PMH Panel Mount Power Supply 24V 100W 1 / PMH-24V100WCA□ All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2015, Rev. 02) PMH Highlights & Features – Household appliance approvals IEC/EN 60335-1, IEC/EN 61558-1 and IEC/EN 61558-2-16 – Universal AC input voltage – Full power from -20°C to +50°C operation @ 5000m or 16400 ft. altitude – Full corrosion resistant aluminium casing – No load power consumption < 0.5W – High MTBF > 700,000 hrs as per Telcordia SR-332 – Versatile connector options available: IP20, Front Face and Harness connectors Safety Standards CB Certified for worldwide use Model Number: PMH-24V100WCA☐ Unit Weight: 0.43 kg (0.95 lb) Dimensions (H x W x D): 158 x 97 x 38 mm (6.22 x 3.82 x 1.50 inch) General Description The PMH -24V100WCA☐offers universal input from 85Vac to 264Vac with nominal output voltage of 24V. The highly efficient convection cooling construction can operate from -30°C to 70°C. The PMH series is specifically designed for household electrical appliances with safety approvals including IEC/EN 60335 -1 and IEC/EN 61558- 2-16, as well as IEC/EN/UL 60950-1. In addition, the product meets the EMC approvals to EN 55014- 1 / EN 55014- 2 for household appliances and EN 61000 -6-1 / EN 61000- 6-3 for residential environment without extra EMI filter required and comes with several connector options consisting of Terminal Block, IP20, Front Face and Harness connectors. Other available options include isolation or non- isolation between Primary Earth and output DC Return (-V pins on output connector). Model Information PMH Panel Mount Power Supply Model Number Input Voltage Range Rated Output Voltage Rated Output Current PMH-24V100WCA☐ 85-264Vac (120-375Vdc) 24Vdc 4.16A Model Numbering PM H – 24V 100W C A □ Panel Mount Product Type H – Household Series Output Voltage Output Power Package Type C – Enclosed No PFC Connector Type and Primary Earth to Output DC Return Connection. See options in table below *Options A,S J,U L,V H,T

PMH Panel Mount Power Supply 24V 100W 1 / PMH-24V100WCA□ All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2015, Rev. 02) Specifications Input Ratings / Characteristics Nominal Input Voltage 100-240Vac Input Voltage Range 85-264Vac Nominal Input Frequency 50-60Hz Input Frequency Range 47-63Hz Nominal DC Input Voltage 125-250Vdc DC Input Voltage Range 120-375Vdc Input Current < 1.90A @ 115Vac, < 1.00A @ 230Vac Efficiency at 100% Load > 87.0% @ 115Vac, > 89.0% @ 230Vac Max Power Dissipation < 0.5W @ 115Vac & 230Vac (0% load) Max Inrush Current (Cold Start) < 50A @ 115Vac, < 100A @ 230Vac Leakage Current < 1.5mA @ 264Vac Output Ratings / Characteristics* Nominal Output Voltage 24Vdc Factory Set Point Tolerance 24Vdc ± 2% Output Voltage Adjustment Range 22-28Vdc Output Current 4.16A (100W max.) Output Power 100W Line Regulation < 0.5% (@ 85-264Vac input, 100% load) Load Regulation < 0.5% (@ 85-264Vac input, 0-100% load) PARD** (20MHz) < 100mVpp Rise Time < 20ms @ nominal input (@ -20°C to 70°C) < 30ms @ nominal input (@ < -20°C to -30°C) Start-up Time < 1300ms @ 100Vac (100% load) < 750ms @ 240Vac (100% load) Hold-up Time > 15ms @ 115Vac, > 100ms @ 230Vac (100% load) Dynamic Response (Overshoot & Undershoot O/P Voltage) ± 5% @ 85-264Vac input, 0-100% load (Slew Rate: 0.1A/μS, 50% duty cycle @ 5Hz to 100Hz) Start-up with Capacitive Loads 8,000µF Max *For power de-rating from < -20°C to -30°C, and 50°C to 70°C, see power de-rating on page 3. **PARD is measured with an AC coupling mode, 5cm wires, and in parallel with 0.1µF ceramic capacitor & 47µF electrolytic capacitor .

