otherwise noted

Isolated and Regulated 3 WATT Modular DC/DC Converters PMKC03 series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 MECHANICAL DIMENSIONS Pin # Single Outputs Dual Outputs 1 + Input + Input

2 NC - Output

3 NC Common

22 NC Common

23 NC - Output

)8.13( 52.1 0.60(15.2) 0.80(20.3) 0.40 (10.2) 0.15 (3.8) )9.22( 09.0 )5.2( 01.0 0.08(2.0) Pin size is 0.02(0.5) Dia or 0.01 x 0.02 (0.25 x 0.50) Rectangular pin 50 60 70 80 90 100-40-25 0-10 100 AMBIENT TEMPERATURE (ºC) )%( REWOP TUPTUO Nature convection