PMH Panel Mount Power Supply 24V 100W 1 / PMH-24V100WCA□ All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2015, Rev. 02) Mechanical Case Chassis / Cover Aluminium Dimensions (L x W x D) 158 x 97 x 38 mm (6.22 x 3.82 x 1.50 inch) Unit Weight 0.43 kg (0.95 lb) Indicator Green LED (DC OK) Cooling System Convection Terminal PMH-24V100WCAA (S) M3.5 x 7 Pins (Rated 300V/15A) PMH-24V100WCAJ (U) M3.5 x 7 Pins (Rated 300V/20A) PMH-24V100WCAL (V) M3.5 x 7 Pins (Rated 300V/20A) PMH-24V100WCAH (T) Input: B3P(6-2.3.5)-VH(LF)(SN) Output: B4P7-VH(LF)(SN) Wire PMH-24V100WCAA (S) AWG 20-14 PMH-24V100WCAJ (U) AWG 20-12 PMH-24V100WCAL (V) Noise (1 Meter from power supply) Sound Pressure Level (SPL) < 25dBA Environment Surrounding Air Temperature Operating -30°C to +70°C Storage -30°C to +85°C Power De-rating -20°C to -30°C de-rate power by 2.0% / °C > 50°C de-rate power by 2.5% / °C Operating Humidity 5 to 95% RH (Non-Condensing) Operating Altitude 0 to 5,000 Meters (16,400 ft.) Shock Test (Non-Operating) IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms,1 times per direction, 2 times in total Vibration (Non-Operating) IEC 60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak); displacement of 0.35mm; 20 min per axis for all X, Y, Z direction Bump (Operating) IEC 60068-2-29, 10G (100m/S²) for a duration of 11ms,1000 times per direction, 6000 times in total Pollution Degree 2 Protections Overvoltage 28.8-35.2V range, Hiccup Mode, Non-Latching (Auto-Recovery) Overload / Overcurrent > 120% of rated load current, Hiccup Mode, Non-Latching (Auto recovery) Over Temperature < 75°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-recovery) Short Circuit Hiccup Mode, Non-Latching (Auto-recovery when the fault is removed). Degree of Protection IP20 (PMH-24V100WCAJ and PMH-24V100WCAU) Protection Against Shock Class I with PE* connection *PE: Primary Earth

PMH Panel Mount Power Supply 24V 100W 1 / PMH-24V100WCA□ All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2015, Rev. 02) Reliability Data MTBF > 700,000 hrs. as per Telcordia SR-332 I/P: 115Vac, O/P: 100% load, Ta: 25°C Expected Cap Life Time 10 years (115Vac & 230Vac, 50% load @ 40°C) Safety Standards / Directives Safety Entry Low Voltage Output non-isolated to PE Output isolated to PE PELV (EN 60335), SELV (EN 60950) SELV (EN 60335), SELV (EN 60950) Electrical Safety SIQ Bauart UL/cUL recognized CB scheme EN 60950-1, EN 60335-1, EN 61558-1, EN 61558-2-16 UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395) IEC 60950-1, IEC 60335-1, IEC 61558-1, IEC 61558-2-16 CE In conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC Material and Parts RoHS Directive 2011/65/EU Compliant Galvanic Isolation Input to Output 4.2KVac Input to Ground 1.5KVac Output to Ground Output non-isolated to PE (common pins connect to PE) (PMH-24V100WCAA, PMH-24V100WCAJ, PMH-24V100WCAL, PMH-24V100WCAH) 1.5KVdc (Output isolated to PE) (PMH-24V100WCAS, PMH-24V100WCAU, PMH-24V100WCAV, PMH-24V100WCAT)

PMH Panel Mount Power Supply 24V 100W 1 / PMH-24V100WCA□ All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2015, Rev. 02) EMC EMC / Emissions CISPR 22, EN 55022, FCC Title 47: Class B, EN 55014-1, EN 61000-6-3 Immunity to EN 55024, EN 61000-6-1, EN 55014-2 Electrostatic Discharge IEC 61000-4-2 Level 4 Criteria A1) Air Discharge: 15kV Contact Discharge: 8kV Radiated Field IEC 61000-4-3 Level 3 Criteria A1) 80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation 1.4GHz-2GHz, 10V/M with 1kHz tone / 80% modulation 2GHz-2.7GHz, 10V/M with 1kHz tone / 80% modulation Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A1) 2kV Surge IEC 61000-4-5 Level 3 Criteria A1) Common Mode3): 2kV Differential Mode4): 1kV Conducted IEC 61000-4-6 Level 3 Criteria A1) 150kHz-80MHz, 10Vrms Power Frequency Magnetic Fields IEC 61000-4-8 Criteria A1) 10A/Meter Voltage Dips and Interruptions IEC 61000-4-11 0% of 100Vac, 20ms 40% of 100Vac, 200ms 70% of 100Vac, 600ms 0% of 100Vac, 6000ms 0% of 240Vac, 20ms 40% of 240Vac, 200ms 70% of 240Vac, 600ms 0% of 240Vac, 6000ms Criteria A1) Criteria B2) Criteria A1) Criteria B2) Criteria A1) Criteria A1) Criteria A1) Criteria B2) Low Energy Pulse Test (Ring Wave) IEC 61000-4-12 Level 3 Criteria A1) Common Mode3): 2kV Differential Mode4): 1kV Harmonic Current Emission IEC/EN 61000-3-2, Class A Voltage Fluctuation and Flicker IEC/EN 61000-3-3 1) Criteria A: Normal performance within the specification limits 2) Criteria B: Temporary degradation or loss of function which is self -recoverable 3) Asymmetrical: Common mode (Line to earth) 4) Symmetrical: Differential mode (Line to line)

PMH Panel Mount Power Supply 24V 100W 1 / PMH-24V100WCA□ All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2015, Rev. 02) Block Diagram Device Descriptions 1) Input & Output terminal block connector 2) DC voltage adjustment potentiometer (22V – 28V) 3) DC OK control LED (Green) PMH-24V100WCAL (V): Front Face PMH-24V100WCAA (S): Terminal Block PMH-24V100WCAJ (U): IP20 Terminal Bl k PMH-24V100WCAH (T): Harness

PMH Panel Mount Power Supply 24V 100W 1 / PMH-24V100WCA□ All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2015, Rev. 02) Dimensions L x W x D: 158 x 97 x 38 mm (6.22 x 3.82 x 1.50 inch) (PMH-24V100WCAA: Terminal Block) Engineering Data Output Load De-rating VS Surrounding Air Temperature Fig. 1 De-rating for Vertical and Horizontal Mounting Orientation -20°C to -30°C de-rate power by 2.0% / °C > 50°C de-rate power by 2.5% / °C Note 1. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1. 2. If the output capacity is not reduced when surrounding air temperature >50 ° C, the device will run into Over Temperature Protection. When activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the d evice in working condition. 3. In order for the device to function in the manner intended, it is also necessary to keep a safety distance of 20mm (0.78 inch) from adjacent units while the device is in operation. 4. Depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! 5. If the device has to be mounted in any other orientation, please contact info@deltapsu.com for more details.

PMH Panel Mount Power Supply 24V 100W 1 / PMH-24V100WCA□ All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2015, Rev. 02) Output Load De-rating VS Input Voltage Assembly & Installation Ⓐ Mounting holes for power supply assembly onto the mounting surface. The power supply shall be mounted on minimum 2 mounting holes using M3 screw minimum 5mm length. Ⓑ This surface belongs to customer’s end system or panel where the power supply is mounted. Ⓒ Connector Fig. 2 Mounting Orientation – Use flexible cable (stranded or solid) with the following sizes: PMH-24V100WCAA (S) PMH-24V100WCAJ (U) PMH-24V100WCAL (V) AWG 20-14 AWG 20-12 AWG 20-12 7mm.  No output power de-rating across the entire input voltage range Side Mounting (Vertical) Base Mounting (Vertical) Side Mounting (Horizontal)

PMH Panel Mount Power Supply 24V 100W 1 / PMH-24V100WCA□ All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2015, Rev. 02) Installation of Mounting Accessories Safety Instructions – To ensure sufficient convection cooling, always maintain a safety distance of ≥ 20mm (0.78 inch) from all ventilated surfaces while the device is in operation. – The device is not recommended to be placed on surface with low thermal conductivity, such as plastics, for example. – Note that the enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning! – Do not touch the terminals while power is being supplied. Risk of electric shock. – Prevent any foreign metal, particles or conductors from entering the device through the openings during installation. It may cause: Electric shock; Safety Hazard; Fire; Product failure – The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lac k of experience and knowledge, unless they have been given supervision or instruction. – Warning: When connecting the device, secure Earth connection before connecting L and N. When disconnecting the device, remove L and N connections before removing the Earth connection. – The device is earthed and must be inaccessible. Accessories L-02: Latch P-03: Bracket These accessories are used to mount the panel mount power supply onto a DIN rail.  Only use M3 screw ≤ 6mm (0.23 inch) through the base mounting holes. This is to keep a safety distance between the screw and internal components.

PMH Panel Mount Power Supply 24V 100W 1 / PMH-24V100WCA□ All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2015, Rev. 02) Functions Start-up Time The time required for the output voltage to reach 90% of its final steady state set value, after the input voltage is applied. Rise Time The time required for the output voltage to change from 10% to 90% of its final steady state set value. Hold-up Time Time between the collapse of the AC input voltage, and the output falling to 95% of its steady state set value.  Graph illustrating the Start-up Time, Rise Time, and Hold-up Time Inrush Current Inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. Dynamic Response The power supply output voltage will remains within ±5% of its steady state value, when subjected to a dynamic load from 0% to 100% of its rated current.  50% duty cycle / 5Hz to 100Hz

PMH Panel Mount Power Supply 24V 100W 1 / PMH-24V100WCA□ All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2015, Rev. 02) Overload & Overcurrent Protections (Auto-Recovery) The power supply’s Overload (OLP) and Overcurrent (OCP) Protections will be activated when output current exceeds 120% of I O (Max load). In such occurrence, the VO will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into “Hiccup mode” (Auto-Recovery). The power supply will recover once the fault condition of the OLP and OCP is removed and I O is back within the specifications. It is not recommended to prolong the duration of I O when it is <120% but >100%, since it may cause damage to the PSU. Short Circuit Protection (Auto-Recovery) The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”, as shown in the illustration in the OLP/OCP section on this page. The power supply wi ll return to normal operation after the short circuit is removed. Overvoltage Protection (Auto-Recovery) The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under “Protections”. Over Temperature Protection (Auto-Recovery) As described in load de-rating section, the power supply also has Over Temperature Protection (OTP). In the event of a higher operating temperature at 100% load, t he power supply will run into OTP when the operating temperature is beyond what is recommended in the de-rating graph. When activated, the output voltage will go into bouncing mode until the temperature drops to its normal operating temperature as recommen ded in the de - rating graph.

PMH Panel Mount Power Supply 24V 100W 1 / PMH-24V100WCA□ All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2015, Rev. 02) Operating Mode  Redundant Operation In order to ensure proper redundant operation for the power supply units (PSUs), the output voltage difference between the two units must be kept at 0.45~0.50V for these 24V supplies. Follow simple steps given below to set them up for the redundant operation: Step 1. Measure output voltage of PSU 1 and PSU 2. If PSU 1 is the master unit, then VO of PSU 1 must be higher than PSU 2. In order to set the output voltage, connect each power supply to 50% of rated load , and set the PSU 1 and PSU 2 output voltage. Step 2. Connect the right DRR-20N (or 20A) module to the power supply units PSU 1 and PSU at Vin 1 & Vin 2, respectively. Step 3. Connect the system load to V out. Please note that output voltage Vout from DRR module will be = VO (output voltage of power supply) – Vdrop* (in DRR module).  Parallel Operation + 2.5A + 2.5A = 7.5A) or current sharing, and thus increasing the power supply and system reliability. Though the PMH-24V100WCA☐ is not designed for current sharing, a good current sharing between two power supplies can be achieved by following simple steps as below (Refer to Fig. 3 for the Connection Diagram). drop will vary from 0.60V to 0.90V (Typical 0.65V) depending on the load current and surrounding air temperature. Fig. 3 Redundancy / Parallel Operation Connection Diagram Step 1. Set output load condition for both supplies at 50% and measure the output voltages. Step 2. Adjust output voltages to the same level or within ± 25mV difference. Step 3. Connect PSU 1 and PSU 2 with the DRR -20A module and measure at Vin 1 & Vin 2 to verify the voltage difference. Ensure the voltages are within ±25mV. Step 4. Output voltage from DRR module V out will be = V O (output voltage of power supply) – Vdrop* (in DRR module).

PMH Panel Mount Power Supply 24V 100W 1 / PMH-24V100WCA□ All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (December 2015, Rev. 02) Others Delta RoHS Compliant Restriction of the usage of hazardous substances The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and electronic equipment. RoHS is the abbreviation for “Restriction of the use of cer tain hazardous substances in electrical and electronic equipment”. This product conforms to this standard. PFC – Norm EN 61000-3-2 Line Current Harmonic content Typically, the input current waveform is not sinusoidal due to the periodical peak charging of the input capacitor. In industrial environment, complying with EN 61000-3-2 is only necessary under special conditions. Complying to this standard can have some technical drawbacks, such as lower efficiency as well as some commercial aspects such as higher purchasing costs. Frequently, the user does not profit from fulfilling this standard, therefore, it is important to know whether it is mandatory to meet this st andard for a specific application.